In traditional energy storage systems, the charging/discharging converter and the cell equalizer are usually two independent subsystems. This paper proposes a converter for energy storage battery applications in which the voltage equalizer is integrated into the charge/discharge converter. The proposed converter reduces the number of components and simplifies the overall system. It can perform automatic voltage balancing among series-connected energy storage cells without any voltage measurement circuit. Two types of the proposed converter are presented. Type A consists of only one active switch, one n-winding coupled inductor, and n diodes. Type B replaces the n diodes of Type A with n active switches to improve efficiency. The relationship between Type A and Type B is similar to that between an asynchronous Buck converter and a synchronous Buck converter. This paper mainly focuses on the analysis and experimental validation of Type B. A prototype with three series-connected energy storage cells was built and tested. Experimental results show that the proposed converter achieves excellent voltage-balancing capability and a well-defined charge/discharge characteristic.
1. Introduction
Secondary batteries, especially lithium-ion cells, are widely used in a broad range of energy storage battery systems, from small portable devices to large-scale applications such as electric vehicles, uninterruptible power supplies, and renewable energy plants. Because the terminal voltage of a single energy storage cell is relatively low, a large number of cells must be connected in series to meet the voltage requirement of practical systems. During repeated charging and discharging, unavoidable differences in capacity, internal resistance, self-discharge rate, and ambient temperature cause the state of charge and terminal voltage of series-connected energy storage cells to become increasingly unbalanced. Without an equalization circuit, the cells with lower capacity may experience repeated overcharge or overdischarge, which shortens their lifetime and reduces the usable capacity of the whole energy storage battery pack. Under severe conditions, such imbalance can even lead to thermal runaway or fire.
Equalization techniques can be generally classified as passive and active. Passive equalization dissipates the excess charge of each cell using resistors, while active equalization transfers charge among cells or between cells and the whole pack by means of capacitors, inductors, or transformers. Passive equalization is widely used because of its low cost and simplicity, but its efficiency is inherently low, and the dissipated heat increases the thermal burden. Active equalization provides higher efficiency and stronger balancing capability, but it usually requires more components, more complex control, and higher cost. Many active equalization topologies have therefore been proposed in the literature, yet passive balancing still dominates in practical low-cost applications.
The balancing path affects the speed and flexibility of equalization. Some topologies realize any-cell-to-any-cell energy transfer, while others transfer energy between any cell and the module. These schemes exhibit excellent balancing speed and flexibility, but their circuits and control algorithms are complicated. Another family of equalizers transfers energy only between adjacent cells, such as Buck-Boost-based equalizers and switched-capacitor equalizers. These circuits are simple and efficient, but when the number of series-connected cells increases, the balancing path becomes long and the balancing energy is dissipated in the transmission path, resulting in a rapid degradation of equalization efficiency.
Transformer-based equalizers can transfer energy between the entire energy storage battery string and each individual cell through a multi-winding transformer. This approach can automatically balance the cell voltages with a relatively simple circuit and open-loop control. Representative examples include the flyback-type and forward-type multi-winding transformer equalizers. Compared with other active equalization techniques, multi-winding transformer-based equalizers have lower complexity, lower cost, and easier implementation. Furthermore, the galvanic isolation provided by the transformer improves reliability. The main drawback is poor scalability, which can be effectively addressed by modularization. Since most power converters already contain magnetic components, reusing the magnetic core for both the power conversion function and the equalization function is an attractive strategy.
In an energy storage battery system, the equalization circuit and the charge/discharge converter are often separate. If the equalization function is integrated into the charge/discharge converter by sharing devices, the number of components, system cost, volume, and complexity can be reduced without significantly compromising performance. Previous works have integrated multi-winding transformer equalizers with Buck or Boost charging circuits by reusing the converter inductor. The proposed converter in this paper follows a similar concept but uses fewer components. It does not need any battery cell voltage measurement to perform equalization because the balancing mechanism is inherently voltage-driven.
The contributions of this work are summarized as follows:
- A new converter that integrates the equalizer and the charge/discharge converter is proposed for series-connected energy storage battery strings.
- Two versions, Type A and Type B, are presented to provide a trade-off between cost and efficiency.
- The steady-state operation, voltage-gain characteristic, and equalization behavior are analyzed in detail.
- A prototype with three lithium-ion cells is built and tested to verify the theoretical analysis.
2. Proposed Converter Topology and Operating Principle
2.1 Type A
The Type A converter is shown below in the form of a conceptual schematic. It consists of one active switch \(S_0\), one \(n\)-winding coupled inductor, \(n\) diodes, and \(n\) series-connected energy storage cells. Each cell \(B_i\) is connected in series with a diode \(D_i\) and a winding \(L_i\). The common magnetic core establishes a mutual coupling among all windings. For simplicity, all windings have the same number of turns and the same self-inductance \(L_m\). The converter is a unidirectional charger because the diodes prevent reverse current flow.
2.2 Type B
The Type B converter replaces each diode \(D_i\) with an active switch \(S_i\). Type B therefore contains \(n+1\) active switches and still uses one magnetic core with \(n\) windings. The control signals are complementary: during the charging process, \(S_0\) is turned on with duty cycle \(D\), while \(S_1\) through \(S_n\) are turned on during the remaining time. The two active-switch groups are driven by the same pair of complementary PWM signals, so no complex modulation is needed. Type B can realize bidirectional energy transfer and has higher efficiency than Type A due to the lower conduction loss of MOSFETs compared with diodes.
2.3 Operating Modes during the Charging Process
In continuous-conduction mode, one switching period of Type B contains five modes. The dead time between the gate signals of \(S_0\) and \(S_i\) is short and its effect on energy transfer is negligible. The key waveforms are described qualitatively as follows: the magnetizing branch voltage alternates between two levels, and the cell currents contain a strong equalization component during the freewheeling interval.
Mode 1 \([t_0 \leq t < t_1]\): Switches \(S_1\)–\(S_n\) are off, and switch \(S_0\) is on. The magnetizing current increases linearly because the input voltage is applied across the series combination of the input source, the coupled inductor, and the cell string. The current flowing into cell \(B_i\) is
$$
i_{Bi}(t) = i_{Bi}(t_0) + \frac{V_{in} – \sum_{j=1}^{n} V_{Bj}}{n^2 L_m + \sum_{j=1}^{n} L_{kj}}(t – t_0)
$$
where \(V_{in}\) is the input voltage, \(V_{Bj}\) is the voltage of the \(j\)-th energy storage cell, \(L_m\) is the magnetizing inductance per winding, and \(L_{kj}\) is the leakage inductance of the \(j\)-th winding. The voltage across each winding in this mode is
$$
V_{Lm_1} = \frac{n L_m \left( V_{in} – \sum_{j=1}^{n} V_{Bj} \right)}{n^2 L_m + \sum_{j=1}^{n} L_{kj}}
$$
Mode 2 \([t_1 \leq t < t_2]\): At \(t=t_1\), \(S_0\) is turned off. The magnetizing current freewheels through the parasitic capacitances of \(S_1\)–\(S_n\). Let \(C_i\) denote the sum of the output capacitance of \(S_i\) and other stray capacitances. The drain-to-source voltage of each \(S_i\) decreases to zero, and then the body diode conducts. The required dead time \(t_d\) must be longer than the discharging time:
$$
t_d > \Delta t = \frac{C_i \left( V_{Lm_1} + V_{Bi} + V_{Di} \right)}{i_{Bi}(t_1)}
$$
In this short interval, the cell currents are assumed to remain constant.
Mode 3 \([t_2 \leq t < t_3]\): At \(t=t_2\), all switches \(S_1\)–\(S_n\) are turned on with zero-voltage switching. The equivalent circuit of the coupled inductor now contains the leakage inductances in series with each cell and the parallel-connected magnetizing branch. Because the windings are coupled, energy is redistributed among the cells. The cell with a lower voltage automatically receives a higher current. The current in cell \(B_i\) can be written as
$$
i_{Bi}(t) = i_{Bi}(t_2) + \frac{V_{Lm_3} – V_{Bi}}{L_{ki}}(t – t_2)
$$
where \(V_{Lm_3}\) is the voltage across the magnetizing branch in this mode. The current through the equivalent magnetizing branch is
$$
i_{Le}(t) = n i_{Bi}(t_2) – \frac{V_{Lm_3}}{L_m}(t – t_2)
$$
Using Kirchhoff’s current law,
$$
i_{Le}(t) = \sum_{j=1}^{n} i_{Bj}(t)
$$
Solving the resulting equations gives
$$
V_{Lm_3} = \frac{\sum_{j=1}^{n} \frac{V_{Bj} L_m}{L_{kj}}}{\sum_{j=1}^{n} \left( 1 + \frac{L_m}{L_{kj}} \right)}
$$
If the leakage inductances are equal and the magnetizing inductance is much larger than the leakage inductances, \(V_{Lm_3}\) is close to the average cell voltage. Thus the differential current in Mode 3 is determined by the deviation of each cell voltage from the average value.
Mode 4 \([t_3 \leq t < t_4]\): At \(t=t_3\), \(S_1\)–\(S_n\) are turned off. After a short dead time, the body diodes supply the freewheeling current. The inductive energy is then partially transferred back to the input source.
Mode 5 \([t_4 \leq t < t_0]\): At \(t=t_4\), \(S_0\) is turned on again. The currents in the windings converge to a common instantaneous value after a brief transient. The duration of Modes 2, 4, and 5 is much shorter than the switching period, so their influence on the average energy transfer is negligible.
Type A has only Modes 1 and 3 because the diodes automatically commutate. However, the steady-state voltage gain and the equalization current expression of Type A are the same as those of Type B, except for the additional diode forward voltage drops.
3. Steady-State Analysis
3.1 Input-Output Characteristic
Ignoring the short transition modes and applying the volt-second balance to the magnetizing inductance gives
$$
\left( V_{in} – \sum_{j=1}^{n} V_{Bj} \right) D T_s + \sum_{j=1}^{n} V_{Bj} (1 – D) T_s = 0
$$
Consequently,
$$
\sum_{j=1}^{n} V_{Bj} = D V_{in}
$$
Equation above shows that the total output voltage of the series-connected energy storage battery string is equal to \(D V_{in}\). Thus the proposed converter has the same voltage-gain characteristic as a Buck converter. This result holds for both Type A and Type B because the transition modes do not contribute to the average voltage.
3.2 Equalization Current Derivation
The average current into cell \(B_i\) during the entire switching period is denoted by \(I_{Bi}\). The average current of all cells is
$$
I_{ave} = \frac{1}{n} \sum_{j=1}^{n} I_{Bj}
$$
The equalization current of cell \(B_i\) is defined as
$$
\Delta I_{Bi} = I_{Bi} – I_{ave}
$$
Because the charging current is identical for all cells in Mode 1, the equalization current is produced solely in Mode 3. From the instantaneous current expression in Mode 3, the average equalization current over the whole switching period is approximated by
$$
\Delta I_{Bi} = \frac{\left( V_{Lm_3} – V_{Bi} \right)(1 – D) T_s}{2 L_{ki}}
$$
For equal leakage inductances \(L_{ki} = L_k\), substituting the expression for \(V_{Lm_3}\) yields the simplified form
$$
\Delta I_{Bi} \approx \frac{(1 – D) T_s}{2 L_k} \left( \frac{1}{n} \sum_{j=1}^{n} V_{Bj} – V_{Bi} \right)
$$
This expression indicates that:
- The equalization current is generated automatically whenever the cell voltages are not identical.
- The magnitude of the equalization current is proportional to the voltage deviation of the cell from the average cell voltage.
- When all cell voltages are equal, the equalization current is zero regardless of the charging current.
- The equalization current can be controlled by the switching frequency and the duty cycle.
- Leakage inductance mismatch affects the magnitude of the individual balancing currents, but it does not prevent the balancing action.
3.3 Influence of Leakage Inductance
A simulation study was performed to evaluate the sensitivity of the equalization current to leakage inductance variations. The simulation conditions are: \(V_{in}=15\ \mathrm{V}\), \(L_m=13\ \mu\mathrm{H}\), \(T_s=20\ \mu\mathrm{s}\), \(D=0.75\), \(V_{B1}=3.8\ \mathrm{V}\), and \(V_{B2}=V_{B3}=3.9\ \mathrm{V}\). The resulting average equalization current in the freewheeling stage was observed for different leakage inductances. The results are summarized in Table 1.
| Case | Leakage inductance configuration | Equalization current, cell 1 | Equalization current, cells 2 and 3 |
|---|---|---|---|
| 1 | \(L_{k1}=L_{k2}=L_{k3}=0.7\ \mu\mathrm{H}\) | Large positive | Equal negative |
| 2 | \(L_{k1}=L_{k2}=L_{k3}=1.0\ \mu\mathrm{H}\) | Medium positive | Equal negative |
| 3 | \(L_{k1}=L_{k2}=L_{k3}=1.3\ \mu\mathrm{H}\) | Small positive | Equal negative |
| 4 | \(L_{k1}=L_{k2}=1.0\ \mu\mathrm{H}, L_{k3}=0.7\ \mu\mathrm{H}\) | Asymmetric | Asymmetric |
| 5 | \(L_{k1}=L_{k2}=1.0\ \mu\mathrm{H}, L_{k3}=1.3\ \mu\mathrm{H}\) | Asymmetric | Asymmetric |
The simulation confirms that increasing the leakage inductance reduces the equalization current. In addition, a 30% mismatch in leakage inductance clearly changes the distribution of the balancing currents. However, the balancing action remains effective as long as a voltage difference exists.
4. Experimental Verification
4.1 Prototype and Test Setup
To validate the proposed converter, a Type B prototype with three series-connected energy storage cells was built. Three commercial lithium-ion cells with a nominal voltage of 3.6 V were used. The key components and parameters are listed in Table 2.
| Component / Parameter | Specification |
|---|---|
| Switches \(S_0\)–\(S_3\) | STP220N6F7, \(R_{DS(on)}=2.40\ \mathrm{m}\Omega\) |
| Output capacitor \(C_0\) | Multilayer ceramic capacitor, 22 µF × 3 |
| Magnetizing inductance \(L_m\) | 12.2 μH |
| Switching frequency \(f_s\) | 50–250 kHz |
| Number of windings | 3 |
| Battery cells | NCR21700T lithium-ion cells |
The experimental platform is shown below. It consists of a bidirectional programmable DC power supply, a programmable DC electronic load, a three-cell battery module, a signal generator, an oscilloscope, and the proposed equalization converter. The control signals are generated by a microcontroller using a single complementary PWM pair.

4.2 Charging Current Waveforms and Equalization Current
Three experiments were performed to observe the charging current waveforms under balanced and unbalanced cell voltages. The input voltage was set to 12.3 V, and the switching frequency was 100 kHz. The cell voltages for the three experiments are listed in Table 3.
| Experiment | \(V_{B1}\) | \(V_{B2}\) | \(V_{B3}\) |
|---|---|---|---|
| 1 | 3.80 V | 3.80 V | 3.75 V |
| 2 | 3.80 V | 3.80 V | 3.85 V |
| 3 | 3.80 V | 3.80 V | 3.80 V |
The measured average charging currents in the freewheeling stage are shown in Table 4. In Experiment 1, cell 3 has the lowest voltage and receives the highest average current. In Experiment 2, cell 3 has the highest voltage and receives the lowest average current. In Experiment 3, all cells receive the same average current.
| Experiment | \(I_{ave1}\) | \(I_{ave2}\) | \(I_{ave3}\) |
|---|---|---|---|
| 1 | 1.56 A | 1.56 A | 1.67 A |
| 2 | 1.46 A | 1.46 A | 1.42 A |
| 3 | 1.43 A | 1.43 A | 1.43 A |
The average equalization current over the entire switching period can be calculated as
$$
\Delta I_{Bi} = \left( I_{avei} – \frac{I_{ave1}+I_{ave2}+I_{ave3}}{3} \right) D
$$
Using \(D=0.75\), the resulting equalization currents are summarized in Table 5.
| Experiment | \(\Delta I_{B1}\) | \(\Delta I_{B2}\) | \(\Delta I_{B3}\) |
|---|---|---|---|
| 1 | −22 mA | −22 mA | 44 mA |
| 2 | 8 mA | 8 mA | −16 mA |
| 3 | 0 mA | 0 mA | 0 mA |
The experimental results agree with the theoretical conclusion: the lower the cell voltage, the larger the charging current in the freewheeling stage. Consequently, the cell voltages are automatically equalized over time. When all cell voltages are equal, the equalization current is zero and does not depend on the charging current.
4.3 Input-Output Characteristic
To measure the voltage-gain characteristic, three 4.7 μF film capacitors were used in place of the battery cells. The duty cycle was fixed at \(D=0.7\). The input voltage was varied from 11 V to 29 V, and the total output voltage (the sum of the three capacitor voltages) was recorded. The measured values and the calculated values from \(V_{out} = D V_{in}\) are shown in Table 6.
| \(V_{in}\) (V) | Calculated \(V_{out}\) (V) | Measured \(V_{out}\) (V) |
|---|---|---|
| 11 | 7.7 | 7.6 |
| 13 | 9.1 | 9.0 |
| 15 | 10.5 | 10.4 |
| 17 | 11.9 | 11.8 |
| 19 | 13.3 | 13.2 |
| 21 | 14.7 | 14.6 |
| 23 | 16.1 | 16.0 |
| 25 | 17.5 | 17.4 |
| 27 | 18.9 | 18.8 |
| 29 | 20.3 | 20.2 |
The measured results are in good agreement with the calculated values, confirming that the proposed converter behaves like a Buck converter in terms of its input-output characteristic.
4.4 Voltage Equalization Tests
Two charging experiments were carried out to test the actual voltage-balancing performance of the proposed converter.
Test 1: Before charging, the initial voltages of the three energy storage cells were \(V_{B1}=3.220\ \mathrm{V}\), \(V_{B2}=3.250\ \mathrm{V}\), and \(V_{B3}=3.282\ \mathrm{V}\). The standard deviation of the cell voltages was 25.3 mV. The converter was operated at 100 kHz with a constant-current/constant-voltage charging profile of 1 A and 12.3 V. After 7200 s of charging, the final voltages were \(V_{B1}=4.105\ \mathrm{V}\), \(V_{B2}=4.109\ \mathrm{V}\), and \(V_{B3}=4.114\ \mathrm{V}\). The standard deviation was reduced to 3.6 mV.
Test 2: A more severe initial imbalance was created: \(V_{B1}=3.234\ \mathrm{V}\), \(V_{B2}=3.121\ \mathrm{V}\), and \(V_{B3}=2.735\ \mathrm{V}\). The range of the initial voltages was 499.0 mV and the standard deviation was 213.6 mV. With a two-stage constant-current charging profile of 4.8 A followed by 1.6 A at 100 kHz, the voltages after 5200 s were \(V_{B1}=4.109\ \mathrm{V}\), \(V_{B2}=4.092\ \mathrm{V}\), and \(V_{B3}=4.083\ \mathrm{V}\). The standard deviation was reduced to 10.6 mV. The detailed voltage standard deviation evolution is summarized in Table 7.
| Test | Initial standard deviation | Final standard deviation | Charging time |
|---|---|---|---|
| 1 | 25.3 mV | 3.6 mV | 7200 s |
| 2 | 213.6 mV | 10.6 mV | 5200 s |
These results demonstrate that the proposed converter can significantly suppress voltage imbalance during the charging process without any dedicated cell-voltage measurement or feedback control.
4.5 Efficiency
The efficiency of the Type B prototype was measured with an input voltage of 15 V. The measured efficiency as a function of the charging power is given in Table 8. The maximum efficiency reached 94.7% at an output power of 13.5 W.
| Charging power (W) | Efficiency (%) |
|---|---|
| 5 | 88.2 |
| 10 | 92.6 |
| 13.5 | 94.7 |
| 20 | 93.1 |
| 25 | 90.4 |
| 30 | 86.8 |
5. Comparison with Existing Techniques
The proposed integrated topology is compared with several existing charge/equalization converters in Table 9. The comparison considers the number of active switches, magnetic cores, windings, diodes, capacitors, and the estimated component cost for a three-cell energy storage battery string. The cost indications are based on typical unit prices of commercial components: MOSFET $0.2, gate-driver IC $0.8, diode $0.15, capacitor $0.2, winding $0.2, and magnetic core $0.9.
| Topology | Active switches | Magnetic cores (core, windings) | Diodes | Capacitors | Cost for \(n=3\) |
|---|---|---|---|---|---|
| Voltage-multiplier Boost [Ref] | 1 | 1 (1, 1) | \(2n\) | \(n\) | 2.8 |
| Forward-flyback resonant inverter [Ref] | 1 | 1 (1, 2) | \(2n\) | \(n+1\) | 3.2 |
| Multi-stacked Buck-Boost Sepic [Ref] | 1 | \(n+1\) \((n+1, n+1)\) | \(n\) | \(n\) | 5.65 |
| Multiwinding-transformer Buck [Ref] | 1 | 1 (1, \(n+1\)) | \(n+1\) | 0 | 2.5 |
| Multiwinding-transformer Boost [Ref] | 1 | 1 (1, \(n+1\)) | \(n+1\) | 0 | 2.5 |
| Proposed Type A | 1 | 1 (1, \(n\)) | \(n\) | 0 | 2.15 |
| Proposed Type B | \(n+1\) | 1 (1, \(n\)) | 0 | 0 | 2.3 |
The proposed Type A uses the fewest diodes and one less winding than the previous transformer-based integrated converters, leading to a lower cost. Type B has a slightly higher cost due to the additional active switches, but it offers higher efficiency and bidirectional capability. Type A is preferred for low-cost unidirectional charging applications where efficiency is not critical; Type B is preferred when efficiency and bidirectional power flow are important.
6. Conclusion
This paper has presented a converter with automatic voltage-balancing capability for series-connected energy storage battery systems. The equalization function is integrated into the charge/discharge converter by reusing a multi-winding coupled inductor, thereby reducing the component count and simplifying the system. The proposed converter does not need any voltage measurement circuit to achieve voltage balance; the balancing current is generated inherently by the voltage difference among cells.
Two topologies, Type A and Type B, were described. Type A has one active switch, one coupled inductor, and \(n\) diodes, while Type B replaces the diodes with active switches. Their relationship is analogous to that between asynchronous and synchronous Buck converters. The steady-state analysis shows that the voltage gain of the proposed converter is identical to that of a Buck converter. The equalization current is proportional to the deviation of the cell voltage from the average cell voltage and can be controlled by the switching frequency and duty cycle. The leakage inductance influences the magnitude of the equalization current but does not impair the balancing capability.
Experimental tests on a three-cell lithium-ion battery string verified the theoretical predictions. The voltage standard deviation was reduced from 25.3 mV to 3.6 mV in one test and from 213.6 mV to 10.6 mV in another test with a more severe initial imbalance. The measured efficiency reached 94.7%. These results confirm that the proposed converter is a promising low-complexity and low-cost solution for energy storage battery equalization.