In my research, I focused on the design, modeling, control, and experimental validation of three-phase solar inverters for photovoltaic grid-connected applications. Solar energy is one of the most important renewable resources, and photovoltaic power generation has become a central technology for reducing dependence on fossil fuels. Among the many stages in a photovoltaic system, the grid-connected solar inverter plays a decisive role because it converts the DC power produced by photovoltaic modules into AC power that matches the grid in frequency, phase, and amplitude. I studied the mathematical model of the photovoltaic cell, maximum power point tracking, space vector pulse width modulation, double-loop control, repetitive control, hardware implementation, and software development. The target of my work was to improve the stability, dynamic response, conversion efficiency, and power quality of three-phase solar inverters.
The design of a grid-connected photovoltaic system is not only a power electronics problem but also a control problem. A solar inverter must track the maximum power point of the photovoltaic array, synchronize with the utility grid, regulate the DC-link voltage, and inject a low-distortion current. In my design, I used a two-stage structure: a Boost converter for voltage boosting and maximum power point tracking, followed by a three-phase full-bridge voltage-source inverter. The inverter was controlled with space vector pulse width modulation, and the current loop combined proportional-integral control with repetitive control. I used a digital signal processor as the main controller and verified the design through simulation and experimental prototypes.
1. Photovoltaic Cell Model and Output Characteristics
To design a reliable solar inverter, I first needed an accurate model of the photovoltaic source. The single-diode equivalent circuit is widely used because it captures the main physical behavior without excessive complexity. In my model, the photovoltaic cell is represented by a current source in parallel with a diode, a shunt resistance, and a series resistance. The output current can be expressed as:
$$I = I_{ph} – I_0 \left( \exp\left( \frac{q(U + I R_s)}{n k T} \right) – 1 \right) – \frac{U + I R_s}{R_{sh}}$$
where \(I_{ph}\) is the photogenerated current, \(I_0\) is the diode reverse saturation current, \(q\) is the electron charge, \(U\) is the terminal voltage, \(R_s\) is the series resistance, \(R_{sh}\) is the shunt resistance, \(n\) is the diode ideality factor, \(k\) is the Boltzmann constant, and \(T\) is the cell temperature. In many practical designs, the shunt resistance is assumed to be very large, so the last term can be neglected. The simplified model then becomes:
$$I = I_{ph} – I_0 \left( \exp\left( \frac{q(U + I R_s)}{n k T} \right) – 1 \right)$$
I used this model to study how irradiance and temperature affect the current-voltage and power-voltage curves. The output power of a photovoltaic cell is highly nonlinear. For a given irradiance and temperature, there is a unique maximum power point. If the operating voltage is below or above this point, the extracted power decreases. This behavior is the reason why maximum power point tracking is essential in all solar inverters.
| Parameter | Symbol | Typical Value in My Study |
|---|---|---|
| Open-circuit voltage | \(V_{oc}\) | 44.8 V |
| Short-circuit current | \(I_{sc}\) | 5.35 A |
| Maximum power | \(P_{max}\) | 200 W |
| Voltage at maximum power | \(V_{mp}\) | 36.2 V |
| Current at maximum power | \(I_{mp}\) | 5.52 A |
| Temperature coefficient of \(V_{oc}\) | \(\beta\) | -0.32 %/°C |
| Temperature coefficient of \(I_{sc}\) | \(\alpha\) | 0.05 %/°C |
The irradiance mainly affects the current, while the temperature mainly affects the voltage. When irradiance increases, the short-circuit current increases almost proportionally, and the maximum power point moves to a higher current. When temperature increases, the open-circuit voltage decreases, and the maximum power point moves to a lower voltage. Therefore, a fixed operating voltage cannot guarantee maximum power extraction. The solar inverter must continuously adjust its operating point. This is especially important for three-phase solar inverters that are connected to a low-voltage or medium-voltage grid.
2. Maximum Power Point Tracking with Fuzzy Control
Maximum power point tracking is one of the most important functions in photovoltaic solar inverters. I evaluated several classical methods, including constant voltage, perturb and observe, and incremental conductance. The incremental conductance method is based on the derivative of power with respect to voltage:
$$\frac{dP}{dU} = I + U \frac{dI}{dU}$$
At the maximum power point, the derivative is zero:
$$\frac{dI}{dU} = -\frac{I}{U}$$
The operating point is to the left of the maximum power point when:
$$\frac{dI}{dU} > -\frac{I}{U}$$
and to the right when:
$$\frac{dI}{dU} < -\frac{I}{U}$$
Although incremental conductance can be accurate, it requires precise sensing and can be computationally intensive. To improve the dynamic performance of my solar inverters, I used a fuzzy logic controller for maximum power point tracking. Fuzzy control does not require an exact mathematical model of the photovoltaic array, and it can handle nonlinearity and parameter variations well.
I defined the slope of the power-voltage curve and its change as the input variables. The output was the duty cycle increment for the Boost converter. The linguistic variables were negative big, negative small, zero, positive small, and positive big. The rule base contained twenty-five rules. A representative rule is: if the slope is positive big and the slope change is negative small, then the duty cycle increment is positive small. The fuzzy inference used triangular and trapezoidal membership functions. The defuzzified output adjusted the duty cycle of the Boost converter so that the photovoltaic array operated near the maximum power point.
| Slope \(E\) | Change of Slope \(EC\) | Duty Cycle Change \(\Delta D\) |
|---|---|---|
| NB | NB | NB |
| NB | NS | NS |
| NB | Z | NB |
| NB | PS | PS |
| NB | PB | PB |
| NS | NB | NB |
| NS | NS | NS |
| NS | Z | NS |
| NS | PS | PS |
| NS | PB | PB |
| Z | NB | NB |
| Z | NS | NS |
| Z | Z | Z |
| Z | PS | PS |
| Z | PB | PB |
| PS | NB | NB |
| PS | NS | NS |
| PS | Z | NS |
| PS | PS | PS |
| PS | PB | PB |
| PB | NB | NB |
| PB | NS | NS |
| PB | Z | NB |
| PB | PS | PS |
| PB | PB | PB |
I coupled the fuzzy maximum power point tracker with a Boost converter. The Boost converter relations are:
$$U_o = \frac{U_i}{1 – D}$$
$$I_o = (1 – D) I_i$$
$$R_{eq} = \frac{U_i}{I_i} = (1 – D)^2 R_L$$
By adjusting the duty cycle \(D\), the equivalent input resistance of the Boost converter can be matched to the photovoltaic source resistance. When the equivalent resistance equals the internal resistance of the photovoltaic array, maximum power is transferred. In my simulation, the fuzzy controller reached the maximum power point quickly and maintained stable operation even when irradiance changed abruptly. The output power ripple was small, and the tracking speed was better than that of the conventional incremental conductance method.
3. Three-Phase Grid-Connected Inverter Topology
For the power conversion stage, I selected a voltage-source three-phase full-bridge inverter. The DC side is connected to a large capacitor, so the input appears as a voltage source. The AC side is connected to the grid through an LC filter. The main circuit contains six insulated-gate bipolar transistors, each with an antiparallel diode. The LC filter attenuates switching harmonics and helps the solar inverter inject a nearly sinusoidal current into the grid.

The topology I used can be described by the switching function \(S_k\), where \(k = a, b, c\). When the upper switch of a phase leg is on, \(S_k = 1\). When the lower switch is on, \(S_k = 0\). The phase-to-midpoint voltages are:
$$u_{ao} = \frac{U_{dc}}{3}(2S_a – S_b – S_c)$$
$$u_{bo} = \frac{U_{dc}}{3}(2S_b – S_a – S_c)$$
$$u_{co} = \frac{U_{dc}}{3}(2S_c – S_a – S_b)$$
The three-phase currents satisfy Kirchhoff’s current law, and the neutral point voltage is determined by the balanced grid assumption. For the LC filter, the inductor current and capacitor voltage are related by:
$$L_1 \frac{di_{Lk}}{dt} + R_1 i_{Lk} = u_{ko} – u_{ck}$$
$$C \frac{du_{ck}}{dt} = i_{Lk} – i_{sk}$$
where \(i_{Lk}\) is the inductor current, \(u_{ck}\) is the capacitor voltage, and \(i_{sk}\) is the grid current. These equations form the basis of the mathematical model used in my control design.
4. Coordinate Transformation and Mathematical Model
To simplify the control of three-phase solar inverters, I used Clark and Park transformations. The Clark transformation converts the three-phase stationary frame \(abc\) into the two-phase stationary frame \(\alpha\beta\):
$$\begin{bmatrix} i_\alpha \\ i_\beta \end{bmatrix} = \frac{2}{3} \begin{bmatrix} 1 & -\frac{1}{2} & -\frac{1}{2} \\ 0 & \frac{\sqrt{3}}{2} & -\frac{\sqrt{3}}{2} \end{bmatrix} \begin{bmatrix} i_a \\ i_b \\ i_c \end{bmatrix}$$
The inverse Clark transformation is:
$$\begin{bmatrix} i_a \\ i_b \\ i_c \end{bmatrix} = \begin{bmatrix} 1 & 0 \\ -\frac{1}{2} & \frac{\sqrt{3}}{2} \\ -\frac{1}{2} & -\frac{\sqrt{3}}{2} \end{bmatrix} \begin{bmatrix} i_\alpha \\ i_\beta \end{bmatrix}$$
The Park transformation converts the stationary \(\alpha\beta\) frame into the synchronously rotating \(dq\) frame:
$$\begin{bmatrix} i_d \\ i_q \end{bmatrix} = \begin{bmatrix} \cos\theta & \sin\theta \\ -\sin\theta & \cos\theta \end{bmatrix} \begin{bmatrix} i_\alpha \\ i_\beta \end{bmatrix}$$
After applying these transformations, the model of the three-phase solar inverter in the \(dq\) frame becomes:
$$L_1 \frac{di_{Ld}}{dt} = u_d – u_{sd} – R_1 i_{Ld} + \omega L_1 i_{Lq}$$
$$L_1 \frac{di_{Lq}}{dt} = u_q – u_{sq} – R_1 i_{Lq} – \omega L_1 i_{Ld}$$
$$C \frac{du_{Cd}}{dt} = i_{Ld} – i_{sd} + \omega C u_{Cq}$$
$$C \frac{du_{Cq}}{dt} = i_{Lq} – i_{sq} – \omega C u_{Cd}$$
where \(\omega\) is the grid angular frequency. The cross-coupling terms \(\omega L_1 i_{Lq}\), \(\omega L_1 i_{Ld}\), \(\omega C u_{Cq}\), and \(\omega C u_{Cd}\) are compensated by the current controllers. This decoupled model allowed me to design the current loops independently.
| Frame | Variables | Main Use in My Design |
|---|---|---|
| \(abc\) | Three-phase AC quantities | Physical measurements and grid interface |
| \(\alpha\beta\) | Two-phase stationary quantities | Space vector modulation and Clark transformation |
| \(dq\) | Two-phase rotating DC quantities | PI control and repetitive control |
5. Space Vector Pulse Width Modulation
Space vector pulse width modulation is widely used in three-phase solar inverters because it provides a higher DC-link utilization than sinusoidal pulse width modulation. In my design, the eight switching states produced by the six switches correspond to eight voltage vectors: six active vectors and two zero vectors. The active vectors divide the \(\alpha\beta\) plane into six sectors. For a reference voltage vector \(U_{ref}\), the volt-second balance equation is:
$$U_{ref} T_s = U_x T_x + U_y T_y + U_0 T_0 + U_7 T_7$$
where \(T_s\) is the switching period, \(T_x\) and \(T_y\) are the dwell times of the adjacent active vectors, and \(T_0\) and \(T_7\) are the dwell times of the zero vectors. In sector I, the active vectors are \(U_4\) and \(U_6\). The dwell times are:
$$T_x = \frac{\sqrt{3} T_s}{U_{dc}} \left( \frac{\sqrt{3}}{2} U_\alpha – \frac{1}{2} U_\beta \right)$$
$$T_y = \frac{\sqrt{3} T_s}{U_{dc}} U_\beta$$
To avoid overmodulation, the sum of the active vector times must not exceed the switching period:
$$T_x + T_y \leq T_s$$
I used a seven-segment switching sequence to minimize harmonic distortion and switching losses. The sector is determined by the signs of \(U_\beta\), \(\sqrt{3}U_\alpha – U_\beta\), and \(-\sqrt{3}U_\alpha – U_\beta\). The switching times for the three phase legs are calculated from the active vector times and the zero-vector time. The maximum phase voltage amplitude with space vector pulse width modulation is:
$$U_{max} = \frac{U_{dc}}{\sqrt{3}}$$
This is about 15.47% higher than the maximum amplitude obtained with sinusoidal pulse width modulation. Therefore, space vector pulse width modulation improves the DC-link utilization of my solar inverters.
| Sector | Active Vectors | Switching Sequence |
|---|---|---|
| I | \(U_4, U_6\) | \(0-4-6-7-7-6-4-0\) |
| II | \(U_2, U_6\) | \(0-2-6-7-7-6-2-0\) |
| III | \(U_2, U_3\) | \(0-2-3-7-7-3-2-0\) |
| IV | \(U_1, U_3\) | \(0-1-3-7-7-3-1-0\) |
| V | \(U_1, U_5\) | \(0-1-5-7-7-5-1-0\) |
| VI | \(U_4, U_5\) | \(0-4-5-7-7-5-4-0\) |
6. Control Strategy for Solar Inverters
For the grid-connected operation of three-phase solar inverters, I used a voltage-oriented vector control strategy. The grid voltage vector is aligned with the \(d\)-axis of the synchronous rotating frame. Therefore, the \(d\)-axis current controls active power, and the \(q\)-axis current controls reactive power. For unity power factor operation, the \(q\)-axis current reference is set to zero. The active and reactive powers are:
$$P = \frac{3}{2} (u_d i_d + u_q i_q)$$
$$Q = \frac{3}{2} (u_q i_d – u_d i_q)$$
With \(u_q = 0\), these simplify to:
$$P = \frac{3}{2} u_d i_d$$
$$Q = -\frac{3}{2} u_d i_q$$
Thus, by controlling \(i_d\) and \(i_q\), I could independently regulate active and reactive power. The outer voltage loop regulates the DC-link voltage and generates the \(d\)-axis current reference. The inner current loop tracks the \(d\)-axis and \(q\)-axis current references. The PI controllers with decoupling terms are:
$$u_d^* = -\left( k_p + \frac{k_i}{s} \right) (i_d^* – i_d) + u_{sd} – \omega L_1 i_{Lq}$$
$$u_q^* = -\left( k_p + \frac{k_i}{s} \right) (i_q^* – i_q) + u_{sq} + \omega L_1 i_{Ld}$$
Although PI control is simple and reliable, it cannot eliminate periodic disturbances caused by dead time, sensor errors, and grid voltage harmonics. Therefore, I added a repetitive controller in parallel with the PI controller. Repetitive control is based on the internal model principle. For a periodic signal with period \(T\), the internal model is:
$$G(z) = \frac{z^{-N}}{1 – Q(z) z^{-N}}$$
where \(N\) is the number of samples per fundamental period, and \(Q(z)\) is a low-pass filter or a constant slightly less than one. In my design, \(Q(z) = 0.95\). The repetitive controller learns the periodic error from the previous cycle and adds a correction to the next cycle. This greatly reduces harmonic distortion in the grid current. The stability condition for the repetitive controller is:
$$|Q(z) – G_c(z) G_p(z)| < 1$$
where \(G_c(z)\) is the compensator and \(G_p(z)\) is the plant. The compensator includes a gain, a phase-lead term, and a low-pass filter. The combination of PI and repetitive control gave fast transient response and excellent steady-state accuracy. This is especially important for solar inverters connected to weak grids.
| Control Method | Advantages | Limitations | Role in My Design |
|---|---|---|---|
| PI control | Simple, fast, robust | Poor rejection of periodic disturbances | Main current and voltage regulation |
| Repetitive control | Excellent harmonic suppression | Slow dynamic response | Parallel compensation of periodic errors |
| PI + repetitive control | Fast response and low THD | More complex tuning | Final current control strategy |
7. Simulation Model and Results
I built a simulation model of the complete three-phase photovoltaic grid-connected system. The main parameters are listed in the table below. The DC-link voltage was set to 700 V, the grid line voltage was 380 V, the rated power was 10 kVA, the switching frequency was 10.5 kHz, and the grid frequency was 50 Hz. The LC filter inductance was 2.25 mH, and the filter capacitance was 10.96 \(\mu\)F. The simulation included the photovoltaic array, the fuzzy maximum power point tracker, the Boost converter, the three-phase inverter, the LC filter, and the grid.
| Parameter | Value |
|---|---|
| Rated power | 10 kVA |
| DC-link voltage | 700 V |
| Grid voltage | 380 V line-to-line |
| Grid frequency | 50 Hz |
| Switching frequency | 10.5 kHz |
| Filter inductance | 2.25 mH |
| Filter capacitance | 10.96 \(\mu\)F |
| DC-link capacitance | 40.9 \(\mu\)F minimum |
First, I tested the system with only PI current control. The grid current was synchronized with the grid voltage, and the power factor was close to unity. However, the total harmonic distortion of the grid current was 7.75%, which exceeded the 5% limit specified by common grid codes. The active power fluctuated between 8 kW and 11 kW, and the reactive power fluctuated between -2 kvar and 2 kvar. The PI controller alone could not sufficiently reject the periodic disturbances introduced by the dead time and the nonlinear load.
Then I added the repetitive controller in parallel with the PI controller. The improvement was significant. The grid current became smoother, and the total harmonic distortion decreased to 3.18%, which satisfied the grid requirement. The active power was maintained near 10 kW, and the reactive power was close to zero. The grid current and grid voltage were nearly in phase. The repetitive controller effectively suppressed the periodic harmonics and improved the quality of the power injected by the solar inverters.
| Control Strategy | THD of Grid Current | Active Power Ripple | Reactive Power Ripple | Grid Compliance |
|---|---|---|---|---|
| PI only | 7.75% | 8–11 kW | -2–2 kvar | Not satisfied |
| PI + repetitive | 3.18% | Near 10 kW | Near 0 kvar | Satisfied |
I also verified the space vector pulse width modulation module. The sector selection followed the expected sequence, and the switching times formed a saddle-like waveform. The PWM pulses had complementary signals for the upper and lower switches with a dead time of about 4 \(\mu\)s. This dead time prevented shoot-through in the inverter legs. The three-phase output voltages were balanced and separated by 120 degrees.
8. Hardware Design of the Solar Inverters
The hardware of my three-phase solar inverter prototype included the main power circuit, the gate drive circuit, the sampling circuits, the zero-crossing detection circuit, the protection circuit, and the power supply circuit. I used a DSP as the main controller. The DSP generated the space vector pulse width modulation signals, sampled the voltages and currents, performed the coordinate transformations, executed the PI and repetitive control algorithms, and managed the protection logic.
For the power switches, I selected insulated-gate bipolar transistors because they combine low conduction losses with high blocking voltage. The DC-link capacitor was chosen to buffer the energy exchange between the photovoltaic array and the grid. The minimum capacitance was calculated from:
$$C_{dc} \geq \frac{I_N \Delta t}{2 \Delta U_{dc}}$$
where \(I_N\) is the rated phase current, \(\Delta t\) is the switching period, and \(\Delta U_{dc}\) is the allowed voltage ripple. With a 15% voltage ripple, the minimum capacitance was about 40.9 \(\mu\)F. In practice, I selected a larger capacitor to provide margin. The LC filter inductance was designed to limit the current ripple to 15%:
$$L_0 = \frac{V_{g,max}(V_{dc} – V_{g,max})}{\Delta i V_{dc} T}$$
The calculated inductance was about 1.26 mH, but I selected 2.8 mH to reduce ripple further and improve current quality. The filter capacitance was chosen to keep the reactive power below 5% of the rated power. I selected 10 \(\mu\)F.
| Component | Design Consideration | Selected Value or Device |
|---|---|---|
| Power switch | High voltage, high current, fast switching | IGBT, 1200 V, 20 A |
| DC-link capacitor | Voltage ripple and energy buffer | Electrolytic capacitor, > 40.9 \(\mu\)F |
| Filter inductor | Current ripple limitation | 2.8 mH |
| Filter capacitor | Reactive power limitation | 10 \(\mu\)F |
| Controller | Fast computation and PWM generation | DSP with 150 MHz clock |
| Gate driver | Isolation and protection | IR2235 with bootstrap capacitor |
| Current sensor | Galvanic isolation and accuracy | Hall-effect current sensor |
The gate drive circuit used an IR2235 driver. It provided three high-side and three low-side outputs, compatible with TTL and CMOS logic. The bootstrap capacitor was 4.7 \(\mu\)F. I also used optocouplers to isolate the DSP from the gate driver. This protection was important because a fault in the power stage could otherwise damage the controller. The current sampling was performed by Hall-effect sensors, and the voltage sampling used resistor dividers, filters, and operational amplifiers. The zero-crossing detection circuit produced a square wave synchronized with the grid voltage. This signal was fed to the capture input of the DSP for phase-locked loop operation. The protection circuits monitored overvoltage and overcurrent conditions and could shut down the PWM outputs immediately.
9. Software Design
The software for the solar inverters was developed in a DSP integrated development environment. The main program initialized the system, configured the input/output ports, set up the analog-to-digital converter, configured the event manager, and enabled the interrupts. The interrupt service routine performed the analog-to-digital sampling, the phase and frequency adjustment, the maximum power point tracking, the coordinate transformations, the PI and repetitive control calculations, and the space vector pulse width modulation duty-cycle updates.
The phase-locked loop was implemented with a capture interrupt. When a rising edge of the grid voltage synchronization signal was detected, the timer value was recorded. The difference between two consecutive rising edges gave the grid period. If the calculated frequency was within the acceptable range, the sine table pointer was reset, and the frequency value was updated. This ensured that the output current of the solar inverters remained synchronized with the grid voltage.
| Software Module | Main Function | Implementation Method |
|---|---|---|
| Main program | Initialization and background loop | Register and peripheral setup |
| Interrupt service | Real-time control | PWM underflow interrupt |
| ADC sampling | Voltage and current acquisition | Sequential sampling with DMA |
| PLL | Grid synchronization | Capture interrupt and timer |
| MPPT | Maximum power tracking | Fuzzy logic and duty cycle update |
| Current control | PI and repetitive control | \(dq\) frame calculation |
| SVPWM | PWM generation | Sector judgment and time calculation |
10. Experimental Results
I built a 1 kW experimental prototype to validate the design. The prototype included a photovoltaic panel, a battery for stable DC input, a Boost converter, a three-phase full-bridge inverter, an LC filter, a DSP control board, gate drivers, sampling circuits, and protection circuits. I used an oscilloscope to observe the key waveforms.
The synchronization signal from the zero-crossing detection circuit was compared with the grid voltage. The square wave was aligned with the grid voltage zero crossings, which confirmed that the phase-locked loop was working correctly. The PWM drive signals for the upper and lower switches of the same phase leg were complementary, with a dead time of about 4 \(\mu\)s. The drive signals for different phase legs were separated by 120 degrees. The three-phase output voltages were balanced and showed the expected phase relationship.
The grid voltage and the grid current were displayed together. The current waveform was nearly sinusoidal, and the phase difference between the voltage and current was very small. The harmonic distortion was low, and the solar inverters injected power into the grid with unity power factor. These experimental results confirmed the feasibility of the proposed control strategy and hardware design. The fuzzy maximum power point tracker also performed well under changing irradiance. When the irradiance increased, the output power increased quickly, and the operating point remained close to the maximum power point.
| Experimental Item | Observed Result | Conclusion |
|---|---|---|
| Grid synchronization | Square wave aligned with zero crossings | PLL works correctly |
| PWM dead time | About 4 \(\mu\)s | Shoot-through prevented |
| Three-phase output | Balanced, 120° apart | Inverter switching correct |
| Grid current | Nearly sinusoidal, in phase with voltage | Unity power factor achieved |
| MPPT response | Fast tracking under irradiance change | Fuzzy MPPT effective |
11. Discussion
The results of my study show that three-phase solar inverters can achieve high performance when the design combines an appropriate power topology, an accurate mathematical model, a robust maximum power point tracker, and an effective current control strategy. The fuzzy logic maximum power point tracker was particularly suitable because the photovoltaic array is nonlinear and its parameters vary with irradiance and temperature. The space vector pulse width modulation provided a higher DC-link utilization than sinusoidal pulse width modulation. The voltage-oriented vector control allowed independent control of active and reactive power. The parallel combination of PI control and repetitive control gave both fast dynamic response and low steady-state harmonic distortion.
For solar inverters connected to the grid, power quality is a critical issue. Grid codes often require the total harmonic distortion of the injected current to be below 5%. In my simulation, PI control alone produced a total harmonic distortion of 7.75%, which was unacceptable. After adding repetitive control, the total harmonic distortion dropped to 3.18%. This improvement was achieved without sacrificing the transient response because the PI controller handled sudden changes while the repetitive controller corrected periodic errors. The active power remained close to the rated value, and the reactive power was almost zero. This confirms that the hybrid control strategy is well suited for three-phase solar inverters.
The hardware design also proved to be practical. The DC-link capacitor and LC filter values were selected based on analytical formulas and then verified by simulation and experiment. The gate driver with bootstrap capacitors and optocoupler isolation protected the DSP and ensured reliable switching. The Hall-effect current sensors provided accurate current feedback. The zero-crossing detection circuit and the digital phase-locked loop maintained synchronization even when the grid frequency varied slightly. The protection circuits prevented damage during overvoltage and overcurrent events. The experimental prototype operated stably and produced a clean grid current.
12. Conclusion
In my research, I designed and analyzed three-phase solar inverters for photovoltaic grid connection. I developed a single-diode photovoltaic model, studied its output characteristics, and implemented fuzzy logic maximum power point tracking with a Boost converter. I derived the mathematical model of the three-phase voltage-source inverter in the \(abc\), \(\alpha\beta\), and \(dq\) frames. I used space vector pulse width modulation to generate the switching signals and voltage-oriented vector control to regulate the grid current. I combined PI control with repetitive control to reduce harmonic distortion and improve steady-state accuracy. I designed the hardware, including the DC-link capacitor, LC filter, gate driver, sampling circuits, zero-crossing detection, protection circuits, and power supplies. I developed the software for the DSP, including the main program, interrupt service routine, phase-locked loop, maximum power point tracking, and current control. Finally, I built a 1 kW prototype and verified the design experimentally.
The simulation results showed that the fuzzy maximum power point tracker responded quickly to irradiance changes and kept the photovoltaic array near its maximum power point. The space vector pulse width modulation produced balanced three-phase voltages and had good DC-link utilization. The hybrid PI and repetitive controller reduced the total harmonic distortion from 7.75% to 3.18% and maintained the active power near 10 kW with nearly zero reactive power. The experimental results confirmed that the grid current was synchronized with the grid voltage and had low distortion. The three-phase solar inverters operated stably and met the basic requirements for grid connection.
For future work, I would like to investigate more advanced maximum power point tracking algorithms, such as neural networks and particle swarm optimization, especially under partial shading conditions. I would also like to study sliding mode control and model predictive control for solar inverters. In addition, I plan to optimize the software, improve the human-machine interface, and add remote monitoring and communication functions. These improvements would make the three-phase solar inverters more intelligent, more efficient, and more suitable for large-scale photovoltaic power plants.