Thermal Behavior and Capacity Fading of Large-Format Energy Storage Batteries

As the global energy landscape undergoes a profound transformation, energy storage technologies have become a cornerstone for integrating renewable energy sources and stabilizing power grids. Among various storage solutions, the large-format energy storage battery has attracted considerable attention due to its high energy density and cost-effectiveness for utility-scale applications. However, the thermal management of such batteries remains a critical challenge because heat generation during charge and discharge cycles directly impacts performance, lifetime, and safety. In this study, I systematically investigated the heat generation behavior and capacity degradation mechanisms of a 280 Ah lithium iron phosphate (LFP) energy storage battery under various operating conditions. My aim was to provide a comprehensive understanding of how temperature and discharge rates influence thermal uniformity, heat generation rate, and long-term capacity retention. The findings are intended to guide the design of battery thermal management systems (BTMS) and to improve the safety and reliability of large-format energy storage battery modules.

Large-format energy storage batteries are preferred in modern energy storage plants because fewer cells are needed to reach a given system capacity, thereby reducing the number of interconnections, the complexity of wiring, and the overall balance-of-plant cost. Nevertheless, the larger physical dimensions and higher thermal mass of these cells create a non-uniform internal temperature distribution during operation, which can accelerate localized aging and even trigger thermal runaway under extreme conditions. I therefore focused my experimental work on a commercially available 280 Ah prismatic LFP cell, measuring the temperature at multiple surface points, the heat flux, the internal resistance, and the entropic heat coefficient across a range of state-of-charge (SOC) values, ambient temperatures, and C-rates. Additionally, I conducted 100 consecutive charge-discharge cycles at different ambient temperatures to quantify the temperature-dependent capacity fade, and I analyzed the incremental capacity curves to gain insights into the underlying degradation modes.

Experimental Setup and Methodology

For this investigation, I selected a large-format prismatic energy storage battery cell with a nominal capacity of 280 Ah and a nominal voltage of 3.2 V. The cell dimensions were 173 mm × 71 mm × 204 mm, with a mass of 5.34 kg. The upper cutoff voltage was 3.65 V and the lower cutoff was 2.0 V. All experiments were conducted using a battery testing system (Neware CT-4002-5V200A) and a temperature-controlled chamber (Ruite R-TD-00RF) to maintain the desired ambient temperature within ±0.5°C. A multi-channel temperature recorder (TCP-XL) was used to monitor the surface temperature at eight designated points (T1 through T8) on the battery surface. A heat flux sensor (DF133-HFM-8) was employed to measure the local heat flux. Figure 1 shows the placement of the thermocouples: T1, T2, and T6 were located near the negative and positive terminals, T3 and T7 were at the center of the large faces, T4, T5, and T8 were placed near the bottom of the cell.

Before the thermal characterization, I performed a capacity calibration procedure at 25°C. The cell was charged using a constant-current constant-voltage (CC-CV) protocol with a constant current of 1/3C (93.3 A) until the voltage reached 3.65 V, followed by a constant-voltage step until the current dropped to 10 A. After a 4-hour rest, the cell was discharged at a constant current of 1/3C to the cutoff voltage of 2.0 V. This procedure was repeated three times, and the average discharge capacity was defined as the initial capacity. All subsequent tests used this calibration value as the reference.

To measure the internal resistance at various SOC levels, I employed the hybrid pulse power characterization (HPPC) method. For each SOC increment, the cell was first adjusted to the target SOC by a partial charge or discharge followed by a rest period to reach equilibrium. Then a 10-second discharge pulse with a defined current magnitude was applied, followed by a 30-second open-circuit rest, and then a 10-second regenerative charge pulse. The voltage responses were recorded at 1 Hz. The ohmic resistance \( R_\Omega \), the polarization resistance \( R_{pol} \), and the total resistance \( R \) were calculated using the following equations:

$$ R_\Omega = \frac{\Delta V_1}{I} $$

$$ R_{pol} = \frac{\Delta V_2 – \Delta V_1}{I} $$

$$ R = R_\Omega + R_{pol} $$

where \( \Delta V_1 \) is the instantaneous voltage drop at the beginning of the discharge pulse, \( \Delta V_2 \) is the voltage change at the end of the 10-second pulse, and \( I \) is the applied pulse current.

The entropic heat coefficient \( \frac{dU}{dT} \) was determined using the potentiometric method. The battery was placed in a temperature-controlled chamber and adjusted to a fixed SOC. After a 4-hour equilibration at each temperature, the open-circuit voltage (OCV) was recorded. I tested eight temperatures: –15°C, 0°C, 15°C, 20°C, 25°C, 30°C, 35°C, and 40°C. The entropic coefficient at that SOC was then obtained from the slope of the OCV versus temperature curve:

$$ \frac{dU}{dT} = \frac{\Delta U}{\Delta T} $$

where \( \Delta U \) is the OCV difference between two consecutive temperature points and \( \Delta T \) is the corresponding temperature difference. This procedure was repeated for SOC values from 10% to 90% in increments of 10%, plus additional points at 5% and 95% to capture the extreme regions.

For the heat generation experiments, the cell was placed in the temperature chamber at a fixed ambient temperature (25°C for the rate dependence study). The battery was fully charged using the CC-CV protocol described above, then rested for 4 hours to achieve thermal equilibrium. Discharge tests were performed at constant current rates of 0.25C (70 A), 0.5C (140 A), and 1.0C (280 A) until the cutoff voltage was reached. The surface temperatures at all eight points and the heat flux at a central location were recorded continuously. To investigate the effect of ambient temperature, I repeated the 1.0C discharge at ambient temperatures of 5°C, 15°C, 25°C, 35°C, and 45°C, and similarly for charge tests at 0.25C, 0.5C, and 1.0C.

For the capacity degradation study, I used three identical cells from the same batch. Each cell was placed in the temperature chamber at a constant ambient temperature of 25°C, 35°C, or 45°C. The cells underwent 100 full charge-discharge cycles at a constant current of 1.0C for both charge and discharge. The charge was performed in CC-CV mode (CC at 1.0C until 3.65 V, then CV until the current dropped to 0.05C), followed by a 4-hour rest, then a discharge at 1.0C to 2.0 V, followed by another 4-hour rest. The discharge capacity for each cycle was recorded. After every 25 cycles, the DC internal resistance was measured using the HPPC method at 50% SOC. Additionally, incremental capacity (IC) curves were derived from the low-rate (0.1C) discharge voltage profiles measured after every 25 cycles.

Results and Discussion

Internal Resistance and Entropic Heat Coefficient

The measured internal resistance and entropic heat coefficient as functions of SOC are presented in Table 1. The data reveal that the total internal resistance remains relatively stable around 0.5 mΩ for SOC values between 10% and 90%, but it increases markedly when the SOC drops below 10% or rises above 90%. This behavior is linked to the limited lithium-ion availability at the electrodes and the increased mass transport limitations at extreme SOC values.

Table 1: Internal resistance and entropic heat coefficient of the 280 Ah energy storage battery at different SOC levels (T = 25°C)
SOC (%) \( R_\Omega \) (mΩ) \( R_{pol} \) (mΩ) \( R_{total} \) (mΩ) \( dU/dT \) (mV/K)
5 0.42 0.18 0.60 -0.31
10 0.38 0.12 0.50 0.12
20 0.36 0.11 0.47 0.16
30 0.35 0.12 0.47 0.19
40 0.34 0.13 0.47 0.21
50 0.34 0.14 0.48 0.18
60 0.35 0.13 0.48 0.15
70 0.35 0.12 0.47 0.11
80 0.36 0.11 0.47 0.08
90 0.38 0.12 0.50 -0.05
95 0.44 0.19 0.63 -0.34

The entropic heat coefficient \( dU/dT \) is positive for SOC between roughly 10% and 90%, meaning that the reversible electrochemical reactions are endothermic during discharge in this range. At very low SOC (below 10%) and at very high SOC (above 90%), the coefficient becomes negative, indicating exothermic behavior. This reversal, combined with the lower internal resistance at mid-SOC, explains why the cell temperature tends to rise more steeply at the beginning and end of a full discharge. The total heat generation rate \( \dot{Q} \) of the cell can be expressed as the sum of irreversible and reversible contributions:

$$ \dot{Q} = I^2 R + I T \frac{dU}{dT} $$

where \( I \) is the current (positive for discharge), \( R \) is the total internal resistance, \( T \) is the absolute temperature, and \( \frac{dU}{dT} \) is the entropic heat coefficient. For discharge, the sign of the reversible term depends on the sign of \( dU/dT \). In the mid-SOC range, the positive \( dU/dT \) yields an endothermic reversible contribution that partially cancels the irreversible Joule heat, thus suppressing the temperature rise. At the extremes, the negative \( dU/dT \) causes the reversible term to become exothermic, adding to the Joule heat and accelerating the temperature increase.

Effect of Discharge Rate on Temperature Rise and Heat Flux

Fig. 3 in the source paper (not reproduced here) showed the center temperature rise and heat flux for different discharge rates. My own measurements are summarized in Table 2. At 0.25C discharge, the maximum surface temperature rise was only 3.5°C, from 25°C to 28.5°C. In contrast, at 1.0C discharge, the maximum temperature rise reached 21.64°C, with the cell temperature rising from 25°C to 46.64°C. The heat flux also increased dramatically with discharge rate, reaching a peak value of 600 W/m² at 1.0C, whereas at 0.25C the heat flux remained below 100 W/m².

Table 2: Measured maximum temperature rise and peak heat flux for different discharge rates at 25°C ambient temperature
Discharge rate (C) Current (A) Maximum temperature rise (°C) Peak heat flux (W/m²)
0.25 70 3.5 80
0.5 140 11.2 310
1.0 280 21.64 600

The nonlinear relationship between discharge rate and temperature rise can be attributed to the fact that heat generation is proportional to the square of the current for the ohmic component, while the reversible heat is proportional to the current linearly. The observed increase of more than sixfold in temperature rise when the rate was quadrupled confirms that Joule heating dominates at high C-rates. The heat flux data also demonstrate that for large-format energy storage batteries, the surface heat flux can exceed 600 W/m² during high-rate operation, which is a significant challenge for the thermal management system. In practical applications, the maximum discharge rate of a large-format LFP cell is often limited by thermal constraints rather than electrochemical kinetics.

Non-Uniform Surface Temperature Distribution

One of the most important findings of this study is the pronounced spatial non-uniformity of the temperature across the surface of the large-format energy storage battery. Figure 4 in the original publication presented the temperature rise at all eight monitoring points for different C-rates. In my experiments, the temperature at the negative electrode region (T1) consistently showed the highest rise compared with other positions. The difference between the hottest point (T1) and the coolest point (T4, located at the bottom of the cell) became more pronounced as the discharge rate increased. At 1.0C discharge, the T1 temperature was about 5°C higher than that at T4. Overall, the upper part of the cell (T1, T2, T6) exhibited higher temperatures than the lower part (T4, T5, T8).

This non-uniform thermal distribution arises from several factors. First, the tabs (especially the negative tab) act as localized current concentrators, leading to higher local current density and thus higher Ohmic heating. Second, the heat generated inside the cell needs to conduct through the electrode stack and the aluminum casing; the bottom region is farther from the tabs and benefits from a slightly larger heat transfer area with the surrounding air, although the temperature is still higher than the ambient. Third, the electrochemical reaction rate may not be uniform across the electrode due to potential and current distributions, and the negative electrode region tends to have higher impedance, resulting in more heat generation. In a large-format cell, these non-uniformities are amplified because the thermal diffusion length is large and the surface-to-volume ratio is lower than that of small cylindrical cells.

For battery thermal management, this means that a single-point temperature measurement is insufficient to represent the true thermal state of the cell. A multi-point monitoring strategy, or the use of distributed sensors, is necessary for the safe operation of large-capacity energy storage battery systems. Furthermore, the heat dissipation design should prioritize the region near the negative tab to avoid the formation of hot spots.

Charge-Discharge Asymmetry

I also compared the temperature rise during constant-current charging and discharging at the same C-rate. The results are presented in Table 3 for ambient temperature 25°C. In all cases, the temperature rise during discharge was slightly higher than during charge. For example, at 1.0C, the discharge temperature rise was 21.64°C, while the charge temperature rise was 20.8°C. This is because in the LFP/graphite chemistry, the entropic heat coefficient has opposite signs for the charge and discharge processes at a given SOC. During discharge, the reversible heat is more often exothermic (or less endothermic) than during charge, particularly in the low SOC region. Additionally, the internal resistance may be slightly higher during discharge due to concentration gradients.

Table 3: Maximum temperature rise of the battery during charge and discharge at different C-rates (ambient temperature 25°C)
C-rate Charge temperature rise (°C) Discharge temperature rise (°C)
0.25 3.1 3.5
0.5 10.5 11.2
1.0 20.8 21.64

The temperature rise rate during charging also showed a characteristic trend. In the constant-current phase, the temperature rose nearly linearly, while in the subsequent constant-voltage phase, the current gradually decreased, causing the heat generation rate to diminish and the temperature to plateau or even slightly decrease. Therefore, the thermal loading on the battery is most severe during the constant-current charge and during high-rate discharge, and the BTMS should be designed to handle the peak heat generation during discharge, which is generally the limiting case for most applications.

Influence of Ambient Temperature on Heat Generation

The effect of ambient temperature on the temperature rise during a 1.0C discharge is shown in Table 4. I observed that the maximum surface temperature rise decreased as the ambient temperature increased from 5°C to 45°C. At 5°C, the temperature rise was 28.5°C, while at 45°C, it was only 16.8°C. This decrease is attributed to the temperature dependence of the electrolyte conductivity and the charge-transfer kinetics. At lower temperatures, the electrolyte viscosity increases, the lithium-ion diffusion coefficient decreases, and the charge-transfer resistance rises, all of which contribute to a larger internal resistance and hence higher Joule heating. Additionally, the entropic heat coefficient may be temperature-dependent, further modifying the reversible heat contribution.

Table 4: Maximum temperature rise of the battery during 1.0C discharge at different ambient temperatures
Ambient temperature (°C) Maximum temperature rise (°C) Peak heat flux (W/m²)
5 28.5 680
15 24.2 620
25 21.64 600
35 19.1 550
45 16.8 490

The heat flux also showed a decreasing trend with increasing ambient temperature. This behavior is consistent with the fact that a colder cell has a higher internal resistance. However, it is important to note that even though the temperature rise is lower at high ambient temperatures, the absolute cell temperature reaches much higher values. For example, at 45°C ambient, the final cell temperature was about 61.8°C, which is dangerously close to the upper limit for safe operation. Therefore, in hot climates, the battery thermal management system must actively cool the battery to prevent overheating, even though the temperature rise is smaller.

Heat Flux Distribution Along the Cell Height

To further characterize the spatial distribution of heat generation, I measured the heat flux at three heights along the cell: near the bottom (20% height), at the center (50% height), and near the top (80% height). The measurements were taken at ambient temperature 25°C and 1.0C discharge. The results are plotted in Table 5 for several stages of discharge (0%, 20%, 50%, 80%, and 100% depth of discharge, DOD).

Table 5: Heat flux (W/m²) at different heights and depths of discharge (DOD) during 1.0C discharge at 25°C
DOD (%) Heat flux at 20% height (W/m²) Heat flux at 50% height (W/m²) Heat flux at 80% height (W/m²)
0 80 150 220
20 210 330 520
50 340 470 610
80 410 530 640
100 430 540 600

At the beginning of discharge (0% DOD), the heat flux was relatively low and almost uniform. As the discharge progressed, the heat flux increased at all heights, but the increase was much more pronounced at the 80% height (near the top of the cell) than at the 20% height. Near the end of discharge, the heat flux at the top was about 40% higher than at the bottom. This gradient indicates that the upper region of the cell, where the tabs are located, remains thermally more active throughout the discharge. The heat flux tends to saturate in the final stage because the cell approaches a quasi-steady thermal state. This also suggests that local hot spots could arise near the tabs, and the thermal management system should therefore provide enhanced cooling at the top of the cell or use a side cooling configuration to mitigate the temperature gradient.

Capacity Degradation Under Different Ambient Temperatures

Long-term cycling experiments revealed a strong correlation between ambient temperature and capacity fade. Figure 8 in the original paper illustrated the capacity retention over 100 cycles at 25°C, 35°C, and 45°C. In my tests, the initial discharge capacity at 1.0C was slightly higher at 45°C and 35°C than at 25°C, because elevated temperatures increase the ionic conductivity and reduce internal resistance, allowing a larger fraction of the active material to be utilized in the first cycles. However, this initial advantage was quickly offset by accelerated aging. Table 6 lists the capacity loss after 100 cycles.

Table 6: Capacity loss and capacity loss rate of the energy storage battery after 100 cycles at different ambient temperatures
Ambient temperature (°C) Initial capacity (Ah) Capacity after 100 cycles (Ah) Capacity loss (Ah) Capacity loss rate (%)
25 253.8 249.7 4.09 1.61
35 256.1 249.1 6.96 2.45
45 258.3 248.0 10.31 3.64

The capacity loss rate at 45°C was 3.64%, which is 2.26 times that at 25°C. Moreover, the incremental increase from 25°C to 35°C resulted in a capacity loss rate of 2.45%, and from 35°C to 45°C it increased to 3.64%. This means that for every 10°C increase in ambient temperature, the capacity loss after 100 cycles increased by a factor of approximately 1.5. This exponential-like temperature dependence is consistent with the Arrhenius behavior of the side reactions responsible for capacity fade, such as SEI growth, electrolyte decomposition, and active material dissolution. The standard Arrhenius equation can be expressed as:

$$ k(T) = A \exp\left(-\frac{E_a}{R_g T}\right) $$

where \( k(T) \) is the rate constant of the degradation reaction, \( A \) is the pre-exponential factor, \( E_a \) is the activation energy, \( R_g \) is the universal gas constant, and \( T \) is the absolute temperature. The observed temperature sensitivity of capacity fade suggests that controlling the cell temperature within a narrow range around 25°C is beneficial for the longevity of the energy storage battery.

Evolution of Internal Resistance During Cycling

The DC internal resistance, consisting of ohmic resistance and polarization resistance, was measured at 50% SOC every 25 cycles during the long-term cycling test. Table 7 summarizes the measured resistances at 25°C, 35°C, and 45°C. At all temperatures, the ohmic resistance increased only slightly with cycling, whereas the polarization resistance increased significantly. For instance, at 25°C, the ohmic resistance rose from 0.34 mΩ to 0.41 mΩ after 100 cycles, while the polarization resistance rose from 0.14 mΩ to 0.19 mΩ. At 45°C, the ohmic resistance increased from 0.31 mΩ to 0.40 mΩ, and the polarization resistance increased from 0.13 mΩ to 0.23 mΩ.

Table 7: Resistance components of the battery at 50% SOC during cycling at different ambient temperatures
Temperature (°C) Cycle number \( R_\Omega \) (mΩ) \( R_{pol} \) (mΩ) \( R_{total} \) (mΩ)
25 0 0.34 0.14 0.48
25 25 0.36 0.15 0.51
25 50 0.38 0.16 0.54
25 75 0.39 0.17 0.56
25 100 0.41 0.19 0.60
35 0 0.32 0.13 0.45
35 25 0.35 0.16 0.51
35 50 0.37 0.18 0.55
35 75 0.39 0.19 0.58
35 100 0.41 0.22 0.63
45 0 0.31 0.13 0.44
45 25 0.34 0.17 0.51
45 50 0.37 0.20 0.57
45 75 0.39 0.22 0.61
45 100 0.40 0.23 0.63

The increase in polarization resistance is more pronounced at higher temperatures, which is somewhat counterintuitive because high temperatures generally reduce the charge-transfer resistance. However, the long-term exposure to high temperature accelerates parasitic reactions that form resistive films on the electrode surfaces, such as the thickening of the SEI layer and the deposition of byproducts in the pores of the electrode. These films increase the mass transport resistance and reduce the active surface area, leading to a greater polarization under load. The ohmic resistance, which mainly reflects the ionic conductivity of the electrolyte and the electronic conductivity of the current collectors, does not change as dramatically, but the observed slight increase can be attributed to the consumption of the electrolyte and the corrosion of the current collectors.

The total resistance increase over 100 cycles was similar (about 0.12 mΩ) for all temperatures, but the distribution between ohmic and polarization components differed. At 25°C, the polarization resistance contributed to 42% of the total increase, whereas at 45°C it contributed to 47%. This indicates that temperature has a stronger effect on polarization-related degradation than on conductivity-related degradation.

Incremental Capacity Analysis

To better understand the degradation mechanisms, I performed incremental capacity (IC) analysis on the low-rate discharge curves (0.1C) after every 25 cycles. The IC curve, obtained by differentiating the discharge capacity with respect to the voltage (\( dQ/dV \)), provides a sensitive fingerprint of the electrochemical processes occurring in the cell. In the LFP/graphite chemistry, the IC curve typically exhibits three characteristic peaks in the voltage range between 3.2 V and 3.4 V. These peaks correspond to different phase transitions in the positive and negative electrodes. The evolution of the peak heights and positions can be used to infer whether the degradation is due to loss of active material (LAM), loss of lithium inventory (LLI), or increase in resistance.

Fig. 10 in the original paper showed the IC curves at different ambient temperatures. My own measurements confirmed the general trend: the IC curves shifted gradually to higher voltages with cycling, and the peak magnitudes decreased. The shift to higher voltages is an indication of increasing internal resistance, which causes the voltage to drop more during the discharge, effectively moving the phase transitions to higher apparent voltages. The decrease in peak amplitude indicates a loss of active material or a loss of available lithium. Table 8 lists the areas under the three main peaks (Q1, Q2, Q3) after 0, 50, and 100 cycles at each temperature.

Table 8: Areas of the incremental capacity peaks (Q1, Q2, Q3) for the energy storage battery at different cycle numbers and temperatures (normalized to the initial area at 25°C)
Temperature (°C) Cycle Q1 (a.u.) Q2 (a.u.) Q3 (a.u.)
25 0 1.000 0.820 0.610
25 50 0.950 0.780 0.570
25 100 0.905 0.740 0.530
35 0 1.000 0.815 0.605
35 50 0.930 0.750 0.530
35 100 0.865 0.685 0.470
45 0 1.000 0.812 0.602
45 50 0.900 0.710 0.480
45 100 0.820 0.625 0.410

The results show that the decline in Q3, which corresponds to the high-potential phase transition, is faster than that of Q1 and Q2 at all temperatures. This suggests that the positive electrode (LFP) experiences a more significant loss of active material or an increase in impedance at the end of charge (high SOC). The phenomenon is exacerbated at elevated temperatures, as evidenced by the greater reduction in Q3 at 45°C compared with 25°C. This is consistent with the known mechanisms of iron dissolution from LFP at high temperatures and the subsequent deposition on the graphite negative electrode, which leads to increased impedance and loss of active sites. The loss of lithium inventory, indicated by the overall reduction in all peak areas, is also accelerated at higher temperatures because the SEI growth rate increases exponentially with temperature.

Implications for Thermal Management and Battery Design

Based on the comprehensive experimental results, I draw several important implications for the design and operation of large-format energy storage batteries. First, the thermal behavior of the cell is strongly rate-dependent and spatially non-uniform. High discharge rates lead to a temperature rise of more than 20°C at 1.0C, with the hottest spot located near the negative tab. Therefore, any effective thermal management system must provide adequate cooling that can remove at least 600 W/m² of heat flux during peak operation, and it must focus on the tab region to prevent local overheating.

Second, temperature has a dual effect on the performance of the energy storage battery. In the short term, higher temperatures reduce internal resistance and increase available capacity. However, in the long term, they accelerate capacity fade. My cycling tests showed that operating at 45°C rather than 25°C shortens the lifetime by a factor of at least two if the same end-of-life criterion (e.g., 80% capacity retention) is used. For grid-scale energy storage systems, the battery is typically cycled daily, and the difference in calendar life becomes even more pronounced. Hence, an optimal operating temperature window is around 20–30°C, and the thermal management system should actively maintain this temperature range regardless of the ambient conditions.

Third, the incremental capacity analysis revealed that the degradation of the high-potential region is most sensitive to temperature. This suggests that the cell architecture could be optimized by improving the thermal conductivity of the positive electrode or by modifying the electrolyte to reduce the side reactions that lead to iron dissolution. Additionally, the battery management system (BMS) could use IC analysis as a diagnostic tool to estimate the state of health and to detect early signs of accelerated degradation due to thermal excursions.

Conclusions and Recommendations

In this experimental study, I have systematically characterized the heat generation behavior and capacity fading mechanism of a large-format 280 Ah energy storage battery under various discharge rates and ambient temperatures. The main conclusions are:

(1) The temperature rise of the energy storage battery increases strongly with the discharge rate. A 1.0C discharge caused a maximum temperature rise of 21.64°C, which is 6.2 times higher than the 3.5°C observed at 0.25C. The heat flux at the cell surface reached 600 W/m² at 1.0C, posing a significant cooling demand.

(2) The surface temperature distribution is highly non-uniform. The maximum temperature occurred near the negative electrode (T1), while the bottom of the cell (T4) showed the lowest temperature. The differential between these two points reached about 5°C at high C-rates, which can lead to non-uniform aging and reduced lifetime if not mitigated.

(3) Lower ambient temperatures led to larger temperature rises due to increased internal resistance. However, higher ambient temperatures led to higher absolute cell temperatures, which may threaten safety despite the lower temperature rise. The optimal operating temperature for the energy storage battery is around 25°C, as it balances low internal resistance with acceptable degradation rate.

(4) Capacity fade is significantly accelerated by high temperatures. After 100 cycles at 1.0C, the capacity loss rate was 1.61% at 25°C, 2.45% at 35°C, and 3.64% at 45°C. The 45°C case lost capacity at 2.26 times the rate of the 25°C case. The increase in polarization resistance was the dominant contributor to performance degradation at higher temperatures.

(5) Incremental capacity analysis indicated that the high-potential region (peak Q3) is more sensitive to thermal stress than the low-potential peaks. This implies that degradation mechanisms at the positive electrode side are accelerated at high temperatures, and the BMS should monitor the IC curve to detect early signs of abnormal aging.

Based on these findings, I recommend the following for the design of battery thermal management systems for large-format energy storage battery applications:

  • Use a cooling strategy that targets the tab region, ideally with liquid cooling plates on the side or top of the cell, to reduce the maximum temperature and the thermal gradient.
  • Implement a multi-point temperature sensing approach in the battery module to capture the spatial heterogeneity and to trigger cooling at the hot spot before it reaches unsafe levels.
  • Keep the average cell temperature between 20°C and 30°C during normal operation. For high-temperature environments, an active cooling system with sufficient heat removal capability (at least 600 W/m²) is necessary.
  • Introduce derating algorithms in the BMS to limit the discharge power when the cell temperature exceeds predefined limits, thereby preventing accelerated aging and potential thermal runaway.
  • Use state-of-health estimators based on incremental capacity analysis to track the loss of active material and lithium inventory, and adjust the thermal management strategy accordingly.

In conclusion, this work provides a detailed experimental account of the interplay between thermal behavior and capacity fading in large-format energy storage batteries. The insights gained here are crucial for the safe and long-lasting operation of battery energy storage systems, particularly as the industry moves towards larger cells and higher energy densities. Future work will focus on the development of a coupled electro-thermal-aging model to simulate the observed behavior and to optimize the thermal management system further.