Experimental Investigation on Enhancing the Charge-Discharge Energy Efficiency of a Liquid-Cooled Energy Storage Cell Pack

In the contemporary landscape of power systems, the rapid integration of intermittent renewable energy sources has created a pressing need for efficient and reliable energy buffering solutions. Among these, electrochemical energy storage cell-based systems, particularly those utilizing lithium iron phosphate (LFP) chemistry, have emerged as a cornerstone technology due to their favorable safety profile, long cycle life, and declining cost. The performance of an energy storage cell pack is critically dependent on its thermal management. Liquid-cooling systems offer superior thermal homogeneity and heat dissipation capability compared to air-cooling, making them essential for high-power, high-energy-density energy storage cell applications. A key metric defining the economic and operational viability of such a system is its round-trip energy efficiency, which directly impacts energy throughput and levelized cost of storage. Recently, updated national standards have placed stricter requirements on the energy efficiency of energy storage cell packs and clusters, underscoring the importance of optimization. This study, conducted from our research perspective, systematically investigates the influence of three critical operational parameters—chiller set-point temperature, initial cell temperature, and voltage operating window—on the charge-discharge energy efficiency of a commercial liquid-cooled LFP energy storage cell pack.

Experimental Methodology and Setup

Our experimental object was a commercially available liquid-cooled energy storage cell pack designed for stationary energy storage applications. The pack configuration and key electrical parameters are summarized in Table 1.

Table 1: Specifications of the Tested Liquid-Cooled Energy Storage Cell Pack
Parameter Specification
Cell Chemistry Lithium Iron Phosphate (LFP)
Number of Cells in Series 52
Nominal Cell Capacity 314 Ah
Cell Voltage Range 2.5 V to 3.65 V
Nominal Cell Voltage 3.2 V
Pack Nominal Voltage 166.4 V (52 × 3.2V)
Standard Charge/Discharge Power (0.5P Rate) 502.4 W
Cooling Method Integrated Liquid Cooling Plate

The test platform comprised a high-precision bi-directional power analyzer for charge-discharge cycling and data acquisition, and a programmable chiller unit to provide precise temperature control for the pack’s liquid cooling loop. All tests were conducted in a temperature-controlled environmental chamber maintained at (25 ± 2)°C. The standard test procedure, adapted from relevant national standards, involved the following sequence: 1) Soak the pack at the target temperature for >8 hours; 2) Charge at constant power (0.5P) to the upper cut-off voltage; 3) Rest for 10 minutes; 4) Discharge at constant power (0.5P) to the lower cut-off voltage. Key parameters recorded included charge energy (Ec), discharge energy (Ed), terminal voltages, and cell voltage differences (ΔV) at the end of charge (EOC) and end of discharge (EOD).

The fundamental metric for evaluation, the round-trip energy efficiency (η), was calculated using the integral form of power over time:

$$
\eta = \frac{E_d}{E_c} \times 100\% = \frac{\int_{0}^{t_d} U_d(t) I_d(t) \, dt}{\int_{0}^{t_c} U_c(t) I_c(t) \, dt} \times 100\%
$$

where \( U_c(t) \) and \( I_c(t) \) are the instantaneous pack voltage and current during charge, \( U_d(t) \) and \( I_d(t) \) are the corresponding values during discharge, and \( t_c \) and \( t_d \) are the total charge and discharge times, respectively. Each test condition was repeated three times, and the average values are reported to ensure statistical reliability.

Impact of Chiller Set-Point Temperature on Energy Storage Cell Pack Performance

The thermal management system’s operating temperature is a primary lever for controlling the energy storage cell‘s electrochemical environment. We investigated this by varying the chiller’s automatic cooling set-point temperature (Tchiller) from 18°C to 26°C while maintaining a standard 0.5P charge-discharge cycle within the full voltage range (2.5V-3.65V per cell). The results for energy efficiency and terminal voltage heterogeneity are plotted in Figure 1 and the detailed data is tabulated in Table 2.

Table 2: Performance of the Energy Storage Cell Pack at Different Chiller Set-Point Temperatures
Chiller Set-Point T (°C) Charge Energy Ec (kWh) Discharge Energy Ed (kWh) Energy Efficiency η (%) EOC ΔV (mV) EOD ΔV (mV)
18 55.72 52.20 93.68 110 138
20 55.62 52.55 94.48 125 162
22 55.83 52.96 94.86 136 153
24 56.03 53.27 95.07 151 207
26 55.95 53.24 95.16 211 293

The data reveals a clear, non-linear relationship. As Tchiller increased from 18°C to 24°C, the energy efficiency improved monotonically from 93.68% to 95.07%, representing a significant gain of 1.39%. This improvement is directly attributable to the reduction in the energy storage cell‘s internal resistance at elevated operating temperatures. The ionic conductivity of the electrolyte and the charge transfer kinetics at the electrodes are thermally activated processes, well-described by an Arrhenius-type relationship. The effective internal resistance (Rint,eff) can be conceptually modeled as a function of temperature:

$$
R_{int,eff}(T) = R_{ohm} + R_{ct}(T) + R_{diff}(T)
$$

where \( R_{ohm} \) is the ohmic resistance (relatively constant), \( R_{ct} \) is the charge-transfer resistance, and \( R_{diff} \) is the mass-transport (diffusion) resistance. Both \( R_{ct} \) and \( R_{diff} \) decrease with increasing temperature, leading to lower overpotential (ηover) during charge and discharge. The energy loss (Wloss) due to this overpotential is proportional to the square of the current (I) and the effective resistance:

$$
W_{loss} \approx I^2 \cdot R_{int,eff}(T) \cdot t
$$

Therefore, a higher operating temperature reduces I2R losses, thereby increasing both Ec and Ed and improving η. However, a critical trade-off emerges. Concurrent with the efficiency gain, the voltage difference (ΔV) between the highest and lowest voltage cells in the pack at the end of charge and discharge increases substantially. At 26°C, the EOC ΔV surges to 211 mV and the EOD ΔV to 293 mV, much higher than the 151 mV and 207 mV observed at 24°C. This accelerated voltage divergence at higher temperatures indicates increased cell-to-cell inconsistency, likely due to variations in internal resistance, state-of-health, or self-discharge rates that are exacerbated by temperature. In a series-connected energy storage cell pack, the charge or discharge process must terminate when any single cell reaches its voltage limit. Severe voltage imbalance causes the pack’s useful capacity to be limited by the weakest cell, leading to premature termination. This effect curtails the discharge energy (Ed), as seen by the plateauing of Ed between 24°C and 26°C despite a slightly higher Ec. Consequently, the marginal gain in efficiency from 24°C to 26°C is only 0.09%, indicating a point of diminishing returns. Based on this analysis, an optimal chiller set-point temperature of approximately 24°C is recommended for this energy storage cell pack, balancing high efficiency with acceptable voltage uniformity.

Influence of Initial Cell Temperature on System Behavior

While the chiller controls the steady-state coolant temperature, the initial temperature of the energy storage cell mass (Tinit) at the beginning of a cycle is another influential parameter, especially for systems undergoing intermittent operation. We adjusted Tinit to 25°C, 29°C, and 33°C by preconditioning the pack with the chiller, then performed the standard 0.5P cycle. The results, shown in Figure 2 and Table 3, present a more complex, non-monotonic trend.

Table 3: Performance of the Energy Storage Cell Pack at Different Initial Average Cell Temperatures
Initial Avg. Cell T (°C) Charge Energy Ec (kWh) Discharge Energy Ed (kWh) Energy Efficiency η (%) EOC ΔV (mV) EOD ΔV (mV)
25 56.40 52.99 93.95 121 138
29 56.07 52.97 94.47 118 153
33 56.43 53.06 94.03 116 118

The energy efficiency peaks at 94.47% when Tinit = 29°C, which is 0.52% higher than at 25°C. However, when Tinit is raised further to 33°C, efficiency drops to 94.03%. This “peak” behavior can be understood by examining the separate trends for Ec and Ed. The charge energy Ec exhibits a “V-shaped” curve: it decreases from 56.40 kWh at 25°C to 56.07 kWh at 29°C, then rebounds to 56.43 kWh at 33°C. In contrast, the discharge energy Ed remains remarkably stable, varying by less than 0.1 kWh across all three temperatures.

This phenomenon is rooted in the dynamic thermal behavior of the energy storage cell pack during operation. During charging, Joule heating and reversible entropic heat generation cause the core temperature of the cells to rise above Tinit. The effective temperature governing the electrochemical processes during most of the charge and the entire discharge is therefore higher than Tinit. A moderately elevated Tinit (29°C) provides a favorable starting point, reducing initial polarization losses. However, an excessively high Tinit (33°C) may lead to accelerated parasitic reactions or slight electrolyte degradation during the charge phase, which could subtly affect coulombic efficiency or increase internal resistance buildup during the test, offsetting the kinetic benefits. This might explain the lower-than-expected Ec at 29°C and the subsequent rebound at 33°C, which could be due to test-to-test variability or a complex interplay of aging effects. Crucially, the discharge process, occurring after the pack has been heated by charging, is less sensitive to the initial condition because the cells are already at an elevated, more uniform temperature. Thus, the primary impact of Tinit is on the charge acceptance characteristics of the energy storage cell pack, while the discharge capability is largely determined by the temperature reached at the end of charge. The optimal initial temperature of around 29°C represents a sweet spot that maximizes overall round-trip efficiency for this specific pack under these test conditions.

Optimization of the Voltage Operating Window for Maximum Efficiency

The characteristic voltage profile of an LFP energy storage cell is marked by a very flat plateau in the mid-state-of-charge (SOC) region and steeper slopes at the extremes (high and low SOC). This shape has profound implications for energy efficiency when managing a series-connected pack. To investigate this, we defined different voltage operating windows relative to the full manufacturer range (2.5V–3.65V). Tests were conducted at the previously identified favorable conditions of Tchiller = 24°C and Tinit ≈ 29°C. The results are depicted in Figure 3 and detailed in Table 4.

A detailed cross-sectional illustration of a prismatic Lithium Iron Phosphate battery cell, showing the layered internal structure including the positive and negative electrodes, separator, and casing.
Table 4: Performance of the Energy Storage Cell Pack Across Different Voltage Operating Windows
Voltage Window (V per cell) Charge Energy Ec (kWh) Discharge Energy Ed (kWh) Energy Efficiency η (%) EOC ΔV (mV) EOD ΔV (mV)
2.50 – 3.65 (Full Range) 56.07 52.97 94.47 118 153
2.50 – 3.55 55.76 52.81 94.71 50 151
2.90 – 3.65 55.61 52.53 94.46 114 51
2.90 – 3.55 (Restricted) 54.47 51.70 94.91 52 53

The findings are highly instructive. Consider the restricted window of 2.90V–3.55V. While the absolute charge and discharge energies are reduced by approximately 2.85% and 2.40% respectively compared to the full range, the energy efficiency increases to 94.91%, the highest value observed in this study. Furthermore, the voltage divergence at both terminals is drastically suppressed, with EOC ΔV at 52 mV and EOD ΔV at 53 mV, representing reductions of about 56-65% from the full-range baselines.

The physics behind this improvement is directly linked to the overpotential characteristics. On the flat voltage plateau, the cell’s effective DC internal resistance is relatively low and stable. The majority of the energy storage cell‘s capacity (often >95%) resides in this region. However, as the cell approaches either voltage extreme, the effective resistance increases sharply due to intensified polarization effects—concentration polarization from depletion/saturation of lithium ions at the electrodes and possible phase changes in the LFP material. The overpotential (ηover) is not constant but is a function of SOC (or voltage):

$$
\eta_{over}(V) = I \cdot R_{int,eff}(V)
$$

where \( R_{int,eff}(V) \) increases significantly near the voltage boundaries. The energy loss during a time interval Δt is:

$$
\Delta W_{loss}(V) = I^2 \cdot R_{int,eff}(V) \cdot \Delta t
$$

Consequently, the segments of the charge and discharge cycles spent at high and low voltages contribute disproportionately to the total energy loss. By truncating the operating window, we eliminate these high-loss regions. Although this sacrifices a small portion of the total usable energy, it dramatically improves the efficiency of the energy that is cycled. This trade-off is quantified by the ratio of efficiency gain to energy loss. For the 2.90V–3.55V window, a 0.44% efficiency gain is achieved at the cost of ~2.4% discharge energy. For many grid applications where cycling efficiency is paramount for economic payback, this can be a favorable optimization. Additionally, the severe reduction in terminal ΔV significantly alleviates balance management burdens and reduces stress on the weakest cells in the energy storage cell pack, potentially enhancing overall pack longevity.

Conclusion and Synthesis

Through a systematic experimental investigation, we have quantified the effects of key operational parameters on the charge-discharge energy efficiency of a liquid-cooled LFP energy storage cell pack. The interplay between temperature management and voltage window strategy is critical for performance optimization.

First, the chiller set-point temperature exhibits a definitive optimal value (~24°C for this pack). Operating at higher temperatures reduces ohmic and polarization losses but exacerbates cell-to-cell voltage inconsistency, leading to premature cycle termination and diminishing efficiency returns. The governing equation balancing loss reduction and voltage divergence can be conceptually framed as maximizing η subject to a constraint on maximum allowable ΔV:

$$
\max_{T} \, \eta(T) = \frac{E_d(T, \Delta V(T))}{E_c(T, \Delta V(T))} \quad \text{s.t.} \quad \Delta V(T) \leq \Delta V_{max}
$$

Second, the initial temperature of the energy storage cell mass presents a local optimum (~29°C), primarily influencing charge acceptance with a complex effect on energy efficiency. This parameter is most relevant for systems with long idle periods.

Third, and most significantly, the choice of voltage operating window is a powerful tool for efficiency engineering. By avoiding the high-polarization regions at the extremes of the SOC range, round-trip efficiency can be markedly improved while simultaneously achieving excellent voltage balance. This strategy directly targets the source of inefficiency. The optimal window can be selected by analyzing the derivative of energy loss with respect to voltage, seeking the point where marginal loss begins to increase precipitously:

$$
\frac{d(W_{loss})}{dV} \quad \text{becomes large near voltage boundaries.}
$$

In practical terms, for a battery management system (BMS) controlling a liquid-cooled energy storage cell pack, the following integrated strategy is suggested: 1) Set the thermal management system to maintain an average pack temperature near the identified optimal chiller set-point (e.g., 24°C). 2) Define charge and discharge cut-off voltages that truncate the full voltage range, effectively using the stable, high-efficiency plateau region (e.g., 2.90V-3.55V per cell). 3) Consider preconditioning the pack to a moderate temperature if coming from a long, cold soak. This multi-variable approach ensures that the energy storage cell pack operates in its most efficient electrochemical and thermal regime, maximizing energy throughput, improving economics, and potentially extending operational life—key objectives for modern, grid-scale energy storage systems.