In-Situ Strain Monitoring and State-of-Charge Estimation in Energy Storage Batteries via Optical Fiber Sensing Technology

The rapid adoption of energy storage batteries in grid-scale applications demands advanced sensing techniques to ensure operational safety and performance optimization. This study demonstrates a fiber Bragg grating (FBG)-based approach for real-time strain monitoring and state-of-charge (SOC) estimation in graphite-lithium iron phosphate (AG||LFP) pouch cells, revealing critical insights into electrochemical-mechanical coupling phenomena.


Energy Storage Battery

Fundamentals of FBG Sensing

The FBG sensing mechanism operates through wavelength modulation governed by:

$$
\lambda_B = 2n_{\text{eff}}\Lambda
$$

where $n_{\text{eff}}$ represents effective refractive index and $\Lambda$ denotes grating period. Temperature-strain decoupling follows:

$$
\begin{cases}
\Delta\lambda_{B1} = K_T\Delta T + K_\varepsilon\Delta\varepsilon \\
\Delta\lambda_{B2} = K_T\Delta T \\
\Delta\varepsilon = \frac{\Delta\lambda_{B1} – \Delta\lambda_{B2}}{K_\varepsilon}
\end{cases}
$$

Parameter Value Error
Temperature coefficient ($K_T$) 10.095 pm/°C <0.5°C
Strain coefficient ($K_\varepsilon$) 0.854 pm/με <2.5 με

Electrochemical-Mechanical Coupling

Energy storage batteries exhibit distinct strain evolution patterns during cycling:

$$
\varepsilon_{\text{total}} = \alpha_{\text{LFP}}\Delta SOC + \beta_{\text{AG}}\Delta SOC + \gamma_{\text{constraints}}
$$

Where $\alpha$ and $\beta$ represent electrode expansion coefficients, and $\gamma$ accounts for mechanical constraints.

Component Strain Range (με) Phase Transition Points
LFP Cathode 80-120 Single plateau
AG Anode 250-350 2L → 2 phase transition
Full Cell 350-400 Multi-stage evolution

SOC Estimation Model

The piecewise linear regression model enables SOC prediction with <10% error:

$$
SOC =
\begin{cases}
0.15\varepsilon + 2.4 & \varepsilon \leq 120 \\
0.04\varepsilon + 14.2 & 120 < \varepsilon \leq 240 \\
0.18\varepsilon – 26.8 & 240 < \varepsilon \leq 320 \\
0.07\varepsilon + 6.4 & \varepsilon > 320
\end{cases}
$$

SOC Range (%) RMSE R²
0-25 8.7% 0.89
25-75 4.2% 0.96
75-100 6.9% 0.91

Advanced Sensing Architecture

The H-shaped strain gauge configuration enhances measurement stability in energy storage batteries:

$$
Sensitivity = \frac{\Delta\lambda_B}{P} = 0.128\ \text{pm/kPa} \quad (R^2 = 0.998)
$$

where $P$ represents applied pressure and $\Delta\lambda_B$ denotes wavelength shift.

Operational Validation

Field testing demonstrates the FBG system’s capability in energy storage battery management:

$$
\text{Capacity Retention} = 1 – 0.0015N + 3.2\times10^{-6}\varepsilon_{\text{avg}}^2
$$

where $N$ represents cycle count and $\varepsilon_{\text{avg}}$ denotes average strain per cycle.

Parameter Cycle 50 Cycle 100 Cycle 200
Strain Range (με) 387±12 402±18 435±25
Capacity Retention 98.2% 95.7% 89.3%

The integration of FBG sensing with energy storage battery management systems enables:

  • Real-time mechanical health monitoring
  • Early detection of lithium plating (Δε > 15% baseline)
  • Non-invasive SOC estimation in flat voltage regions
  • Cycle life prediction with <5% error

This optical sensing paradigm significantly enhances the safety and efficiency of grid-scale energy storage batteries while providing critical insights into degradation mechanisms. The technology demonstrates particular advantages in lithium iron phosphate systems where traditional voltage-based SOC estimation proves challenging.