In this work, we present a comparative study on the deflagration characteristics of hydrogen–air and propane–air mixtures in a box-type explosion vessel designed to mimic the structural features of a typical photovoltaic inverter enclosure. The motivation comes from the urgent need to select an appropriate flammable medium for explosion-resistance qualification tests of solar inverter housings. Thermal runaway events inside solar inverters can generate flammable gases such as hydrogen and propane, which may be ignited by electric sparks or hot surfaces, resulting in cover rupture, projectile debris, and severe safety hazards. Since no dedicated national standard for solar inverter blast resistance currently exists, we followed the recommendation in GB/T 3836.2-2021 for type II electrical apparatus, which permits either hydrogen or propane as the test gas. However, the representative choice between these two gases remained ambiguous. To address this ambiguity, we designed an experimental campaign that directly compares hydrogen and propane deflagrations in a solar inverter-like enclosure and evaluates their subsequent structural damage. We measured pressure–time histories and the residual deformation of thin aluminum cover plates, and we developed predictive relationships between peak overpressure and plate deflection using dimensional analysis and regression. Our results demonstrate that hydrogen deflagration is considerably more severe than propane deflagration in terms of peak overpressure, pressure rise rate, and damage potential, and that the peak overpressure is the dominant parameter controlling plate deflection. The findings provide quantitative guidance for selecting the test gas and for predicting the blast aftereffects in solar inverter qualification procedures.
1. Introduction
The global transition toward renewable energy has accelerated the deployment of photovoltaic systems, and solar inverters are among the most critical components in such systems. A solar inverter converts direct current generated by photovoltaic panels into alternating current suitable for grid connection. Inside a solar inverter, capacitors and electronic components are densely packed, and thermal runaway can occur due to electrical overstress, high ambient temperature, or internal short circuits. During thermal runaway, the electrolyte and polymer materials react and release a mixture of combustible gases, including hydrogen, light hydrocarbons such as propane and methane, carbon monoxide, and other volatile organic compounds. These gases can accumulate inside the sealed housing and form an explosive atmosphere. If the concentration of the flammable gas lies within its explosion limits, a small ignition source such as a spark from a relay or a hot busbar can trigger a deflagration. The resulting internal pressure may exceed the structural strength of the cover plate, causing plastic deformation, rupture, and ejection of fragments. Therefore, the blast resistance of solar inverter enclosures is a critical safety attribute that must be verified under realistic deflagration loads.
The lack of a specific test standard for solar inverter blast resistance means that manufacturers and certification bodies often rely on standards for electrical apparatus in explosive atmospheres. For instance, GB/T 3836.2-2021 specifies that hydrogen or propane can be used as the explosive gas for enclosure explosion tests. However, the deflagration characteristics of hydrogen and propane are quite different. Hydrogen has a much higher burning velocity, lower minimum ignition energy, and wider flammability range than propane. Consequently, a solar inverter enclosure that passes a propane test may not survive a hydrogen test, and vice versa. It is therefore essential to understand the quantitative differences in pressure generation and structural loading between these two gases under the same geometrical conditions representative of solar inverters.
Several previous investigations have explored the explosion behavior of hydrogen and propane in closed or vented vessels. Researchers have reported that the peak explosion pressure of hydrogen–air mixtures often reaches a maximum at a concentration slightly above the stoichiometric value, typically around 30% to 36% by volume, while propane reaches its maximum near 4% to 4.6% by volume. Obstacles, initial pressure, temperature, ignition position, and vessel geometry all influence the pressure rise rate and the peak overpressure. In particular, the presence of internal obstacles can promote flame acceleration through turbulence generation, increasing the severity of the explosion. In solar inverters, components such as capacitors, heat sinks, and busbars create a complex internal geometry that can significantly disturb the flame front. Therefore, we designed a box-type explosion vessel with internal metal tubes to represent the obstructions inside a solar inverter. The vessel geometry and dimensions were selected to resemble a residential solar inverter housing.
The objectives of the present study are:
- to measure the deflagration pressure characteristics of hydrogen–air and propane–air mixtures at different concentrations in a solar inverter-like enclosure;
- to compare the peak overpressure, pressure rise rate, positive pressure impulse, and the resulting deflection of an aluminum cover plate;
- to identify the dominant loading parameter that controls the cover plate deformation by means of regression analysis and the overpressure-impulse criterion;
- to establish empirical relationships between peak overpressure and aluminum plate deflection using dimensional analysis and data fitting.
Our study is expected to support the development of future standards for solar inverter blast resistance and to provide a rational basis for choosing hydrogen or propane as the test medium.
2. Experimental Setup and Methodology
2.1 Test Vessel and Instrumentation
The experimental apparatus consisted of a box-type explosion vessel, a gas mixing and concentration monitoring system, and a high-frequency pressure acquisition system. The vessel was a rectangular steel box with internal dimensions of 496 mm in length, 431 mm in width, and 131 mm in height. The wall thickness was 8 mm and the material was Q355 pressure vessel steel. Inside the vessel, two rows of eight cylindrical metal tubes, each 60 mm long and 30 mm in internal diameter, were welded to the bottom and side walls to represent the internal components of a solar inverter and to create turbulence during flame propagation. The top of the vessel was closed by a removable 1 mm thick AL1070 aluminum alloy cover plate. The cover plate was fastened using ten M10 bolts with an installation torque of 10 N·m. The two short sides of the cover were clamped by the bolts, whereas the two long sides remained free, forming a configuration close to a simply supported beam on the short edges. Silicone sealant was applied at the interface to ensure gas tightness and to prevent leakage before ignition.

The ignition system consisted of a high-energy relay-type spark needle placed at the center of the bottom internal surface. The spark needle was powered by a capacitive discharge unit capable of delivering an ignition energy well above the minimum ignition energy of both hydrogen and propane. A pressure sensor (CY-YD205) was mounted flush with the wall at the center of one side to measure the dynamic pressure. The sensor was connected to a YE5853 charge amplifier and a HDO4000A digital oscilloscope, which recorded the pressure signals at a sampling rate sufficient to capture the rapid pressure transients. The gas mixing system comprised a dynamic gas mixing device (LFIX) connected to high-purity hydrogen and propane cylinders and an air compressor. Two gas concentration analyzers (JFQ-1150E) were used to verify the hydrogen and propane concentrations independently. The hydrogen analyzer had an accuracy of 0.1% by volume, and the propane analyzer had an accuracy of 0.01% by volume.
Table 1 summarizes the key geometric and material parameters of the test vessel.
| Parameter | Value |
|---|---|
| Internal length | 496 mm |
| Internal width | 431 mm |
| Internal height | 131 mm |
| Wall material | Q355 steel |
| Wall thickness | 8 mm |
| Cover plate material | AL1070 aluminum alloy |
| Cover plate thickness | 1 mm |
| Internal tube length | 60 mm |
| Internal tube inner diameter | 30 mm |
| Number of internal tubes | 8 |
| Bolt size / torque | M10 / 10 N·m |
2.2 Gas Mixture Preparation and Test Matrix
We selected six hydrogen concentrations (20%, 25%, 30%, 36%, 45%, and 55% by volume) and seven propane concentrations (3%, 3.5%, 4%, 4.6%, 5%, 5.5%, and 6% by volume). These ranges cover the lean and rich sides of the flammability limits for both fuels. The dynamic gas mixing device generated the desired hydrogen–air or propane–air mixture with a controlled flow rate. The mixture was then continuously injected into the test vessel using a seven-fold volume displacement method to ensure complete replacement of the original air and uniform mixing. After filling, the concentration analyzers were connected to the inlet and outlet ports of the vessel to form a closed-loop monitoring circuit. If the measured concentration deviated from the target value, we adjusted the mixture by injecting additional premixed gas or by diluting with ambient air until the concentration reached the target within the analyzer accuracy. Then the inlets and outlets were sealed, and the vessel was left undisturbed for three minutes to allow the initial turbulence to decay before ignition.
Each concentration condition was repeated three times. We selected the pressure–time trace with the least noise for further analysis. For each test, we replaced the aluminum cover plate with a new one to ensure identical boundary conditions. The maximum deflection along each of the two free long edges was measured using a digital caliper and averaged to obtain the characteristic deflection value for that test.
Table 2 lists the complete test matrix.
| Gas | Concentrations (vol%) | Number of repeated tests per concentration |
|---|---|---|
| Hydrogen | 20, 25, 30, 36, 45, 55 | 3 |
| Propane | 3.0, 3.5, 4.0, 4.6, 5.0, 5.5, 6.0 | 3 |
3. Deflagration Characteristics
We analyzed the raw pressure–time data by reducing the number of data points and applying a smoothing algorithm to remove high-frequency electrical noise. The processed pressure waveforms for hydrogen and propane are discussed below.
3.1 Pressure–Time Histories
Figure 2 in the original publication showed the comparison between raw and processed data; here we summarize the observations. For propane, the pressure–time curves exhibited a single prominent peak. After ignition, a slow pressure rise was observed due to the initial laminar flame propagation. When the flame front encountered the internal tubes and the vessel walls, the resulting flow disturbances and blocking effects increased the turbulence intensity, which wrinkled and stretched the flame front, increased the flame surface area, and accelerated flame propagation. This turbulent acceleration appears as a rapid increase in pressure. When the internal pressure reached a level that caused plastic deformation of the aluminum cover plate, the plate bulged upward, creating a gap through which gas could escape, thus limiting further pressure build-up. When the venting rate balanced the volumetric expansion rate, the pressure reached its peak. After the peak, venting dominated and the pressure declined toward atmospheric pressure.
For hydrogen, the pressure–time histories contained multiple peaks. The multi-peak phenomenon is attributed to shock wave reflection and superposition inside the confined space. Hydrogen deflagration possesses a much higher pressure rise rate than propane and can produce a stronger shock wave in a very short time. Because of the large acoustic impedance mismatch between the gas and the steel walls, the shock wave reflects and superimposes after encountering the internal tubes and enclosure boundaries, generating localized pressure amplification. The pressure sensor recorded these superimposed waves as secondary peaks. For propane, the relatively weak shock waves and their rapid decay make such multi-peak features unresolvable.
In addition, the hydrogen pressure curves displayed Helmholtz oscillations during the venting phase. For example, the 20% hydrogen case exhibited a dominant oscillation frequency of 1600 Hz. This can be explained by the formation of a Helmholtz resonance cavity: the gaseous contents inside the vessel are compressible, and the narrow gap created by the deformed cover plate acts as a neck. After the initial pressure impulse, a pressure difference between the interior and the exterior drives high-temperature gas out through the gap, decreasing the internal pressure. When the internal pressure drops below atmospheric pressure, external air is drawn back into the vessel. This cyclic process leads to periodic pressure fluctuations. Propane, with its lower burning rate and slower pressure decay, did not exhibit such pronounced Helmholtz oscillations.
3.2 Peak Overpressure
Figure 5 from the original publication showed the concentration dependence of peak overpressure for both gases. The propane peak overpressure increased with concentration up to 4% and then decreased. The maximum propane overpressure measured in our tests was 27.5 kPa at 4% propane. The hydrogen peak overpressure reached its maximum of 83.1 kPa at 36% hydrogen. The hydrogen peak overpressure also exhibited a non-monotonic trend, rising to a maximum and then decreasing as the concentration moved toward the rich limit. The optimal peak-pressure concentration for hydrogen was slightly above the stoichiometric concentration (29.6% for hydrogen in air), whereas for propane the optimal concentration was close to its stoichiometric value (4.03%). This observation is consistent with previous studies that the best explosion concentration is generally 1.2–1.4 times the stoichiometric ratio due to incomplete combustion and secondary reactions.
The maximum peak overpressure of hydrogen was approximately three times that of propane: 83.1 kPa versus 27.5 kPa. The underlying reason is that hydrogen has a much faster reaction rate and a higher laminar burning velocity, which leads to more complete combustion during the pressure-rise phase and less energy loss to the vessel walls compared to propane. Consequently, a larger fraction of the chemical energy is converted into pressure.
Table 3 compares the key explosion parameters for the two gases at their respective peak overpressure concentrations.
| Parameter | Hydrogen (36%) | Propane (4%) |
|---|---|---|
| Peak overpressure (kPa) | 83.1 | 27.5 |
| Maximum pressure rise rate (kPa·s-1) | 10387.2 | 1190.4 |
| Time to peak pressure (relative) | Shortest | Shortest |
| Concentration range tested (vol%) | 20–55 | 3–6 |
3.3 Pressure Rise Rate
The pressure rise rate is a measure of the instantaneous rate of pressure build-up and indicates the explosiveness of the mixture. We calculated the maximum slope of the pressure–time curve during the rising phase. For propane, the maximum pressure rise rate was 1190.4 kPa·s-1 at 4% propane. For hydrogen, the maximum was 10387.2 kPa·s-1 at 36% hydrogen, which is 8.7 times higher than that of propane. The higher reactivity of hydrogen, particularly the generation of abundant H· and OH· radicals that propagate chain-branching reactions, and its low ignition energy, result in a much faster flame acceleration inside the obstructed vessel. In the concentration ranges investigated, the pressure rise rate for hydrogen was always greater than that for propane.
The time required to reach peak pressure is another important characteristic. We observed that for both gases, the time to peak pressure decreased as the concentration approached the optimum value and increased as the mixture became leaner or richer. At the optimum concentrations, hydrogen reached its peak pressure much faster than propane due to its higher burning velocity. This shorter pressurization time is directly related to the dynamic loading on the aluminum cover plate.
3.4 Positive Pressure Impulse
Positive pressure impulse is defined as the integral of the overpressure over the positive pressure duration, expressed by:
$$ I = \int_{t_1}^{t_2} \Delta P(t) \, dt $$
where \(I\) is the positive pressure impulse, \(t_1\) and \(t_2\) are the start and end times of the positive pressure phase, and \(\Delta P(t)\) is the time-dependent overpressure. This quantity represents the cumulative effect of the pressure wave on a structure over the positive phase duration.
For propane, the positive pressure impulse reached its maximum at 4% concentration, following the same trend as the peak overpressure. Although the positive duration was shortest at the optimum concentration, the increase in peak overpressure contributed more strongly to the impulse than the reduction in duration. For hydrogen, the impulse also reached a maximum at 36%, but the variation with concentration did not show a simple monotonic or symmetric pattern. In particular, near the stoichiometric concentration, the positive pressure duration for hydrogen was considerably shorter than that for propane, which caused the hydrogen impulse to be smaller than that of propane at equivalent overpressure levels. This distinction is important because the structural response depends not only on the peak load but also on the total momentum transferred to the structure.
4. Blast Aftereffect Analysis
4.1 Damage Potential Comparison
The residual deflection of the aluminum cover plate served as a direct measure of the blast aftereffect. Under the action of the internal pressure, the cover plate deformed plastically outward, forming an arched shape along the long edge centerline. The maximum deflection was measured along each of the two free long edges, and the average value was used as the characteristic deflection for each test. The deflection results are shown in Figure 10 of the original publication and are summarized here qualitatively.
For hydrogen, the maximum deflection occurred at 36% hydrogen, and the deflection increased with concentration up to that point and then decreased. This trend is consistent with the peak overpressure behavior. For propane, the maximum deflection was observed at 4% propane. The magnitude of the deflection caused by hydrogen was globally much larger than that caused by propane over the tested concentration range. This confirms that hydrogen deflagration imposes a more severe structural threat to solar inverter enclosures.
To quantify the relative damage capability, we defined a dimensionless damage index:
$$ \theta = \frac{H_{a}}{H_{b}} $$
where \(H_{a}\) and \(H_{b}\) denote the aluminum plate deflections caused by hydrogen at concentration \(a\) and propane at concentration \(b\), respectively. When \(\theta \approx 1\), the two gases produce similar damage. Inserting our measured deflection values yields:
$$ \theta_{25\%\text{H}_2 / 4.6\%\text{C}_3\text{H}_8}= \frac{H_{25\%\text{H}_2}}{H_{4.6\%\text{C}_3\text{H}_8}} = 1.06 $$
$$ \theta_{36\%\text{H}_2 / 4\%\text{C}_3\text{H}_8}= \frac{H_{36\%\text{H}_2}}{H_{4\%\text{C}_3\text{H}_8}} = 2.82 $$
Thus, 25% hydrogen and 4.6% propane have comparable damage potential, while 36% hydrogen is 2.82 times more damaging than 4% propane. This quantitative comparison helps in selecting the appropriate test gas concentration when simulating the thermal runaway gas environment of a solar inverter.
4.2 Identification of the Dominant Parameter
Peak overpressure and positive pressure impulse are the two primary metrics commonly used to assess explosion effects. We plotted the measured relationships among overpressure, impulse, and deflection for both gases. For propane, both overpressure and impulse increased with deflection, showing strong positive correlations. For hydrogen, overpressure correlated well with deflection, but the impulse did not show a consistent trend: between 20% and 25% hydrogen, both impulse and deflection increased; between 25% and 30%, impulse decreased while deflection increased; between 30% and 36%, impulse increased with deflection; and between 36% and 55%, both decreased. This inconsistency implies that the positive pressure impulse is not the primary controlling variable for hydrogen-induced damage in our configuration.
To determine the dominant parameter statistically, we used linear regression. For propane, since the overpressure and impulse varied in a similar manner with concentration, they were collinear. We therefore performed separate simple linear regressions of the deflection on overpressure and on impulse. The Pearson correlation coefficient \(R\) was computed as:
$$ R = \frac{\sum_{i=1}^{n}(X_i-\bar{X})(H_i-\bar{H})}{\sqrt{\sum_{i=1}^{n}(X_i-\bar{X})^2}\sqrt{\sum_{i=1}^{n}(H_i-\bar{H})^2}} $$
where \(X\) is either peak overpressure or impulse, and \(H\) is the plate deflection. For propane, we obtained \(R_{P-H}=0.999\) and \(R_{I-H}=0.972\), indicating that both parameters are strongly correlated with deflection, but the peak overpressure correlation is slightly stronger.
For hydrogen, because the overpressure and impulse were not strongly coupled, a multiple linear regression model was used:
$$ H = a \Delta P + b I + c $$
where \(a\) and \(b\) are partial regression coefficients and \(c\) is the intercept. The fitting results are listed in Table 4.
| Coefficient | Estimate | Standard error | t-value | p-value |
|---|---|---|---|---|
| a (for \(\Delta P\)) | 0.872 | 0.058 | 14.85 | 6×10-4 |
| b (for \(I\)) | -0.074 | 0.039 | -1.91 | 0.151 |
In the table, the t-value is the ratio of the coefficient estimate to its standard error; a larger absolute t-value indicates a stronger effect of the corresponding independent variable. The p-value is the probability of observing the current t-value under the null hypothesis, with values below 0.05 considered statistically significant. The coefficient for peak overpressure \(a\) is highly significant \(p = 6×10^{-4} < 0.05\), while the coefficient for impulse \(b\) is not significant \(p = 0.151 > 0.05\). This indicates that, after controlling for the effect of overpressure, the impulse does not provide additional explanatory power for the deflection. Therefore, for both gases, peak overpressure is the dominant parameter influencing aluminum plate deformation.
The dominance of overpressure can be further interpreted using the overpressure-impulse (P-I) diagram. The P-I diagram divides the plane into an impulse-controlled region, an overpressure-controlled region, and a combined region. The applicable regime depends on the ratio of the load duration \(T_1\) to the natural period of the structure \(T_2\). When \(T_1 \gg T_2\), the response is quasi-static and overpressure-controlled. When \(T_1 \ll T_2\), the response is impulse-controlled. To assess our situation, we estimated the natural period of the aluminum cover plate. The plate was approximated as a simply supported beam on its two short edges, with the long edges free. Based on Euler–Bernoulli beam theory, the \(n\)-th natural frequency is:
$$ f_n = \frac{n^2 \pi}{2 l^2} \sqrt{\frac{EI}{m}} $$
where \(l\) is the free length of the plate, \(E\) is Young’s modulus, \(I\) is the cross-sectional moment of inertia, and \(m\) is the mass per unit length. The cover plate material properties and dimensions are given in Table 5.
| Parameter | Value |
|---|---|
| Elastic modulus \(E\) | 69 GPa |
| Density \(\rho\) | 2700 kg/m3 |
| Free length \(l\) | 0.496 m |
| Thickness \(d\) | 0.001 m |
The first three natural periods were calculated as \(T_1 = 0.107\) s, \(T_2 = 0.026\) s, and \(T_3 = 0.012\) s. Comparing these periods with the measured positive pressure durations of hydrogen and propane deflagrations, we find that the first-mode natural period and the positive pressure duration are in the same order of magnitude. According to the P-I criterion, the structure would lie in the combined overpressure-impulse region. However, the regression analysis shows that overpressure has a much stronger influence than impulse. One possible explanation is that the high-frequency transient nature of the deflagration and the stress concentration at the bolted supports activate higher-order modes of the plate, whose natural periods are shorter. As the effective natural period decreases, the response moves closer to the overpressure-controlled region. Thus, the peak overpressure becomes the decisive parameter governing the final deflection. This conclusion is important for solar inverter test specification: it implies that the test gas should be selected mainly on the basis of achieving a similar peak overpressure to that expected from a real thermal runaway gas mixture.
4.3 Mathematical Model Between Peak Overpressure and Deflection
To provide a practical engineering tool for predicting the blast aftereffect, we used dimensional analysis to establish a relationship between the peak overpressure \(P\) and the aluminum plate deflection \(H\). For a thin plate under blast loading, the relevant physical parameters are the pressure \(P\), the characteristic length \(l\), the material density \(\rho\), and the elastic modulus \(E\). The function can be expressed as:
$$ H = f(P, l, \rho, E) $$
Using the Buckingham \(\Pi\) theorem with \(\rho\), \(l\), and \(E\) as repeating variables, we obtain the dimensionless groups:
$$ \Pi_1 = \frac{H}{l}, \quad \Pi_2 = \frac{P}{E} $$
Therefore,
$$ \frac{H}{l} = \Phi\left(\frac{P}{E}\right) $$
Since all the aluminum plates in our experiments had the same material and dimensions, \(l\), \(\rho\), and \(E\) are constants. The function can be reduced to a power law:
$$ H = \beta P^{\alpha} $$
where \(\alpha\) and \(\beta\) are empirical constants. We performed nonlinear least-squares fitting for the experimental data of each gas. The resulting empirical equations are shown in Table 6.
| Gas | Empirical equation | Goodness of fit (R2) |
|---|---|---|
| Propane | \(H = 2.1 \, P^{0.66}\) | 0.988 |
| Hydrogen | \(H = 0.2 \, P^{1.28}\) | 0.951 |
In the equations, \(P\) is the peak overpressure in kPa and \(H\) is the deflection in mm. Both equations exhibit good fitting accuracy, with R2 values above 0.95. The difference in the exponents reflects the different loading characteristics of the two gases. For propane, the exponent is less than unity, indicating a somewhat saturating effect of pressure on deflection. For hydrogen, the exponent is greater than unity, meaning that deflection increases more rapidly with pressure, which is consistent with the more impulsive and intense pressure loading produced by hydrogen. These models allow engineers to estimate the cover plate deflection of a solar inverter enclosure when the peak internal deflagration pressure is known from pressure calculations or CFD simulations.
5. Discussion
The results of this study have significant implications for the design and certification of solar inverter enclosures. The selection of hydrogen or propane as the test gas in an explosion-resistance test should not be made arbitrarily. If a solar inverter is likely to be exposed to hydrogen-rich thermal runaway gases, then testing with hydrogen is necessary because propane tests would underestimate the potential damage. Conversely, if the thermal runaway gas mixture is dominated by heavier hydrocarbons with overpressure characteristics close to propane, then a propane test may be sufficient. Our data suggest that 25% hydrogen and 4.6% propane produce similar damage in the tested enclosure geometry. Therefore, for a standard test, one could either use 25% hydrogen as a representative hydrogen-based condition or 4.6% propane as a propane-based condition, depending on which gas is more relevant to the actual application. However, since the peak overpressure is the dominant parameter, a more rational criterion for gas selection is to compare the peak overpressure of the candidate test gas with the expected peak overpressure from the actual gas mixture under the same geometrical and initial conditions.
The empirical equations derived here provide a simple relationship between peak overpressure and plate deflection. They can be used in preliminary design calculations for solar inverter housings. For instance, if the maximum allowable deflection of the cover plate is specified, the corresponding maximum allowable overpressure can be estimated, and the explosion venting or structural reinforcement requirements can be determined accordingly. It must be noted that the equations are based on a specific plate thickness, material, and boundary condition. Extrapolation to other geometries should be conducted with caution. Additional experiments covering different plate thicknesses, sizes, and boundary conditions would be needed to generalize the model.
Another important observation is the occurrence of Helmholtz oscillations during the venting phase of hydrogen deflagration. These oscillations can induce alternating positive and negative pressures that may cause fatigue damage to the cover plate and its fasteners, especially if the oscillation frequency is close to a structural natural frequency. In solar inverter enclosures, the presence of gaskets and thin panels may introduce complex fluid-structure interactions. The measured oscillation frequency of 1600 Hz for the 20% hydrogen case is far from the first-mode natural frequency of the plate (about 9.3 Hz if f1≈1/T1=9.35 Hz? Wait: Actually T1=0.107s, f1≈9.35 Hz). The oscillation frequency is much higher than the fundamental plate frequency, but could approach higher-order mode frequencies. Further study is needed to assess the fatigue and noise implications.
In addition, the internal geometry of the solar inverter plays a critical role in the deflagration severity. Our vessel included eight metal tubes to represent components, but real solar inverters have a much more complex arrangement of PCBs, capacitors, inductors, and heat sinks. The turbulence generated by these obstacles can significantly alter the pressure rise rate and peak pressure. Therefore, the present results should be interpreted as a relative comparison between hydrogen and propane under the same idealized geometry, rather than an absolute prediction for every production solar inverter. Nevertheless, the qualitative conclusion that hydrogen produces higher overpressure and more severe damage than propane is expected to hold across different geometries.
We also note that the concentration range tested in this study covers the most hazardous regions for both fuels. The maximum overpressure occurred at 36% for hydrogen and 4% for propane, which are close to previously reported optimum concentrations. The fact that the peak overpressure of hydrogen at 36% is about three times that of propane at 4% underscores the importance of considering the gas composition in the thermal runaway scenario. If a solar inverter is subjected to an internal fault that generates hydrogen, the enclosure must be designed to withstand pressures at least three times higher than what a propane-based certification test would impose.
6. Conclusion
In this paper, we experimentally compared the deflagration characteristics of hydrogen–air and propane–air mixtures in a box-type explosion vessel that mimics a solar inverter enclosure. The following conclusions are drawn:
- Hydrogen deflagration produced significantly higher peak overpressure, higher pressure rise rate, and greater aluminum plate deflection than propane over the tested concentration ranges. The maximum peak overpressure was 83.1 kPa for 36% hydrogen, while propane reached only 27.5 kPa at 4%. The maximum pressure rise rate for hydrogen was 10387.2 kPa·s-1, which is 8.7 times higher than that of propane.
- The damage potential of hydrogen and propane can be compared through the damage index \(\theta\). In the present enclosure, 25% hydrogen and 4.6% propane produced nearly equivalent damage (\(\theta = 1.06\)), whereas 36% hydrogen was 2.82 times more damaging than 4% propane.
- Regression analysis and the overpressure-impulse criterion jointly indicate that the peak overpressure is the dominant parameter controlling the deformation of the aluminum cover plate. For hydrogen, the multiple linear regression showed a highly significant coefficient for overpressure (\(p = 6×10^{-4}\)) and a non-significant coefficient for impulse (\(p = 0.151\)). Therefore, selecting a test gas that yields a peak overpressure similar to that of the actual thermal runaway gas is the most reasonable approach for solar inverter blast resistance tests.
- Dimensional analysis and nonlinear fitting provided empirical power-law relationships between peak overpressure and plate deflection: \(H = 2.1 P^{0.66}\) for propane and \(H = 0.2 P^{1.28}\) for hydrogen, with R2 values of 0.988 and 0.951, respectively. These equations can be used to rapidly estimate the blast aftereffect of hydrogen and propane deflagrations on solar inverter enclosures.
The findings of this study offer a quantitative basis for the future development of solar inverter explosion-resistance test standards and assist manufacturers in choosing conservative test gases and structural design margins. Future work will involve testing with gas mixtures representing actual thermal runaway products, exploring the influence of venting area, and validating the scale-up of the empirical models to full-size solar inverter enclosures.