Solar inverters are now one of the most important power-electronics components in modern renewable-energy systems. Their function is to convert the variable direct-current output from photovoltaic arrays into a stable alternating-current waveform that can be fed into the public grid or used in local loads. In recent years, solar inverters have been widely deployed in residential, commercial, and utility-scale photovoltaic plants. Along with their growing popularity, however, a serious safety concern has emerged: when an internal capacitor fails owing to high voltage stress, thermal runaway, or manufacturing defects, it can release flammable gases and electrolyte vapour. If a subsequent short circuit creates a spark inside the enclosed cabinet, the flammable mixture can be ignited. The resulting explosion may damage the enclosure, eject the front cover, and endanger nearby personnel. Therefore, understanding the explosion behaviour inside solar inverters and improving their blast resistance is a crucial engineering task.
In my study, I focused on a commercial photovoltaic inverter chassis as the research object. I first investigated the factors that control the explosion overpressure inside the enclosure, including fuel concentration, obstacle distribution, ignition energy, and ignition position. I then carried out both experiments and numerical simulations to observe the dynamic response of the solar inverter enclosure under the most severe internal blast loads. Finally, I proposed an energy-absorbing connection scheme based on induced-hole thin-walled circular tubes. The results show that this simple and low-cost modification can significantly improve the blast safety of solar inverters.

1. Explosion mechanisms of combustible gases
An explosion in a confined space is caused by the rapid oxidation of a flammable gas or vapour. The released heat produces high-temperature combustion products, and the sudden volume expansion generates pressure waves. In this project, I used propane as the test gas because it is a common substitute for the complex fuel mixtures released by failed capacitors. The overall stoichiometric reaction for propane combustion is:
$$ \mathrm{C_3H_8 + 5O_2 \rightarrow 3CO_2 + 4H_2O} $$
If the initial pressure and temperature are constant and the volume is fixed, the ideal-gas explosion pressure can be estimated from the adiabatic flame temperature:
$$ P_{\max} = P_0 \frac{T_{\max}}{T_0} \frac{n_{\max}}{n_0} $$
where \(P_0\) and \(T_0\) are the initial pressure and temperature, \(T_{\max}\) is the maximum combustion temperature, and \(n\) is the number of moles. In reality, the maximum pressure is also influenced by heat losses, incomplete combustion, and flame instabilities. Therefore, the stoichiometric concentration is only a first approximation. Experiments are needed to find the concentration that produces the highest peak overpressure in a particular enclosure.
The combustion reaction can be described by thermal explosion theory and chain-reaction theory. In the chain-reaction mechanism, active radicals such as H, O, and OH are generated after ignition. These radicals react with fresh fuel molecules and create new radicals, leading to an exponential acceleration of the reaction rate. If the heat generation rate exceeds the heat loss rate, the temperature rises rapidly and a flame front propagates through the unburned mixture. In a long channel or cluttered enclosure, the flame can accelerate and undergo a deflagration-to-detonation transition. Under detonation conditions, the pressure and velocity can be orders of magnitude higher than in simple deflagrations. This phenomenon is particularly important for solar inverters because the internal electronic boards act as obstacles that accelerate the flame.
2. Energy-absorption evaluation metrics
To evaluate the energy-absorption performance of protective structures, I adopted several standard metrics. The instantaneous crushing force \(F(s)\) is measured as a function of axial displacement \(s\). The maximum crushing force \(F_{\max}\), also called peak crushing force, is the largest reaction force that appears during the energy-absorption process. The effective compression stroke \(S_{ef}\) is the displacement range from initial loading to the beginning of structural densification. The average crushing force \(F_c\) is defined as:
$$ F_c = \frac{1}{\delta} \int_0^{\delta} F(s) \, ds $$
where \(\delta\) is the total compressed distance. The specific energy absorption \(SEA\) is defined as the absorbed energy per unit mass:
$$ SEA = \frac{1}{m} \int_0^{\delta} F(s) \, ds $$
where \(m\) is the mass of the deformed component. A higher \(SEA\) indicates that the material is used more efficiently. In my optimisation study, I used \(F_{\max}\), \(F_c\), and \(SEA\) as the primary criteria for evaluating the blast-mitigation connection elements of solar inverters.
| Metric | Symbol | Definition | Purpose |
|---|---|---|---|
| Peak crushing force | \(F_{\max}\) | Maximum reaction force during compression | Indicates the initial impact severity |
| Effective stroke | \(S_{ef}\) | Displacement before densification | Measures available deformation length |
| Average crushing force | \(F_c\) | \(\frac{1}{\delta}\int_0^\delta F(s) ds\) | Represents mean resistance |
| Specific energy absorption | \(SEA\) | \(\frac{1}{m}\int_0^\delta F(s) ds\) | Measures mass efficiency |
3. Experimental system design
I designed a dedicated experimental platform to test the blast resistance of solar inverters. The platform consisted of a real photovoltaic inverter cabinet, a dynamic gas-mixing system, a controllable ignition-energy unit, a high-speed imaging system, and a pressure-acquisition system. The enclosure had a size of approximately 192 cm by 139 cm by 102 cm. The internal cavity was filled with a precisely mixed propane–air mixture. The gas concentration was produced by mass-flow controllers and verified by an online concentration analyser.
For ignition, I used a spark-discharge system with adjustable energy levels of 1 J, 2 J, 3 J, 4 J, and 5 J. The spark was triggered by a capacitor discharge circuit, and the discharge voltage and current were recorded to estimate the delivered spark energy. Pressure was measured with piezoelectric sensors mounted on the cover plate. The sensor signal was converted into pressure using:
$$ \Delta P = \frac{V_{set} S_{set}}{K_v S_q} $$
where \(V_{set}\) is the set voltage of the charge amplifier, \(S_{set}\) is the sensor sensitivity setting, \(K_v\) is the amplifier gain, and \(S_q\) is the charge sensitivity of the pressure sensor. The high-speed camera was operated at 3000 frames per second to record the deformation of the cover and connections during the explosion.
| Subsystem | Components | Function |
|---|---|---|
| Gas-mixing system | Mass-flow controllers, mixer, concentration analyser | Prepares uniform propane-air mixtures |
| Ignition system | High-voltage source, capacitor bank, electrodes | Provides controlled spark energy |
| Pressure acquisition | Piezoelectric sensors, charge amplifier, oscilloscope | Records transient blast pressure |
| High-speed imaging | High-speed camera, computer | Captures cover motion and failure modes |
A gas replacement procedure was used to set the oxygen concentration inside the solar inverter enclosure. Air and propane were first mixed in a pre-chamber and then supplied into the cabinet while the original air was displaced through a vent. After the concentration analyser stabilised at the desired value, all valves were closed. The enclosure was then kept sealed for three minutes to verify that there was no leakage. After the test, the damaged cover, bolts, and other connectors were examined and the flying distance of the cover was recorded when separation occurred.
4. Effects of initial conditions on explosion overpressure
4.1 Propane concentration
Initial experiments were carried out in a small sealed explosion vessel to determine the optimum propane concentration. I tested concentrations from 4.0% to 4.9% by volume in steps of 0.1%. The ignition energy was fixed at 1 J, and the ignition point was located at the bottom of the vessel. Table 1 lists the measured peak pressures, arrival times, and average pressure-rise rates.
| Propane concentration | Peak pressure / bar | Time to peak / ms | Average rise rate / bar·ms⁻¹ |
|---|---|---|---|
| 4.0% | 3.20 | 5.95 | 0.537 |
| 4.1% | 3.18 | 5.93 | 0.536 |
| 4.2% | 3.26 | 5.97 | 0.546 |
| 4.3% | 3.29 | 6.01 | 0.547 |
| 4.4% | 3.32 | 6.05 | 0.549 |
| 4.5% | 3.33 | 6.04 | 0.551 |
| 4.6% | 3.36 | 6.06 | 0.554 |
| 4.7% | 3.35 | 6.11 | 0.548 |
| 4.8% | 3.31 | 6.06 | 0.546 |
| 4.9% | 3.25 | 5.99 | 0.542 |
The results show that the optimum concentration is about 4.6% propane, which is not exactly the stoichiometric concentration. The stoichiometric volume fraction for propane in air is 4.02%. Because of incomplete combustion, dissociation of combustion products, and secondary reactions, the maximum overpressure occurs at a slightly fuel-rich condition. The ratio is:
$$ \eta = \frac{(fuel/air)_{actual}}{(fuel/air)_{stoich}} \approx 1.15 $$
When the concentration exceeds 4.6%, the oxygen supply becomes insufficient, and the excess propane acts as a diluent that reduces the reaction rate and peak pressure.
4.2 Obstacle spacing
In real solar inverters, the electronic circuit boards and power modules act as obstacles inside the enclosure. To study this effect, I used the computational-fluid-dynamics software Fluent with a premixed combustion model. Four obstacle plates, each 200 mm long and 10 mm thick, were placed in a rectangular channel. The obstacle spacing was varied as 100 mm, 200 mm, and 300 mm. The Zimont turbulent-flame-speed model was used:
$$ U_t = A (u’)^{3/4} U_l^{1/2} \alpha^{-1/4} \delta_t^{-1/4} $$
where \(A\) is a model constant, \(u’\) is the RMS turbulent velocity, \(U_l\) is the laminar flame speed, \(\alpha\) is the thermal diffusivity, and \(\delta_t\) is the turbulent flame thickness. The propane mixed fraction was calculated as:
$$ f = \frac{\eta}{\eta + r} $$
with the stoichiometric mass ratio \(r\). For the 4.6% propane-air mixture, I obtained \(f = 0.06852\). Three monitoring points were defined at different positions along the channel.
The simulation results are summarised in Table 2. The presence of obstacles increased the peak pressure significantly compared with the empty channel. The peak pressure rose with obstacle spacing, but the rate of increase diminished. At a spacing of 300 mm, the peak pressure at the first monitoring point reached 0.628 MPa, while the empty channel produced only 0.121 MPa.
| Obstacle spacing | Monitoring point | Peak pressure / MPa | Peak velocity / m·s⁻¹ | Peak temperature / K |
|---|---|---|---|---|
| No obstacle | P1 | 0.121 | 206 | 2278 |
| No obstacle | P2 | 0.119 | 208 | 2237 |
| No obstacle | P3 | 0.110 | 355 | 2039 |
| 100 mm | P1 | 0.397 | 268 | 2411 |
| 100 mm | P2 | 0.398 | 451 | 2237 |
| 100 mm | P3 | 0.357 | 489 | 1950 |
| 200 mm | P1 | 0.551 | 368 | 2435 |
| 200 mm | P2 | 0.591 | 536 | 2281 |
| 200 mm | P3 | 0.518 | 575 | 1883 |
| 300 mm | P1 | 0.628 | 435 | 2440 |
| 300 mm | P2 | 0.626 | 383 | 2348 |
| 300 mm | P3 | 0.537 | 557 | 1892 |
For the flame speed, the obstacle spacing that produced the highest exit velocity was 200 mm, not 300 mm. This suggests that there is an optimum spacing for flame acceleration. At very small spacing, the obstacles hinder rather than assist the flame propagation because the recirculation zones merge and dissipate turbulent kinetic energy. At very large spacing, the flame has time to decelerate before reaching the next obstacle. Therefore, in the design of solar inverters, the arrangement of internal components can influence the maximum possible explosion load.
4.3 Obstacle blockage ratio
I then varied the blockage ratio from 30% to 70% by changing the obstacle length while keeping the spacing fixed at 300 mm. Table 3 presents the key explosion parameters at the three monitoring points. The 50% blockage ratio produced the highest peak pressure and the highest flame speed at the exit. If the blockage ratio was too small, the obstacle did not generate sufficient turbulence; if it was too large, the flame lost too much energy while passing through the narrow gaps and could even be extinguished.
| Blockage ratio | Monitoring point | Peak pressure / MPa | Peak velocity / m·s⁻¹ | Peak temperature / K |
|---|---|---|---|---|
| 30% | P1 | 0.454 | 109 | 2396 |
| 30% | P2 | 0.461 | 467 | 2241 |
| 30% | P3 | 0.424 | 504 | 1935 |
| 40% | P1 | 0.522 | 242 | 2424 |
| 40% | P2 | 0.551 | 515 | 2242 |
| 40% | P3 | 0.492 | 560 | 1947 |
| 50% | P1 | 0.550 | 369 | 2435 |
| 50% | P2 | 0.590 | 536 | 2281 |
| 50% | P3 | 0.517 | 575 | 1983 |
| 60% | P1 | 0.537 | 411 | 2443 |
| 60% | P2 | 0.589 | 549 | 2357 |
| 60% | P3 | 0.493 | 567 | 1940 |
| 70% | P1 | 0.532 | 369 | 2447 |
| 70% | P2 | 0.519 | 525 | 2437 |
| 70% | P3 | 0.419 | 534 | 1907 |
4.4 Ignition position
In a real solar inverter, the location of the failed capacitor determines where the flammable mixture is ignited. I tested four ignition positions in the enclosure: top-centre, top-side, bottom-centre, and bottom-side. The experimental results are shown in Table 4. The bottom-centre ignition produced the highest peak pressure. A bottom ignition gives the flame a longer distance to travel before reaching the cover, providing more space for the deflagration-to-detonation transition. Within the same horizontal plane, the centre ignition always produced a higher peak pressure than the side ignition because the flame can develop spherically without early interaction with the side walls.
| Ignition position | Peak pressure / bar | Time to peak / s |
|---|---|---|
| Top-centre | 1.66 | 0.018 |
| Top-side | 1.62 | 0.016 |
| Bottom-centre | 2.36 | 0.020 |
| Bottom-side | 2.05 | 0.023 |
I also carried out comparison experiments in an empty cabinet without obstacles. In that case, the central ignition produced the highest pressure, while the side and bottom ignitions produced lower values because the flame entered the hemispherical regime earlier and lost heat to the nearby wall. This confirms that obstacles are the dominant factor controlling blast severity in solar inverters.
4.5 Ignition energy
The ignition energy was varied from 1 J to 5 J at the centre position. As shown in Table 5, both the peak pressure and the pressure-rise rate increased with ignition energy. A larger spark creates a larger initial flame kernel, leading to faster combustion and stronger pressure waves. This result indicates that any anti-explosion system in solar inverters must consider the maximum energy that could be delivered by an internal electrical fault.
| Ignition energy | Peak pressure / bar | Pressure rise rate / bar·s⁻¹ |
|---|---|---|
| 1 J | 1.66 | 1216 |
| 3 J | 2.05 | 1877 |
| 5 J | 2.36 | 2098 |
4.6 Ambient temperature
I also investigated the effect of initial ambient temperature. A sealed enclosure with an initial temperature of 350 K produced a lower peak pressure than one at 300 K. Although the flame speed was higher at elevated temperature, the gas density and therefore the amount of fuel in the fixed volume were lower. The net effect was a reduction in peak pressure. This is important for solar inverters because the internal temperature of a cabinet may be elevated during normal operation or thermal runaway.
5. Dynamic response of the solar inverter enclosure under blast
After determining the most severe ignition conditions, I carried out explosion tests on a complete solar inverter enclosure. The ignition point was placed at the bottom-centre, the propane concentration was 4.6%, and the ignition energy was 5 J. In the first set of tests, the cover was not bolted so that the initial velocity of the cover could be measured. The pressure–time curve was integrated to obtain the impulse:
$$ I = \int_0^t P(t) \, dt $$
The measured peak pressure was 0.136 MPa, and the impulse was 3.35 kg·m/s. Using the mass of the cover \(M = 0.46\) kg, the theoretical initial velocity is:
$$ V = \frac{I}{M} = \frac{3.35}{0.46} = 7.28 \ \text{m/s} $$
The high-speed camera measured an initial cover velocity of 7.08 m/s, which is close to the theoretical value. This value was then used as the initial velocity in the numerical simulation.
A finite-element model of the photovoltaic inverter was built using the explicit dynamics code LS-DYNA. The model included the cover, the housing, the bolts, the gaskets, the fixed columns, and the connecting supports. The material behaviour was described by the piecewise-linear plasticity model with strain-rate dependence:
$$ \sigma_y = \left( \sigma_0 + \beta E_p \varepsilon_{eff}^p \right) \left( 1 + \frac{\dot{\varepsilon}}{C} \right)^{1/p} $$
The material constants used in the model are listed in Table 6. The failure strain was set separately for each component so that the simulations could reproduce the observed fracture and separation behaviour.
| Component | Density / g·cm⁻³ | Young’s modulus / Mbar | Poisson’s ratio | Yield stress / Mbar | Tangent modulus / Mbar |
|---|---|---|---|---|---|
| Cover | 2.70 | 0.665 | 0.33 | 0.00142 | 0.01105 |
| Fixed column | 2.70 | 0.665 | 0.33 | 0.00142 | 0.01105 |
| Bolt | 7.75 | 1.931 | 0.305 | 0.00339 | 0.00165 |
| Gasket | 2.69 | 0.724 | 0.33 | 0.00287 | 0.00543 |
| Housing | 7.83 | 2.050 | 0.30 | 0.00350 | 0.00636 |
The numerical results showed that the cover is violently lifted by the explosion, and the bolted connections at the edges fail in tension. The cover bulges outward by about 10.6 mm, while the experimental value was 11.3 mm. The good agreement validates the simulation approach.
I divided the dynamic response into three stages. In the first stage, the blast load interacts with the cover and the connecting members, producing a very short but intense stress concentration. In the second stage, the load-carrying members undergo plastic deformation and absorb energy. In the third stage, the members reach their ultimate strain and fracture. The cover separates from the housing and flies away, creating a severe safety hazard. The Mises stress analysis indicated that the highest stresses initially appear in the bolts and in the central region of the cover. Stress waves then propagate outward from the connection points in a wavy pattern. During the later phase, stress is concentrated at the tensile fracture locations, eventually leading to complete failure.
Table 7 presents the energy distribution among the components in the original solar inverter enclosure. The cover absorbed 78.8% of the total energy through plastic deformation, and the bolts absorbed 6.5%. This means that the cover and bolts were the primary energy-dissipating elements. Their large plastic deformation caused fracture and ejection, which is unacceptable for a product designed to protect life and property.
| Component | Final absorbed energy / J | Energy percentage |
|---|---|---|
| Cover | 155.2 | 78.8% |
| Bolts | 9.94 | 6.5% |
| Cover supports | 16.1 | 10.3% |
| Gaskets | 0.1 | 0.065% |
| Housing | 6.56 | 4.3% |
6. Optimisation with induced-hole thin-walled tubes
To improve the blast resistance of solar inverters, I introduced an energy-absorbing thin-walled circular tube with induced holes. The tube is placed between the cover and the fixed support, so that when the cover is pushed outward by the internal blast, the tube is crushed axially and absorbs a large portion of the kinetic energy. This type of device is inexpensive, easy to retrofit, and does not require any changes to the existing enclosure geometry.
The tube material was aluminium alloy 6061-T6, with a nominal outer radius of 6 mm, length of 30 mm, and wall thickness \(t\). The holes were arranged in either an aligned or a staggered pattern. I used the SHPB test to measure the high-strain-rate properties of the alloy. The measured static and dynamic parameters are listed in Table 8. The Cowper-Symonds strain-rate hardening parameters were calibrated from the SHPB data.
| Property | Value |
|---|---|
| Density | 2686 kg/m³ |
| Young’s modulus | 72.4 GPa |
| Specific heat | 937.4 J·kg⁻¹·K⁻¹ |
| Poisson’s ratio | 0.32 |
| Initial yield stress | 286.8 MPa |
| Tangent modulus | 542.6 MPa |
Finite-element simulations were performed for a single tube impacted by a moving plate with an axial velocity equal to the measured cover velocity. The mesh consisted of 2 mm quadrilateral shell elements. The numerical model reproduced the experimentally observed deformation patterns with an error of about 4% in the final crushed length, which confirmed that the model was suitable for parametric studies.
6.1 Deformation modes
I identified four typical deformation modes for the induced-hole tubes:
- Axisymmetric progressive folding, where folds develop sequentially from the impact end toward the fixed end.
- Global simultaneous deformation, where all rows of holes deform at the same time without producing a stable fold.
- Euler buckling, where the tube bends globally and loses its axial stability.
- Incomplete deformation, where the middle row of holes acts as a weak point causing shear fracture.
The axisymmetric mode is the most desirable because it provides a stable and long plateau force, resulting in high energy absorption. The other modes reduce the useful stroke and may cause early structural failure.
6.2 Influence of hole-row number
I first studied tubes with zero to four rows of holes. Table 9 shows that increasing the number of holes reduces the peak crushing force. Compared with the no-hole tube, the one-row tube had a 24% lower \(F_{\max}\). The specific energy absorption increased initially but decreased when the hole-row number was increased to four because the excessive weakening reduced the total energy absorption.
| Number of hole rows | \(F_{\max}\) / kN | \(SEA\) / J·g⁻¹ | \(F_c\) / kN |
|---|---|---|---|
| 0 | 14.10 | 36.73 | 6.25 |
| 1 | 10.70 | 39.36 | 5.89 |
| 2 | 8.67 | 43.08 | 5.39 |
| 3 | 8.26 | 44.64 | 5.21 |
| 4 | 8.18 | 44.38 | 4.92 |
6.3 Influence of wall thickness and hole radius
I created 30 combinations of wall thickness \(t\) from 0.5 mm to 3.0 mm and hole radius \(r\) from 0.5 mm to 2.5 mm. The results show that wall thickness has a strong effect on the load-carrying capacity. For very thin tubes with \(t = 0.5\) mm, Euler buckling occurs regardless of the hole size. For thicker tubes, a suitable hole radius can generate stable axisymmetric folding. However, when \(t = 3\) mm, the middle row of holes produces local weakening and shear failure before the impact end can deform.
An important finding is that the hole radius determines the degree of structural weakening. If the hole is too small, it does not create an effective collapse initiator. If the hole is too large, the force drops excessively and the energy absorption decreases. The optimum combination in this series was \(t = 1\) mm and \(r = 1.5\) mm, which achieved a high specific energy absorption while maintaining a relatively low peak crushing force.
6.4 Influence of impact velocity
I also varied the initial impact velocity between 6 m/s and 8 m/s. At velocities below a critical value, the tube tended to buckle in the Euler mode. Above the critical velocity, a stable axisymmetric folding mode was observed. The peak force was independent of the impact velocity, but the average crushing force and the specific energy absorption increased with increasing velocity. This is because dynamic effects and inertia tend to stabilise the folding process.
6.5 Improved hole-arrangement schemes
Based on the parameter study, I proposed three improved hole arrangements: staggered holes, impact-end-focused holes, and gradually increasing hole diameters. The staggered hole pattern produced shear fracture and had the lowest specific energy absorption. The impact-end-focused arrangement did not change the peak force but increased the specific energy absorption by 4.51% compared with the original uniform three-row pattern.
The most effective scheme was the increasing-diameter arrangement. In this design, the hole radius at the fixed end was 1 mm, and the hole radius increased by 0.5 mm for each row toward the impact end. The wall thickness was 1.5 mm. This arrangement forced the impact-end rows to collapse first, creating a stable folding wave front. Compared with the uniform baseline, the increasing-diameter tube improved the specific energy absorption by 40.8% while reducing the average crushing force. Table 10 summarises the performance of the different schemes.
| Scheme | \(F_{\max}\) / kN | \(SEA\) / J·g⁻¹ | \(F_c\) / kN | Collapse mode |
|---|---|---|---|---|
| Staggered holes | 8.39 | 32.56 | 4.63 | Incomplete |
| Impact-end focused | 9.24 | 47.70 | 5.39 | Axisymmetric |
| Increasing diameter | 8.41 | 44.40 | 9.13 | Axisymmetric |
| Baseline \(t=1,r=1.5\) | 9.22 | 45.64 | 5.85 | Axisymmetric |
| Baseline \(t=1.5,r=1.5\) | 19.20 | 31.65 | 13.68 | Global |
| Baseline \(t=1.5,r=2.5\) | 13.68 | 33.19 | 11.44 | Axisymmetric |
6.6 Experimental verification on solar inverters
The optimised increasing-diameter thin-walled tube was then installed on the connection supports of the solar inverter enclosure. The wall thickness was 1.5 mm, the fixed-end hole diameter was 1 mm, and the hole diameters increased toward the impact end. I repeated the same explosion test with 4.6% propane and 5 J ignition energy. This time, the cover did not fly off. The thin-walled tubes were fully crushed, while the bolts and cover supports remained intact. The cover was deformed only slightly.
The energy analysis after the optimisation is presented in Table 11. The thin-walled tubes absorbed 72.78% of the total initial energy, while the cover absorbed only 19.93% and the bolts only 2.26%. This represents a dramatic improvement compared with the original enclosure, where the cover absorbed 78.8% of the energy. The induced-hole tubes protected the cover from severe plastic deformation and prevented the dangerous ejection of the cover and bolts.
| Component | Initial energy / J | Absorbed energy / J | Energy percentage |
|---|---|---|---|
| Cover | 518.3 | 103.3 | 19.93% |
| Bolts | 0 | 11.73 | 2.26% |
| Cover supports | 0 | 20.40 | 3.94% |
| Gaskets | 0 | 0.10 | 0.06% |
| Housing | 0 | 5.37 | 1.03% |
| Thin-walled tube | 0 | 377.50 | 72.78% |
The improved design does not require any change to the external geometry of the solar inverter. It can be retrofitted by simply replacing the standard connection supports with the new energy-absorbing tubes. The manufacturing cost is low, and the installation process is similar to that of ordinary bolts. This makes the solution highly suitable for existing products without requiring a complete redesign.
7. Conclusion
In this research, I systematically studied the explosion resistance of solar inverters under internal gas explosions. The main conclusions can be summarised as follows.
First, the maximum explosion load in a solar inverter is not produced by the stoichiometric propane concentration. The optimum concentration was 4.6% by volume, which is about 1.15 times the stoichiometric value. Internal obstacles and obstacle spacing significantly increase the blast pressure. A blockage ratio of about 50% and a spacing of about 200–300 mm provided the strongest flame acceleration. Ignition at the bottom-centre of the enclosure, where the flame has sufficient distance to develop before reaching the cover, produced the highest pressure. Higher ignition energy also increased the peak pressure, while a higher initial ambient temperature decreased the peak pressure because of the reduced gas density.
Second, the dynamic response of the solar inverter enclosure under blast load can be divided into three stages: load–structure interaction, plastic deformation of load-carrying members, and fracture separation. In the original design, the cover and bolts absorbed more than 85% of the total energy and failed in a brittle manner, leading to dangerous projectile formation.
Third, the introduction of induced-hole thin-walled circular tubes is an effective way to improve the blast resistance of solar inverters. The hole-row number, wall thickness, hole radius, and impact velocity all have important effects on the deformation mode. The increasing-diameter hole arrangement manufactured with a wall thickness of 1.5 mm, a fixed-end hole diameter of 1 mm, and a gradually increasing hole diameter was the optimum configuration. It improved the specific energy absorption by 40.8% compared with the uniform baseline.
Finally, the application of the optimised thin-walled tube to a complete solar inverter enclosure was experimentally verified. The cover no longer flew off, and the energy absorbed by the thin-walled tubes reached 72.78% of the total input. The cover energy absorption was reduced from 78.8% to 19.93%, and the bolt energy absorption was reduced from 6.5% to 2.26%. The proposed solution is a low-cost, reliable, and easily applied anti-explosion technique for existing solar inverters.
The results of this work provide useful guidance for the future anti-explosion design of solar inverters and other power-conversion equipment. Future studies could focus on multi-component fuel mixtures, the detailed coupling between internal explosions and structural deformation, and the effect of additional electronic components on flame acceleration. Furthermore, the same energy-absorbing concept could be extended to battery energy-storage cabinets and other confined electronic enclosures where internal explosions are a realistic hazard.