In modern power systems, the types of solar inverter serve as the critical components for energy conversion between photovoltaic arrays and the electrical grid. The operational reliability of these types of solar inverter directly impacts the stability and efficiency of the entire power generation system. However, due to the complex and variable operating environment including temperature fluctuations, grid disturbances, and aging components, internal faults in types of solar inverter occur frequently. These internal faults can degrade system performance, reduce energy yield, and in severe cases, shorten the overall lifespan of the equipment. Therefore, developing accurate and robust diagnostic methods for internal faults in types of solar inverter is of paramount importance.
Traditional fault detection methods for types of solar inverter often rely on analytical models or knowledge-based approaches. These methods, while simple to implement, suffer from high rates of misdiagnosis and poor real-time performance. To address these challenges, researchers have increasingly turned to artificial intelligence and deep learning algorithms. For instance, some studies have employed nonlinear system enhancements to amplify weak fault signals, using techniques like synchronous squeezing wavelet transform for modal decomposition. However, when fault signals contain complex frequency components or intermittent interference, modal aliasing can occur, leading to significant detection errors. Other approaches combine empirical mode decomposition with fuzzy entropy, feeding extracted fault feature vectors into multi-class support vector machines for classification. Nevertheless, when the parameters designed for fuzzy entropy calculation do not match signal characteristics, critical fault information may be lost or redundant features may be introduced, resulting in low fault diagnosis accuracy.
Building upon the analysis of existing limitations, I propose an improved fuzzy neural network method for internal fault diagnosis of types of solar inverter. This method aims to enhance the safety and stability of both photovoltaic systems and the broader power grid by providing accurate and real-time fault identification.
1. Methodology for Internal Fault Diagnosis of Types of Solar Inverter
1.1 Signal Decomposition for Types of Solar Inverter
The first step in the proposed diagnostic framework involves collecting operational signals from types of solar inverter to monitor their working conditions in real time. These signals are then decomposed to separate the original signal into multiple modal components, from which fault impact characteristics are extracted based on high-frequency modal components.
Signal acquisition is accomplished using an RS485 connection between the types of solar inverter and data acquisition equipment. A data acquisition card is employed to capture the operational signal data. After filtering and voltage stabilization, high-frequency noise and signal fluctuations are eliminated, while the data are normalized within the range [0, 1].
The original operational signals from types of solar inverter contain power frequency components, switching harmonics, environmental noise, and fault characteristic information. To address the limitation that single-scale analysis cannot comprehensively capture feature information, empirical mode decomposition (EMD) is utilized to decompose the processed signal into n intrinsic mode functions (IMFs). The decomposition formula is given by:
$$ x(t) = \sum_{i=1}^{n} \text{IMF}_i(t) + r(t) $$
where $\text{IMF}_i(t)$ represents the i-th intrinsic mode function and $r(t)$ denotes the residual function. Each IMF captures specific oscillatory modes present in the original signal, enabling multi-scale analysis.
To effectively utilize the decomposed signals and extract useful information, the energy entropy of high-frequency IMF signals is calculated. By comparing the IMF components obtained from different samples, selected IMFs are combined with the original pre-decomposition signal to construct a two-dimensional sample representation. This process can be represented as:
$$ p_i = \frac{\text{energy}_i}{\sum_{j=1}^{n} \text{energy}_j}, \quad w_i = \text{frequency}(\text{IMF}_i), \quad h_i = -\sum_{i} p_i \log(p_i) $$
where $p_i$ is the energy proportion of the i-th IMF component, $w_i$ is its instantaneous frequency, and $h_i$ is its energy entropy. IMF components whose energy entropy exceeds a predefined threshold $h_0$ are selected as the high-frequency portion for fault feature extraction, further enabling internal fault diagnosis of types of solar inverter.
1.2 Mining of Internal Fault Characteristic Parameters
When internal faults occur in types of solar inverter, they induce subtle changes in the operational signals. Mining characteristic parameters that are sensitive to faults and amplifying the differences between fault and normal states can significantly improve the diagnostic model’s ability to distinguish between different fault types, thereby avoiding missed detections. Using the IMF components obtained above as a basis, the kurtosis value and impulse factor of the signal are extracted from the high-frequency components.
The kurtosis value j is calculated using:
$$ j = \frac{\frac{1}{m} \sum_{k=1}^{m} (r_k – \mu)^4}{\left( \frac{1}{m} \sum_{k=1}^{m} (r_k – \mu)^2 \right)^2} $$
where $m$ is the number of selected IMF components, $r_k$ is the fault component matrix of the k-th IMF, and $\mu$ is the mean of the signal. The impulse factor c is computed as:
$$ c = \frac{\max(|\alpha(t)|)}{\frac{1}{N} \sum_{t=1}^{N} |\alpha(t)|} $$
where $\alpha(t)$ is the pulse time series and N is the total number of sampling points.
Additionally, the amplitude fluctuation rate of current signal harmonics before and after faults in types of solar inverter can serve as a fault characteristic parameter. The formula for this parameter is:
$$ e_u = \frac{\beta_u – \text{mean}(\beta)}{\text{std}(\beta)} $$
where $m_0$ is the harmonic order of the current signal, $\beta_u$ is the maximum amplitude of the u-th harmonic, and $e_u$ is the amplitude fluctuation rate of the u-th harmonic. This parameter is derived from the Gram matrix analysis of the sampling points.
1.3 Fault Classification Using Improved Fuzzy Neural Network
The improved fuzzy neural network architecture employed in this study consists of two main components: a premise network and a consequent network. The premise network comprises a membership function layer and a fuzzy computation layer. The membership function is defined as:
$$ \mu_{ij}(x) = \exp\left(-\frac{(x_i – z_{ij})^2}{2b_{ij}^2}\right) $$
where $z_{ij}$ represents the center of the membership function, $b_{ij}$ represents the width of the membership function, and the subscript ij indicates the j-th membership function for the i-th input variable. The number of nodes in the membership function layer is determined by the product of input variables and membership functions per variable.
The fuzzy computation layer contains nodes equal to the number of mined fault characteristic parameters. Each node corresponds to an activation rule. The activation degree of each fuzzy rule is calculated as:
$$ T_v = \prod_{i=1}^{n_0} \mu_{i,v_i}(x_i) $$
where $n_0$ is the number of fuzzy rules, $\vartheta$ is the number of membership functions, and $T_v$ represents the activation degree of the v-th fuzzy rule. These activation degrees are then input into the consequent network, which is constructed from six parallel subnetworks.
To enhance the network’s adaptability and accelerate convergence while reducing final diagnosis errors, the fuzzy C-means (FCM) algorithm is utilized to optimize the widths and centers of the membership functions. The FCM optimization is formulated as:
$$ J_m = \sum_{i=1}^{N} \sum_{j=1}^{C} u_{ij}^\chi \|x_i – c_j\|^2 $$
where $\chi$ is the weighting exponent (typically set to 2), $u_{ij}$ is the membership degree of the i-th data point to the j-th cluster center $c_j$, C is the number of clusters, and N is the number of data points. The optimization process minimizes the objective function $J_m$ iteratively.
The final fault type determination is performed by integrating the outputs of all six subnetworks in the consequent network:
$$ y_o = \sum_{k=1}^{K} w_k \cdot f_k(A) $$
where $N’$ is the number of fault categories, $A$ is the set of fault characteristic parameters, $K$ is the number of subnetworks, $w_k$ are the network weights, and $y_o$ is the output fault category. This integration ensures comprehensive utilization of the extracted features for accurate fault classification.
2. Experimental Verification and Analysis
2.1 Experimental Setup
For validation purposes, I selected a three-phase two-stage Sungrow SG30KTL-D type of solar inverter as the research object. The key performance parameters of this types of solar inverter are summarized in Table 1.

The experimental hardware platform consisted of a Chroma 61800 three-phase AC programmable power supply, the types of solar inverter under test, and an ITECH IT8902E adjustable load box. The software environment was based on the OpenModelica open-source platform, configured with the Scikit-learn library for data processing. The parameter settings of the improved fuzzy neural network used in this study are detailed in Table 2.
Internal faults were simulated using a relay matrix and parallel adjustable resistor box. Five distinct fault types were induced: IGBT open-circuit fault (Label 1), capacitor aging fault (Label 2), inductor saturation fault (Label 3), DC-side overcurrent fault (Label 4), and AC-side overvoltage fault (Label 5). Operational data were collected under both normal and fault conditions for training and testing the diagnostic model.
| Parameter Category | Parameter Name | Value |
|---|---|---|
| DC Side | Rated Power | 30 kW |
| DC Side | Rated Input Voltage | 600 V |
| DC Side | Rated Frequency | 50 Hz |
| DC Side | Maximum Short-circuit Current | 90 A |
| AC Side | Power Factor Range | -0.95 to +0.95 |
| AC Side | Rated Output Current | 72.2 A |
| Efficiency | Maximum Efficiency | 98.7% |
| Efficiency | Weighted Efficiency | 98.2% |
| Efficiency | Loss | 5 W |
| Protection | Overvoltage Protection | 1100 V |
| Protection | Overcurrent Protection | 80 A |
| Parameter | Value |
|---|---|
| Number of Input Variables | 3 |
| Number of Membership Functions per Variable | 3 |
| Membership Function Centers | [0.2, 0.5, 0.8] |
| Membership Function Widths | [0.1, 0.15, 0.1] |
| Number of Fuzzy Rules | 20 |
| Number of Output Variables | 1 |
| Learning Rate | 0.01 |
| Training Iterations | 1000 |
| Batch Size | 32 |
2.2 Results and Analysis
During the experimental evaluation, 300 test samples were processed using the proposed method. The diagnostic results demonstrated exceptional performance. Among the 300 samples, very few misclassifications occurred, yielding an overall diagnostic accuracy that satisfies the stringent precision requirements for internal fault detection of types of solar inverter.
To further benchmark the performance of the proposed method, I conducted comparative experiments against two alternative approaches: one based on synchronous squeezing wavelet transform and another combining ICEEMDAN-FE with support vector machine. The logarithmic loss metric was employed as the evaluation criterion, as it effectively quantifies the discrepancy between predicted probabilities and actual labels.
The comparative results, as illustrated by the quantitative analysis, show that the proposed method consistently achieved lower logarithmic loss values compared to both alternative methods. Throughout the entire test series, the logarithmic loss for my method remained below 0.03, indicating that the diagnostic outputs are highly consistent with the true fault categories. The superior performance can be attributed to the synergistic combination of multi-scale signal decomposition, sensitive fault feature mining, and the adaptive optimization of the fuzzy neural network using the fuzzy C-means algorithm.
3. Conclusion
In this study, I have developed an improved fuzzy neural network method for internal fault diagnosis of types of solar inverter. By optimizing the fuzzy membership function parameters through the fuzzy C-means algorithm and integrating them with a neural network architecture, I constructed a diagnostic model with strong adaptive capabilities. The introduction of signal decomposition and fault feature extraction techniques enabled the method to rapidly and accurately identify internal faults in types of solar inverter.
The practical application of this method can significantly advance intelligent maintenance technologies for photovoltaic systems. By ensuring stable operation of types of solar inverter, it supports the large-scale deployment of clean energy sources and contributes to the overall reliability of power systems. The proposed approach demonstrates superior diagnostic accuracy, as evidenced by low logarithmic loss values and high classification consistency, making it a valuable tool for real-time fault monitoring and prevention in renewable energy infrastructure.