A Novel Automated Control Method for Steady-State Error in Photovoltaic Grid-Connected Solar Inverters under Three-Phase Voltage Imbalance

As a researcher deeply engaged in the field of power system automation and renewable energy, I have been consistently challenged by the operational intricacies of photovoltaic grid-connected solar inverters. One of the most persistent issues that degrade the performance and stability of these inverters is the presence of three-phase voltage imbalance. This phenomenon, often caused by uneven load distribution, asymmetrical line impedances, or grid faults, can lead to significant steady-state errors in both the output voltage and current of the solar inverter. These errors not only compromise the quality of the power injected into the grid but also induce additional stress on the power electronic components of the solar inverter, potentially shortening its lifespan. To address these challenges, I designed an automated control method specifically tailored to minimize the steady-state error of photovoltaic grid-connected solar inverters operating under conditions of three-phase voltage imbalance.

My proposed method begins with a robust data acquisition and pre-processing stage. To construct a reliable steady-state model of the solar inverter, it is imperative to first obtain clean operational data. I employ a data acquisition system to collect raw data from the solar inverter during its operation. Recognizing that raw data often contains noise and outliers that can distort model accuracy, I applied a smoothing algorithm to the acquired time-series data. The smoothing process is mathematically defined by the following functions:

$$ \xi_1 = \psi \times \xi $$

$$ E(p) = \begin{cases} \frac{1}{3}(1 – p^3), & p < 1 \\ 0, & \text{else} \end{cases} $$

$$ s = t + kr + \lambda r^2 $$

Here, \(\xi_1\) represents the actual smoothed value, \(\psi\) is a random parameter, and \(\xi\) is the observed value of the operating parameters. The function \(E(p)\) is a weighting function, and \(s\) represents the smoothed curve derived from the fitting parameters \(t\), \(k\), and \(\lambda\) over the data points \(r\). This foundational step ensures that the subsequent modeling of the solar inverter’s behavior is based on high-fidelity information. On this basis, I then constructed the core steady-state function for the photovoltaic grid-connected solar inverter, explicitly incorporating the degree of three-phase voltage imbalance.

$$ k = \frac{|U_a – U_b| + |U_b – U_c| + |U_c – U_a|}{3|U_a|} $$

$$ M = \sum_{i=1}^{3} \frac{k I_i^2}{I_1} $$

In these equations, \(k\) is defined as the three-phase voltage imbalance factor. \(U_a, U_b, U_c\) represent the instantaneous voltages of phases A, B, and C of the solar inverter’s output. The variable \(M\) is the fundamental steady-state function I developed for the solar inverter, which is a function of the imbalance factor \(k\), the three-phase currents \(I_i\), and the output current \(I_1\). This function serves as the mathematical backbone for the entire control strategy, linking the operational state of the solar inverter directly to the grid’s voltage conditions.

With the steady-state function established, I proceeded to design the specific automated controller for the solar inverter’s steady-state error. This controller is designed with a focus on minimizing two primary targets: the output voltage steady-state error and the transmission current steady-state error. The overarching goal is to force both the output voltage and current of the solar inverter to closely track their respective reference values. After defining these control objectives, I architecture the controller structure. The controller operates through three main stages: optimization, prediction, and feedback. The core of the controller design lies in the calculation of its control parameters, which are derived from the input variables and the current state of the solar inverter.

$$ \beta_{ij} = \frac{\beta_{i|j} + \beta_{j|i}}{2n} $$

$$ \eta_{ij} = \frac{(1 + y_i – y_j^2)^{-1}}{\sum_{k \neq i} (1 + y_k – y_j^2)^{-1}} $$

$$ \beta_{i|j} = \frac{\exp\left(-\frac{|x_i – x_j|}{2\sigma_i^2}\right)}{\sum_{k \neq i} \exp\left(-\frac{|x_i – x_k|}{2\sigma_i^2}\right)} $$

Here, \(\beta_{ij}\) is a characteristic parameter of the control logic, and \(\eta_{ij}\) is a deviation parameter. The variables \(y_i, y_j, y_k, x_i, x_j, x_k\) represent different input signals to the controller, with \(n\) being the total number of inputs. The variance of the input variables is given by \(\sigma_i\). From these, the final control parameter \(z\) is calculated as:

$$ z = \sum_i \sum_j \beta_{ij} \log \beta_{ij} \eta_{ij} $$

This parameter \(z\) is crucial for the predictive capability of the controller. The predictive output \(G\) of the solar inverter controller is then defined:

$$ G = \frac{z \cdot w \cdot s + (h)}{[y_0 \cdot s + h]^2} $$

In this predictive formula, \(w\) is the current output of the solar inverter, \(y_0\) is the input variable value, \(s\) is a random constant, and \(h\) represents the time interval to the next prediction step. Combining these elements, I formulated the final expression for the photovoltaic grid-connected solar inverter steady-state error automation controller \(H\):

$$ H = G + \frac{2\lambda_1 \beta_{ij} \eta_{ij}}{z^2 + 2\lambda_2 z + h_1^2} $$

$$ h_1 = G + \frac{\lambda_3 z}{z + h_2} $$

Where \(\lambda_1\) and \(\lambda_2\) are weight parameters for different operating scenarios, \(h_1\) represents the control target, \(\lambda_3\) is a random parameter, and \(h_2\) is the transfer function of the input variable. This controller is the central intelligence of my proposed method, capable of calculating and predicting the optimal adjustments needed to minimize steady-state errors in the solar inverter.

The final step in my method is to generate and implement the specific control algorithm. This algorithm translates the output of the controller \(H\) into a concrete action plan for the solar inverter. The algorithm is formulated as:

$$ u(t) = k_1 \cdot e(t) + k_2 \cdot \sum e(t) + k_3 \cdot \frac{d e(t)}{dt} $$

Here, \(u(t)\) is the final control signal sent to the solar inverter, \(e(t)\) is the instantaneous error value for a given variable (voltage or current), \(\sum e(t)\) is the accumulated integral of the error, and the differential term \(\frac{de(t)}{dt}\) predicts future error trends. The parameters \(k_1, k_2, k_3\) are the weights for the proportional, integral, and derivative components of the control algorithm, respectively. This PID-like algorithm allows for fine-tuning of the control response. The controller iteratively adjusts these parameters based on real-time feedback from the solar inverter until the steady-state error is minimized to within an acceptable threshold.

Experimental Verification and Results

To validate the effectiveness of my proposed control method, I conducted a comprehensive series of experiments in a dedicated laboratory environment. The experimental setup was designed to simulate a realistic solar inverter system with the capability to introduce controlled three-phase voltage imbalances. The core equipment included a photovoltaic grid-connected solar inverter, a three-phase voltage imbalance generator, a data acquisition system, and digital controllers. The key experimental parameters used to set up the test bench are summarized in the following table:

Parameter Value
Rated Power of Solar Inverter 1000 W
Rated Voltage of Solar Inverter 22 V
Rated Current of Solar Inverter 42.3 A
Imbalance Generator Voltage 22 V
Imbalance Generator Current 42.3 A
Three-Phase Imbalance Ratio 1:1:1
Phase Difference 90 degrees
Imbalance Generator Frequency 50 Hz
Controller Sampling Frequency 15 kHz
Proportional Weight (\(k_1\)) 0.5
Integral Weight (\(k_2\)) 0.01
Derivative Weight (\(k_3\)) 0.001

In the first phase of testing, I evaluated the method’s primary objective: reducing the steady-state error of the solar inverter. I recorded the initial steady-state error of ten different solar inverter units under a standardized imbalance condition. I then applied my method (Method 1) to the solar inverters and recorded the residual steady-state error. For comparison, I also tested two other established control strategies: a method based on an adaptive feedback algorithm (Method 2) and a method using cross-layer design and filtering technology (Method 3). The results are presented in the following table:

Inverter Unit Initial Error (V) Method 1 Error (V) Method 2 Error (V) Method 3 Error (V)
#01 0.42 0.12 0.31 0.38
#02 0.43 0.13 0.32 0.39
#03 0.45 0.14 0.28 0.38
#04 0.44 0.14 0.31 0.39
#05 0.51 0.13 0.33 0.37
#06 0.48 0.12 0.34 0.39
#07 0.48 0.13 0.35 0.36
#08 0.47 0.12 0.36 0.38
#09 0.46 0.11 0.32 0.39
#10 0.42 0.12 0.31 0.38

The data clearly demonstrates the superior performance of my method. Across all ten solar inverter units, Method 1 consistently reduced the steady-state error from an average of ~0.44 V to an average of ~0.13 V. In contrast, Method 2 only reduced the error to an average of ~0.32 V, and Method 3 to an average of ~0.38 V. This quantitative assessment confirms that my proposed control method is significantly more effective in suppressing steady-state errors in a solar inverter under three-phase imbalance conditions.

In the second phase of testing, I evaluated the robustness of the control methods against varying degrees of three-phase voltage imbalance. Robustness is a critical characteristic for any controller applied to a real-world solar inverter, as grid conditions are rarely static. I used the imbalance generator to systematically increase the level of voltage imbalance and measured the control method’s performance, specifically its ability to maintain a low error metric. The robustness metric was defined as the inverse of the error magnitude, meaning a higher value indicates greater robustness. The results are shown in the following table:

Imbalance Level (k) Method 1 Robustness Method 2 Robustness Method 3 Robustness
0.05 0.95 0.75 0.65
0.10 0.92 0.62 0.48
0.15 0.90 0.55 0.40
0.20 0.88 0.50 0.35
0.25 0.87 0.45 0.30
0.30 0.85 0.38 0.25

This table provides compelling evidence of the robustness of my proposed method. As the imbalance level ‘k’ increases from 0.05 to 0.30, Method 1’s robustness decreases only slightly, from 0.95 to 0.85. This indicates that the controller is highly stable and capable of maintaining control over the solar inverter even as grid conditions worsen. Conversely, Method 2 and Method 3 show a dramatic decline in robustness. Method 2’s robustness drops from 0.75 to 0.38, and Method 3’s even more precipitously from 0.65 to 0.25. These results highlight a major advantage of my method: its consistent and reliable performance across a wide and adverse operating range, which is critical for the practical and safe operation of any photovoltaic grid-connected solar inverter.

Conclusion

In this study, I have successfully developed and validated an automated control method specifically designed to minimize the steady-state error of photovoltaic grid-connected solar inverters operating under three-phase voltage imbalance. By constructing a steady-state function that directly incorporates the imbalance factor and designing a sophisticated automation controller with predictive capabilities, my method offers a robust and highly effective solution to a critical problem in solar power integration. The experimental results conclusively show that my method significantly outperforms existing techniques. It not only reduces the absolute steady-state error to a fraction of its initial value but also maintains a high degree of robustness against increasing levels of grid imbalance. This dual achievement of high precision and strong stability makes my proposed method a superior choice for ensuring the operational quality, efficiency, and longevity of photovoltaic grid-connected solar inverters in real-world, non-ideal grid environments.