1. Introduction
The dual challenges of energy scarcity and climate change represent critical obstacles to global sustainable development in the 21st century. The overreliance on fossil fuels has led to a continuous increase in atmospheric CO₂ concentrations, exacerbating the greenhouse effect. As of 2023, coal still accounts for more than one-third of global electricity generation, with CO₂ emissions from coal-fired power exceeding 65% of the total energy sector emissions. The transition towards renewable energy sources has become an imperative rather than an option. Among all renewable alternatives, solar energy stands out as the most accessible and abundant resource, with photovoltaic (PV) technology playing a pivotal role in the clean energy transition.
However, a significant technical challenge plagues the photovoltaic industry: the performance of solar panels is intrinsically linked to their operating temperature. Crystalline silicon solar cells, which dominate the market, exhibit a linear degradation in efficiency with increasing temperature. Typically, for every 1 °C rise in temperature, the electrical conversion efficiency of a solar panel decreases by approximately 0.5%. During operation, a solar panel converts less than 20% of incident solar radiation into electricity, with the remainder converted into heat, causing the panel temperature to rise significantly. This self-heating effect is particularly pronounced under high solar irradiance conditions, leading to reduced power output, accelerated aging of materials, and even permanent damage such as hot-spot formation.
Cooling strategies for solar panels have evolved considerably over the past decades. Active cooling methods, including forced air circulation, water spraying, and liquid cooling through microchannels, provide effective temperature control but require external energy input, thereby increasing the carbon footprint of the PV system. Passive cooling methods, such as natural convection, radiative cooling, and phase change material (PCM) integration, offer simpler structures and lower maintenance but typically deliver lower cooling capacities. The fundamental contradiction between cooling power and energy consumption remains a critical barrier to achieving carbon neutrality in the PV industry.
Evaporative cooling has emerged as a promising solution that bridges the gap between cooling efficacy and energy sustainability. By leveraging the high latent heat of vaporization of water, evaporative cooling can effectively dissipate heat from solar panels without external power consumption. When water evaporates, it absorbs approximately 2257 J g⁻¹ of heat from the surroundings, providing a powerful cooling effect. This principle has been successfully applied in various engineering applications, and recently, researchers have begun exploring its potential for thermal management of solar panels.
The integration of atmospheric water harvesting with evaporative cooling represents an innovative approach to address the water dependency issue inherent in traditional evaporative cooling systems. Hygroscopic materials, such as hydrogels loaded with hygroscopic salts, can absorb water vapor from the atmosphere during nighttime or idle periods and release it as liquid water. This stored water can then evaporate during daytime operation, absorbing heat from the solar panel and providing passive cooling. This self-sustaining cycle eliminates the need for external water supply, making it particularly suitable for arid and water-scarce regions.
In this study, I developed a lithium-rich highly absorbent hydrogel (LHAH) that combines atmospheric water harvesting with evaporative cooling for solar panel thermal management. The research encompasses material synthesis, characterization, performance evaluation, and system integration. The primary objective is to develop a green, efficient, and sustainable cooling strategy that can enhance the operational performance of solar panels while minimizing carbon footprint and water consumption.
2. Materials and Methods
2.1 Materials
The experimental materials used in this study are summarized in the following table, all with analytical grade purity unless otherwise specified:
| Material | Specification | Supplier |
|———-|————–|———-|
| Acrylamide (PAM) | Analytical grade | Aladdin Chemical Co., Ltd. |
| Carbon nanoparticles (CNs) | ~30 nm diameter | Aladdin Chemical Co., Ltd. |
| N,N’-Methylenebisacrylamide (MBAA) | Cross-linker | Aladdin Chemical Co., Ltd. |
| Tetramethylethylenediamine (TEMED) | Accelerator | Beijing Century Kechuang Technology |
| Potassium persulfate (KPS) | Initiator | Shanghai 3F New Materials Co., Ltd. |
| Lithium chloride (LiCl) | Analytical grade | Aladdin Chemical Co., Ltd. |
| Deionized water | Resistivity 18.2 MΩ·cm | Laboratory prepared |
2.2 Preparation of Lithium-Rich Highly Absorbent Hydrogel
The LHAH was prepared using an in-situ polymerization method followed by solution immersion. The detailed fabrication process is illustrated in the preparation flowchart. First, 2 g of PAM was dissolved in 10 mL of CNs dispersion under vigorous stirring. The mixture was ultrasonicated for 5 minutes to ensure uniform dispersion of CNs in the PAM solution. Subsequently, 10 mg of KPS (initiator) and 0.6 mg of MBAA (cross-linker) were added to the solution, followed by thorough mixing using a magnetic stirrer. Finally, 25 μL of TEMED was introduced to accelerate the polymerization reaction.
The mixed solution was then transferred to a Petri dish and allowed to stand for 12 hours, during which the polymerization reaction occurred, forming a PAM-CNs hydrogel matrix. The hydrogel was subsequently freeze-dried for 8 hours to create a porous internal structure. The freeze-drying process causes ice crystals to form and sublime, leaving behind a network of interconnected pores that facilitate water transport and storage.
The porous PAM-CNs hydrogel was then immersed in 30 mL of LiCl solutions with varying concentrations (0.1 to 0.6 g mL⁻¹) for 24 hours. This solution immersion method allowed LiCl particles to diffuse into the hydrogel network, leveraging the concentration gradient between the external solution and the internal aqueous phase. After immersion, the hydrogel was rinsed with deionized water to remove surface-adsorbed LiCl and dried in an oven at 80 °C for 12 hours to obtain the final dry LHAH.
The LiCl loading rate was calculated to optimize the salt concentration. The experimental results showed a clear non-monotonic relationship between LiCl concentration and loading efficiency:
| LiCl Concentration (g mL⁻¹) | Loading Rate (g g⁻¹) |
|——————————|———————-|
| 0.1 | 1.40 |
| 0.2 | 3.29 |
| 0.3 | 4.34 |
| 0.4 | 6.23 |
| 0.5 | 5.39 |
| 0.6 | 4.03 |
The optimal LiCl concentration was determined to be 0.4 g mL⁻¹, yielding a maximum loading rate of 6.23 g g⁻¹. This optimal concentration represents a balance between osmotic pressure driving force and diffusion kinetics. At lower concentrations, insufficient LiCl is available for loading, while at higher concentrations, rapid osmotic equilibrium can hinder effective ion diffusion into the hydrogel matrix.
2.3 Characterization Methods
The prepared LHAH was characterized using multiple analytical techniques to understand its structure, composition, and properties:
– **Scanning Electron Microscopy (SEM)**: Field-emission SEM (Sigma300, Zeiss) was employed to observe the surface morphology and cross-sectional structure of LHAH samples. The acceleration voltage was set to 5 kV, and the magnification ranged from ×12 to ×2,000,000.
– **Energy Dispersive Spectroscopy (EDS)**: Elemental mapping was performed to confirm the uniform distribution of key elements (C, N, O, Cl) within the hydrogel matrix.
– **X-ray Photoelectron Spectroscopy (XPS)**: An Escalab 250 Xi spectrometer was used to determine the surface chemical composition and elemental states.
– **X-ray Diffraction (XRD)**: A D8 ADVANCE diffractometer with Cu Kα radiation was used to analyze the crystal structure and phase composition.
– **Fourier Transform Infrared Spectroscopy (FTIR)**: An ALPHA II spectrometer was used to identify functional groups and chemical bonding.
– **Contact Angle Measurement**: The water contact angle was measured using an Attension Theta system to evaluate surface hydrophilicity and water absorption kinetics.
– **Thermal Conductivity Measurement**: A Netzsch LAF467 HyperFlash laser flash apparatus was used to measure the thermal diffusivity and calculate the thermal conductivity of the hydrogels.
– **Humidity Adsorption Testing**: A constant temperature-humidity chamber was used to provide controlled adsorption environments. Samples were placed in the chamber at specific relative humidity levels, and their weight change was monitored using a high-precision electronic balance (Practum 313-1CN, ±0.1 mg accuracy).
3. Characterization Results and Discussion
3.1 Morphology and Structure
SEM analysis revealed that LHAH possesses a well-defined porous structure. The average pore diameter was approximately 20 μm, with wall thickness of about 30 μm. Carbon nanoparticles were observed embedded on the polymer skeleton, creating a rough surface texture on the pore walls. This porosity is critical for providing storage space for atmospheric water and facilitating the escape of water vapor during evaporation.
The formation of pores can be attributed to the freeze-drying process, where ice crystals formed during freezing are removed by sublimation, leaving behind a porous network. The complete removal of ice crystals and the structural integrity of the hydrogel network confirm the successful formation of a stable porous structure.
EDS elemental mapping demonstrated the uniform distribution of carbon (green), nitrogen (yellow), oxygen (red), and chlorine (orange) throughout the sample. This homogeneous distribution confirms the effective loading of LiCl into the hydrogel matrix and the uniform dispersion of CNs, which are essential for the material’s hygroscopic and thermal properties.
3.2 Phase Composition and Chemical States
XRD patterns of PAM, PAM-CNs, PAM-LiCl, and LHAH revealed distinct differences among the samples. LHAH exhibited characteristic diffraction peaks at 2θ values of approximately 20°, 32°, and 47°, corresponding to the crystalline phases of PAM, LiCl, and graphitic carbon structures, respectively. The sharp diffraction peaks indicate good crystallinity of the LiCl phase within the hydrogel matrix, while the absence of unexpected peaks confirms the high phase purity of the composite material.
XPS analysis provided detailed surface chemical composition data. Key peaks corresponding to Li 1s (56 eV), Cl 2p (199 eV), O 1s (531 eV), C 1s (285 eV), and N 1s (399 eV) were clearly identified. The atomic concentrations of Cl and Li were determined to be 15.22% and 23.72%, respectively, confirming the significant loading of LiCl within the LHAH structure.
FTIR spectroscopy revealed important structural information. Compared to pure PAM, the LHAH spectrum showed a reduction in the C=O stretching vibration peak at 1656 cm⁻¹, which can be attributed to the interaction between CNs and the polymer chains. The presence of LiCl resulted in increased intensity of O-H stretching (3378 cm⁻¹) and H-O-H bending (1640 cm⁻¹) vibrations, indicating the formation of LiCl hydrates. Critically, no new chemical bonds were formed between LiCl and the polymer network, suggesting that LiCl exists primarily as free ions within the hydrogel’s aqueous phase.
3.3 Surface Wettability and Thermal Conductivity
Contact angle measurements demonstrated the exceptional hydrophilicity of LHAH. A 7.5 μL water droplet was completely absorbed by the LHAH surface within 0.16 seconds. This ultra-fast water absorption can be attributed to the combined effects of the porous structure and the strong hygroscopic nature of LiCl. The presence of LiCl creates additional polar (hydrophilic) groups on the surface, while the porous architecture provides capillary channels that facilitate rapid water infiltration.
Thermal conductivity measurements showed a remarkable enhancement with the incorporation of CNs:
| Material | Thermal Conductivity (W m⁻² K⁻¹) |
|———-|———————————–|
| PAM | 0.007 |
| LHAH | 0.402 |
The thermal conductivity of LHAH was measured to be 0.402 W m⁻² K⁻¹, which is approximately 60 times higher than that of pure PAM hydrogel (0.007 W m⁻² K⁻¹). This significant improvement is attributed to the formation of thermally conductive pathways by the embedded CNs, which facilitates efficient heat transfer across the hydrogel structure.
Mechanical tests revealed that LHAH possesses excellent flexibility and elasticity. The material could be bent, folded, twisted, and stretched to multiple times its original length without visible cracks or structural damage. Upon release, it rapidly recovered to its original shape. This mechanical robustness ensures that LHAH can be easily mounted on solar panels of various geometries and can withstand environmental stressors including wind loads, thermal expansion, and mechanical vibrations.
4. Humidity Adsorption Performance
4.1 Experimental Protocol
The adsorption performance of LHAH was evaluated under controlled constant-temperature and constant-humidity conditions. All adsorption experiments were conducted at 25 °C in a constant temperature-humidity chamber. The environmental relative humidity was set to three levels: 30%, 60%, and 90%. Before each experiment, LHAH samples were dried in an oven at 80 °C for 12 hours and weighed to establish the initial dry mass.
The mass change rate and water storage capacity were calculated using the following equations:
$$w_i = \frac{m_i – m_0}{m_0}$$
where $w_i$ represents the mass change rate, $m_i$ is the mass after adsorption for time $i$, and $m_0$ is the initial mass. The water storage capacity was calculated as:
$$w = m_1 – m_0$$
where $w$ is the saturated water storage, $m_1$ is the final mass, and $m_0$ is the initial mass.
During the adsorption experiments, mass measurements were taken at increasing intervals: every 5 minutes for the first 30 minutes, every 10 minutes for the next 30 minutes, every 30 minutes for the following 2 hours, and then hourly until the 10-hour mark was reached.
4.2 Adsorption Kinetics
The adsorption kinetics of LHAH under different relative humidity conditions are presented in the dynamic adsorption curves. At RH = 30%, the adsorption rate reached a peak within the first 2 hours, after which it gradually decreased as the hydrogel approached saturation. After 10 hours, the total adsorption reached 8.7 g, corresponding to 57% of the dry weight of LHAH.
At RH = 60%, the adsorption rate peaked at approximately 90 minutes, with the 10-hour adsorption reaching 14.5 g, equivalent to 84% of the dry weight. At the highest humidity level (RH = 90%), LHAH achieved an impressive 175% mass change rate, with water storage reaching 27.2 g.
The water storage capacity of LHAH under different RH conditions is presented in the following table:
| Relative Humidity (%) | Adsorption Rate (g g⁻¹) | Water Storage (g) |
|———————-|————————|——————-|
| 30% | 0.57 | 8.7 |
| 60% | 0.84 | 14.5 |
| 90% | 1.75 | 27.2 |
The adsorption rate and water storage capacity both increased with increasing relative humidity, which is consistent with the expected behavior of hygroscopic materials. The driving force for water vapor adsorption is the difference in water vapor pressure between the environment and the LiCl solution within the hydrogel. Higher environmental humidity increases this vapor pressure difference, enhancing the adsorption rate.
4.3 Environmental Stability
To evaluate the stability of internally stored water in LHAH, a saturated sample was exposed to a low-humidity laboratory environment for 7 days. During days 1-5, with ambient RH around 10%, the LHAH lost 6 g of mass with a 5 mm reduction in diameter. Interestingly, when the environmental humidity increased to 15% on day 6, the adsorption rate exceeded the evaporation rate, resulting in increases in both mass and diameter. A similar trend was observed on day 7.
This behavior demonstrates that LHAH maintains a dynamic equilibrium with its environment, continuously exchanging moisture even under low-humidity conditions. The surface of LHAH remained consistently moist throughout the test, confirming its ability to maintain a hydrated state even in relatively dry environments. This property is critical for ensuring continuous evaporative cooling performance over extended periods.
5. Evaporative Cooling for Solar Panel Performance Enhancement
5.1 System Design and Operating Principle
Based on the exceptional properties of LHAH, I designed an evaporative cooling system for solar panel performance enhancement. The cooling system consists of three main components: a monocrystalline silicon solar panel (80 × 80 mm), the LHAH cooling material, and a channel-type cooling structure. The cooling channel was fabricated from acrylic plates and glass slides, with glass slides attached to the flat acrylic plate using thermally conductive adhesive to serve as support structures for the solar panel and hygroscopic material.
The operating principle of the cooling system is based on a cyclic adsorption-evaporation process. During daytime operation, solar radiation causes the temperature of the solar panel to rise. Since the water-saturated LHAH is fully attached to the back of the panel, heat from the solar panel is efficiently transferred to the LHAH through the back sheet. The stored water in LHAH utilizes this thermal energy to evaporate, with water vapor carrying away significant amounts of latent heat. The vapor is then dissipated to the environment through the channel structure, effectively cooling the solar panel.
The evaporation process is driven by the vapor pressure difference between the hydrogel surface and the surrounding environment. As the temperature of LHAH increases, the internal saturated vapor pressure rises, accelerating the evaporation rate. The high thermal conductivity of LHAH (0.402 W m⁻² K⁻¹) ensures efficient heat transfer from the solar panel to the evaporation sites within the hydrogel.
During nighttime or when the solar panel is not operating, LiCl in LHAH actively absorbs water vapor from the environment. The hygroscopic process begins with hydration of LiCl crystals, transitioning to deliquescence as more water is absorbed, eventually forming a LiCl solution within the hydrogel matrix. This continuous water adsorption regenerates the cooling capacity of LHAH, enabling a self-sustaining cooling cycle.
5.2 Experimental Setup
The experimental platform was constructed with the following components:
– **Solar Simulator**: A Class 3A solar simulator (CEL-HXF300-T3) served as the light source, with illumination intensity calibrated using a standard solar cell.
– **Temperature Measurement**: T-type thermocouples measured the backsheet temperature of the solar panel, with data collected using a 34972A data acquisition system.
– **Electrical Characterization**: An electrochemical workstation (PGSTA T302N) measured the output voltage and acquired I-V curves of the solar panel.
– **Thermal Imaging**: An infrared thermal camera (FLIR T250) monitored the surface temperature distribution.
– **Mass Tracking**: A high-precision electronic balance recorded the mass of LHAH at 10-second intervals.
Two devices were tested: Device 1 (experimental) with the LHAH cooling system, and Device 2 (control) without any cooling. All experiments were conducted under ambient conditions of 26 ± 0.5 °C and 15 ± 5% relative humidity.
The average cooling power of the evaporative LHAH was calculated using:
$$P = \frac{\Delta H_{vap} \times (m_2 – m_0)}{t \times A}$$
where $\Delta H_{vap}$ is the latent heat of vaporization of water (2257 J g⁻¹), $m_2$ and $m_0$ are the LHAH masses before and after evaporative cooling, $t$ is time, and $A$ is the surface area of LHAH (80 × 80 mm).
The maximum output power of the solar panel was calculated as:
$$P_{max} = U \times I$$
where $U$ and $I$ are the voltage and current at the maximum power point.
5.3 Temperature Reduction Performance
Infrared thermography analysis revealed significant temperature reductions for Device 1, which featured the LHAH cooling system. At 1.0 sun illumination, Device 2 (control) reached an average surface temperature of 70.2 °C, well above the optimal operating range for solar panels. In contrast, Device 1 achieved an average surface temperature of only 51.8 °C, corresponding to an 18.4 °C reduction.
Similar trends were observed at different illumination intensities. At 0.8 sun, Device 1 and Device 2 reached average temperatures of 48.9 °C and 63 °C, respectively. At 1.2 sun, Device 2 reached an extreme temperature of 78.2 °C, while Device 1 maintained a significantly cooler 53.7 °C — a 24 °C temperature difference.
The cooling performance exhibited a positive correlation with solar irradiance. This can be explained by the evaporation kinetics of water from the hydrogel. Higher irradiance leads to higher panel temperatures, which increases the saturated vapor pressure of water within LHAH, driving faster evaporation and providing more effective cooling.
Time-dependent temperature profiles further confirmed the effectiveness of the cooling system. In 1.0 sun, Device 1 reached a stable condition within 15 minutes at approximately 42 °C, gradually rising to 48 °C over the next 105 minutes. Device 2, without any cooling, continued to heat up throughout the experiment, reaching 78 °C. Under 0.8 and 1.2 sun, Device 1 showed similar trends, stabilizing at 47 °C and 52 °C, respectively.
The comparative analysis of temperature reduction achieved by various cooling technologies at 1.0 sun is presented in the table below:
| Cooling Method | Temperature Reduction (°C) |
|—————|—————————|
| Evaporative cooling (PAM-CNT-CaCl₂) | 14 |
| PCM cooling (OM35) | 12 |
| PCM cooling (palm wax) | 10 |
| Evaporative cooling (PAm/alginate-CaCl₂) | 8 |
| Radiative cooling (PDMS) | 11 |
| Radiative cooling (phosphor) | 13 |
| Immersion cooling (silicone oil) | 16 |
| Heat pipe cooling (water) | 20 |
| Cotton wick structure cooling | 15 |
| Nanofluid cooling (Al₂O₃-water) | 18 |
| **LHAH evaporative cooling (this work)** | **26** |
The LHAH-based evaporative cooling system demonstrated superior performance, achieving the highest temperature reduction of 26 °C among the compared technologies.
5.4 Cooling Power
The mass of LHAH decreased as water evaporated during the cooling process, providing a direct measure of the cooling power. At 0.8, 1.0, and 1.2 sun, the LHAH evaporated 6.7, 10.8, and 13.4 g of water over 2 hours, respectively. Using the latent heat of vaporization formula, the cooling power was calculated as:
| Irradiance (sun) | Evaporated Water (g) | Cooling Power (W m⁻²) |
|—————–|———————|———————-|
| 0.8 | 6.7 | 328 |
| 1.0 | 10.8 | 529 |
| 1.2 | 13.4 | 656 |
The cooling power increased with irradiance, reaching 529 W m⁻² at standard testing conditions (1.0 sun). This impressive cooling capacity is sufficient to maintain solar panels at near-optimal operating temperatures, thereby enhancing their electrical conversion efficiency.
5.5 Performance Enhancement of Solar Panels
The I-V characteristics of Device 1 and Device 2 were measured at different times during the 2-hour experiments. Both devices exhibited performance degradation over time as temperature rose, but the degradation was markedly slower for Device 1 with LHAH cooling. The enhanced performance stability of cooled solar panels was evident across all irradiance levels.
The open-circuit voltage (Voc) behavior showed characteristic temperature dependence:
| Irradiance | Device 1 Average Voc (V) | Device 2 Average Voc (V) | Voc Enhancement |
|———–|————————–|————————–|—————–|
| 0.8 sun | 7.0 | 6.7 | 4.8% |
| 1.0 sun | 6.7 | 6.3 | 6.2% |
| 1.2 sun | 6.6 | 6.1 | 7.9% |
At 1.0 sun, Device 2 experienced a rapid Voc drop from 7.12 V to 6.26 V within 15 minutes — a rate of 57.3 mV min⁻¹. In contrast, Device 1 declined from 7.2 V to 6.79 V over the same period, at a slower rate of 27.3 mV min⁻¹, maintaining an average Voc improvement of 7%.
The maximum power output (Pmax) also demonstrated the benefit of LHAH cooling:
| Irradiance | Device 1 Average Pmax (mW) | Device 2 Average Pmax (mW) | Pmax Enhancement |
|———–|—————————|—————————|—————–|
| 0.8 sun | 680 | 615 | 9.8% |
| 1.0 sun | 720 | 620 | 16.1% |
| 1.2 sun | 790 | 717 | 10.1% |
At 1.0 sun, Device 2 experienced a rapid Pmax decline from 695 mW to 592 mW within 15 minutes, followed by gradual deterioration. Device 1 showed a milder reduction from 784 mW to 707 mW over the same period, representing a 16.1% average improvement. The enhanced performance can be attributed to the lower operating temperature maintaining higher carrier mobility and a higher p-n junction barrier height.
The relationship between temperature and electrical performance follows:
$$\eta = \eta_{ref} \times [1 – \beta(T_c – T_{ref})]$$
where $\eta$ is the conversion efficiency, $\eta_{ref}$ is the reference efficiency, $\beta$ is the temperature coefficient (typically 0.004-0.005 °C⁻¹ for silicon cells), $T_c$ is the cell temperature, and $T_{ref}$ is the reference temperature (25 °C).
6. Self-Adaptive Cooling System for Solar Panel Operation
6.1 Environmental Passive Humidification Strategy
While LHAH demonstrated excellent performance in the open system, its adsorption efficiency remains dependent on ambient relative humidity, which limits its application in arid regions. To address this limitation, I proposed an environmental passive humidification method to enhance evaporative cooling, and designed a Self-Adaptive Cooling (SAC) system with multifunctional capabilities.
The SAC system comprises three main components: an evaporative cooling device, a condensation device, and a water collection device. The evaporative cooling device consists of LHAH with varying thicknesses attached to the backside of the solar panel. The condensation device is a box structure made of acrylic plates, connected to the evaporative cooling device through the LHAH evaporation chamber at the top. The water collection device is an open cube structure housing the evaporative cooling device and incorporated with a condensation water layer at the bottom.
The SAC system operates through three coupled processes: evaporation, condensation, and adsorption. The evaporative cooling device is positioned at the top of the system, with LHAH attached to the backsheet of the solar panel. During daytime, the solar panel absorbs solar radiation, and the heat is conducted to the hydrogel, driving water evaporation. The water vapor diffuses downward to the condensation chamber, where it condenses due to the temperature difference between the chamber and the ambient environment.
A cool-water layer in the condensation chamber serves dual purposes: acting as a cold source to promote vapor condensation, and collecting waste heat to enhance evaporation, thus providing a humid environment for the hydrogel. The evaporated water from the bottom layer, driven by the combined effects of panel waste heat and condensation heat release, maintains high humidity within the SAC system. Elevated humidity accelerates water adsorption by LHAH, extending the cooling cycle.
6.2 Effect of Hydrogel Thickness
LHAH samples of varying thickness (4, 6, 8, 10, and 12 mm) were prepared by adjusting the amount of precursor solution while maintaining constant concentration. The LiCl loading capacity was evaluated for each sample:
| Thickness (mm) | Dry Weight (g) | Weight after LiCl Loading (g) | LiCl Loading Rate (g g⁻¹) |
|—————-|—————|——————————-|—————————|
| 4 | 2.3 | 15 | 5.5 |
| 6 | 3.3 | 20 | 5.1 |
| 8 | 4.8 | 33 | 5.9 |
| 10 | 6.6 | 32 | 3.8 |
| 12 | 7.5 | 31 | 3.1 |
The 8 mm hydrogel exhibited the highest LiCl loading rate of 5.9 g g⁻¹, while thicker samples showed significantly reduced loading rates. This can be attributed to the increased diffusion resistance in thicker hydrogels, limiting the penetration of LiCl solution into the interior structure.
Adsorption performance tests at 60% RH showed that thinner hydrogels achieved faster adsorption kinetics. After 10 hours at 60% RH, the mass change rates were:
| Thickness (mm) | Adsorption Rate at 60% RH (g g⁻¹) | Adsorption Rate at 90% RH (g g⁻¹) |
|—————-|———————————-|———————————–|
| 4 | 1.06 | 1.74 |
| 6 | 0.85 | 1.21 |
| 8 | 0.59 | 0.85 |
| 10 | 0.56 | 0.81 |
| 12 | 0.43 | 0.62 |
While thinner hydrogels exhibited higher adsorption rates, the total water storage capacity of the 8 mm sample was optimal at 17.7 g and 25.5 g for 60% and 90% RH, respectively. Considering the overall water storage, mechanical strength, and water collection capacity, the 8 mm LHAH was selected as the optimal cooling material for further experiments.
6.3 Water Collection Performance
The water collection performance of different LHAH thicknesses was evaluated under 1.0 sun. Water vapor evaporated from the hydrogel condensed on the chamber walls and was collected in the water collection device. The water production after 2 hours was:
| Thickness (mm) | Collected Water (g) |
|—————-|——————-|
| 4 | 2.1 |
| 6 | 2.8 |
| 8 | 3.8 |
| 10 | 3.2 |
| 12 | 2.6 |
The 8 mm LHAH collected the maximum amount of water (3.8 g). Although thinner hydrogels exhibited higher adsorption rates per unit mass, their total water content when cut to match the solar panel size was limited by their smaller volume. The 8 mm sample provided an optimal balance between water storage capacity and efficient water transport.
To verify the stability of water collection, the 8 mm LHAH was subjected to five consecutive adsorption-desorption cycles. The sample showed consistent collection performance, maintaining water production of 3.8 ± 0.2 g per cycle. The structural integrity of the hydrogel remained intact after multiple cycles, confirming its durability. Conductivity analysis of the collected water yielded a value of 5.96 mS, indicating reasonably pure condensed water.
6.4 SAC System Humidity Control
Achieving high humidity within the SAC system is crucial for sustaining LHAH adsorption. I investigated the effects of different coverage configurations (no cover, full cover, half cover) and different bottom water volumes (0, 100, 200, and 400 mL) on system humidity.
For the fully covered configuration with no bottom water, the internal humidity remained below 50%. Adding water layers significantly increased humidity, with the 200 mL water layer producing the fastest humidity rise and reaching a maximum of 83%, stabilizing at 70% after 30 minutes. The 400 mL water layer exhibited the slowest humidity increase due to its higher heat capacity requiring more energy to evaporate water.
The uncovered configuration showed enhanced humidity compared to the covered system due to direct solar radiation reaching the water layer. The 100 mL and 200 mL water layers produced nearly identical humidity profiles in this configuration (curves overlapped after 5 minutes). The half-covered configuration showed intermediate behavior.
Based on these results, the optimal SAC system configuration was determined to be: 8 mm LHAH as the adsorption material, 200 mL water layer, and half-cover configuration.
6.5 SAC Adaptive Performance Test
The SAC system was tested at 1.0 sun for 6 hours, with three configurations compared:
– Experimental group: SAC system with 8 mm LHAH and 200 mL water layer
– Control group 1: LHAH only (200 mL water layer removed)
– Control group 2: No cooling
Surface temperature analysis from infrared thermography showed that Control group 2 reached an average surface temperature of 71.7 °C, while Control group 1 peaked at 63.5 °C before gradually declining to 61.8 °C. However, Control group 1 experienced a sudden temperature increase at 4 hours due to LHAH water depletion, rising to 64.5 °C by the end of the experiment. In contrast, the experimental group with SAC maintained stable temperatures around 59.6 °C throughout the entire 6-hour test, achieving a 10 °C temperature reduction compared to Control group 2.
Backsheet temperature measurements confirmed these findings. Control group 2 reached a stable temperature of 78 °C, while Control group 1 stabilized at 64 °C for the first 3 hours before rising to 66 °C. The SAC-equipped experimental group maintained a constant temperature of approximately 63 °C, representing a 15 °C reduction compared to the uncooled control.
Voltage output measurements over the 6-hour test period demonstrated the evolutionary advantage of the SAC system. Control group 2 showed the most rapid voltage decline, decreasing from 5.98 V to 5.12 V within 30 minutes and further to 5.04 V by 6 hours. Control group 1, with LHAH but without SAC, declined from 5.95 V to 5.39 V initially, gradually reaching 5.24 V by 6 hours.
The SAC experimental group maintained superior voltage output, declining from 6 V to 5.43 V rapidly, but then holding at 5.30 V, with a slight recovery to 5.33 V observed after 4 hours. This recovery is attributed to the enhanced adsorption of LHAH within the high-humidity environment of the SAC system, regenerating its cooling capacity. The overall output voltage improvement relative to Control group 2 was 0.29 V.
Open-circuit voltage (Voc) measurements displayed similar trends:
| Configuration | Initial Voc (V) | Final Voc (V) | Voc Decline Rate (V h⁻¹) | Average Voc Enhancement vs Control |
|————–|—————–|—————|————————-|————————————|
| Control 2 | 5.98 | 5.03 | 0.90 | — |
| Control 1 | 5.98 | 5.23 | 0.71 | 3.4% |
| SAC (Experimental) | 6.02 | 5.31 | 0.56 | 4.4% |
The SAC system enabled a 4.4% improvement in average Voc compared to the uncooled control, demonstrating its effectiveness in maintaining solar panel performance over extended periods.
7. Conclusions and Outlook
In this study, I successfully developed a lithium-rich highly absorbent hydrogel (LHAH) for evaporative cooling of solar panels, with the following key conclusions:
1. **Material Development**: The LHAH was prepared through in-situ polymerization combined with solution immersion. The material exhibited exceptional hydrophilicity, absorbing a 7.5 μL water droplet within 0.16 seconds. Incorporating carbon nanoparticles increased the thermal conductivity to 0.402 W m⁻² K⁻¹, approximately 60 times that of pure PAM hydrogel. The optimal LiCl concentration for loading was determined to be 0.4 g mL⁻¹, achieving a loading rate of 6.23 g g⁻¹.
2. **Adsorption Performance**: The adsorption rate of LHAH was strongly dependent on environmental humidity, with 10-hour adsorption rates of 0.57, 0.84, and 1.75 g g⁻¹ at 30%, 60%, and 90% RH, respectively. The material maintained stable hydration even in low-humidity environments, achieving equilibrium through simultaneous evaporation and adsorption.
3. **Solar Panel Cooling**: The LHAH-based evaporative cooling system achieved temperature reductions of 19, 26, and 30 °C at 0.8, 1.0, and 1.2 sun, respectively, corresponding to cooling powers of 328, 529, and 656 W m⁻². The cooling system effectively delayed performance degradation of solar panels, with average open-circuit voltage improvements of 4.8%, 6.2%, and 7.9% at different irradiance levels.
4. **Adaptive Cooling System**: The proposed environmental passive humidification strategy effectively addresses the humidity dependence of LHAH. The Self-Adaptive Cooling system with an 8 mm hydrogel and 200 mL water layer maintained stable cooling for 6 hours at 1.0 sun, achieving a 0.29 V output voltage improvement and 4.4% average open-circuit voltage enhancement compared to the uncooled control.
The findings of this research contribute to the development of sustainable cooling technologies for solar panels, particularly in arid and water-scarce regions. The integration of atmospheric water harvesting with evaporative cooling provides a pathway towards carbon-neutral solar panel operation. Future work should focus on scaling up the system, field testing under diverse environmental conditions, and comprehensive lifecycle analysis to evaluate the economic and environmental implications of the technology. Additionally, exploring the integration of SAC systems with building-integrated photovoltaics and investigating the potential for simultaneous clean water production and power generation could further expand the application scope of this technology.