Design and Implementation of a 5kW Off-Grid Solar Inverter

With the escalating global energy crisis and environmental degradation, the research and application of renewable energy sources have become increasingly critical. Solar photovoltaic (PV) systems represent one of the most promising technologies in this domain. These systems can be categorized into various types based on their operational configurations, including off-grid, grid-connected, and hybrid systems. Among these, off-grid systems are particularly vital for remote areas and standalone applications where grid access is limited. The inverter is a cornerstone component in PV systems, and its reliability and conversion efficiency are paramount for overall system performance and cost-effectiveness. In this paper, I present a comprehensive design and implementation of a 5kW off-grid solar inverter utilizing advanced digital signal processing (DSP) technology. The design addresses common limitations in existing products, such as poor real-time performance, bulkiness, and low output voltage accuracy, by incorporating a transformerless topology and sophisticated control strategies. This inverter is suitable for small-power applications, including off-grid PV systems and wind-solar hybrid systems, and features compact size, light weight, high output precision, excellent waveform quality, and intelligent monitoring via field bus.

Solar inverters come in various types, each tailored to specific needs. The primary types of solar inverters include off-grid, grid-connected, and hybrid inverters. Off-grid inverters operate independently of the utility grid, making them ideal for remote locations. Grid-connected inverters synchronize with the grid to feed excess power back, while hybrid inverters combine features of both, often incorporating energy storage. Understanding these types of solar inverters is essential for selecting the appropriate technology for a given application. In this work, I focus on the off-grid type, which is gaining traction due to initiatives like rooftop PV programs. The topology chosen for this design is a non-isolated two-stage inverter, also known as a Boost inverter, which offers advantages in efficiency and size reduction compared to isolated topologies.

Type of Solar Inverter Key Characteristics Typical Applications
Off-Grid Inverter Operates independently; requires battery storage; no grid connection Remote homes, rural electrification, standalone systems
Grid-Connected Inverter Synchronizes with grid; exports surplus power; no storage needed Urban installations, net metering systems
Hybrid Inverter Combines off-grid and grid-connected features; includes storage management Backup power, energy management systems

The overall structure of the 5kW off-grid solar inverter comprises two main parts: the primary circuit and the secondary circuit. The primary circuit includes an input filter circuit, a Boost converter, a full-bridge inverter, and an output LC filter. The secondary circuit consists of a TMS320F2812 DSP-based controller, signal detection circuits, human-machine interface, and communication modules. This division ensures efficient power processing and intelligent control. The primary circuit handles power conversion, while the secondary circuit manages real-time monitoring and adjustment. Below, I delve into the detailed hardware design and control strategies.

The input filter circuit is designed to minimize voltage ripple at the input stage, which is crucial for stable operation. Assuming the maximum power output is \( P_{\text{max}} = 5 \, \text{kW} \), the efficiency \( \eta = 0.95 \), and the switching frequency \( f_r = 18 \, \text{kHz} \), the energy provided by the input filter capacitor per switching cycle can be approximated as:

$$ W_{\text{in}} = \frac{P_{\text{max}}}{\eta f_r} $$

Substituting the values, \( W_{\text{in}} = \frac{5000}{0.95 \times 18000} \approx 0.2924 \, \text{J} \). For half-cycle analysis, the energy is derived considering the minimum input voltage \( V_{\text{in,min}} = 38.4 \, \text{V} \) and a voltage ripple \( \Delta V_{\text{in,min}} = 0.01 \times V_{\text{in,min}} = 0.384 \, \text{V} \). The capacitance required is calculated as:

$$ C = \frac{2 W_{\text{in,half}}}{V_{\text{in,min}}^2 – (V_{\text{in,min}} – \Delta V_{\text{in,min}})^2} $$

where \( W_{\text{in,half}} \) is the energy per half-cycle. Using empirical data, \( C \approx 4960 \, \mu\text{F} \). To reduce equivalent series resistance, five 1000 μF electrolytic capacitors are connected in parallel, each accompanied by a 6 μF CBB capacitor for high-frequency compensation.

The Boost converter stage elevates the input DC voltage to a level suitable for inversion. The circuit operates in continuous conduction mode (CCM) for better output quality. The critical inductance for CCM is given by:

$$ L_{\text{crit}} = \frac{V_{\text{in}} D (1-D)^2}{2 f_r I_{\text{out}}} $$

where \( D \) is the duty cycle. For a power of 100 W, \( L_{\text{crit}} \approx 1 \, \text{mH} \). The output capacitor value is determined to maintain voltage stability. With a target output of 420 V DC and a ripple voltage of 2.1 V (0.5% of DC voltage), the capacitance is:

$$ C_{\text{boost}} = \frac{I_{\text{out}} D}{f_r \Delta V_{\text{out}}} $$

Substituting values (e.g., \( D = 0.9 \)), \( C_{\text{boost}} \approx 1033 \, \mu\text{F} \). Three 470 μF electrolytic capacitors are used in parallel for redundancy.

Component Parameter Value
Input Filter Capacitor Capacitance 4960 μF
Boost Inductor Inductance 1 mH
Boost Output Capacitor Capacitance 1410 μF (3×470 μF)
Switching Frequency Frequency 18 kHz

The full-bridge inverter converts the boosted DC to AC using sinusoidal pulse width modulation (SPWM). The modulation strategy employs synchronous modulation for a 50 Hz output, as it offers better harmonic performance at this frequency. The SPWM signals are generated by the DSP, with dead-time insertion to prevent shoot-through in the IGBTs. The LC low-pass filter at the output attenuates high-frequency harmonics. The filter’s transfer function is:

$$ H(s) = \frac{1}{1 + s \frac{L}{R} + s^2 L C} $$

where the resonant angular frequency \( \omega_L = \frac{1}{\sqrt{L C}} \) and the damping coefficient \( \epsilon = \frac{1}{2R} \sqrt{\frac{L}{C}} \). The cutoff frequency is set to 1 kHz, one-tenth of the switching frequency, to effectively filter out harmonics. For a 5 kW inverter with output voltage 220 V AC and load resistance \( R_L \approx 9.68 \, \Omega \), the characteristic impedance \( R \) is chosen as 6 Ω. Using:

$$ f_c = \frac{1}{2\pi \sqrt{L C}} $$

and \( R = \sqrt{\frac{L}{C}} \), values of \( L = 1 \, \text{mH} \) and \( C = 10 \, \mu\text{F} \) yield \( f_c \approx 1592 \, \text{Hz} \), which is acceptable after adjustments.

The control strategy integrates PID control with closed-loop negative feedback to enhance stability and accuracy. The DSP continuously monitors input and output voltages and currents, adjusting PWM parameters in real-time. The SPWM pulse generation relies on the TMS320F2812’s event managers. The number of points per sine wave cycle for SPWM is calculated as:

$$ N = \frac{f_{\text{spwm}}}{f_{\text{sin}}} $$

where \( f_{\text{spwm}} = 18 \, \text{kHz} \) and \( f_{\text{sin}} = 50 \, \text{Hz} \), giving \( N = 360 \). The timer period register value for the DSP is derived from:

$$ T1PR = \frac{f_{\text{cpu}}}{HISCP \times TPST1 \times f_{\text{spwm}}} $$

With \( f_{\text{cpu}} = 150 \, \text{MHz} \), \( HISCP = 2 \), and \( TPST1 = 1 \), \( T1PR \approx 4166 \). The resulting output frequency error is negligible (0.008 Hz), meeting design requirements.

Software design involves SPWM control and A/D conversion interrupt routines. The SPWM program initializes the event manager, generates a sine table, and reloads compare registers via interrupts. The sine table is created using:

$$ \text{INPUT}[i] = \left( \sin\left( \frac{2\pi i}{N} \right) \times m + 1 \right) \times \frac{T1PR}{2} $$

for \( i = 0 \) to \( N-1 \), where \( m \) is the modulation index. The A/D conversion is triggered by event manager signals, and the interrupt service routine processes data using arithmetic mean filtering for accuracy. Flowcharts in the code ensure proper handling of comparisons and conversions.

Testing and validation of the assembled inverter demonstrate satisfactory performance. Steady-state operation shows output voltage between 216 V and 226 V RMS and frequency between 49.6 Hz and 50.5 Hz, adhering to standards. The waveform quality is high, with minimal distortion, confirming the efficacy of the design. This approach not only meets the demands of off-grid applications but also contributes to the advancement of renewable energy technologies by addressing key inefficiencies in existing types of solar inverters.

In conclusion, the 5kW off-grid solar inverter designed here leverages DSP technology for superior performance. The hardware design emphasizes compactness and efficiency, while the software ensures precise control. Future work could explore scalability and integration with smart grids. The versatility of this design makes it a viable solution for various off-grid scenarios, underscoring the importance of continuous innovation in the types of solar inverters available today.

Scroll to Top