The rapid adoption of energy storage batteries in grid-scale applications demands advanced sensing techniques to ensure operational safety and performance optimization. This study demonstrates a fiber Bragg grating (FBG)-based approach for real-time strain monitoring and state-of-charge (SOC) estimation in graphite-lithium iron phosphate (AG||LFP) pouch cells, revealing critical insights into electrochemical-mechanical coupling phenomena.

Fundamentals of FBG Sensing
The FBG sensing mechanism operates through wavelength modulation governed by:
$$
\lambda_B = 2n_{\text{eff}}\Lambda
$$
where $n_{\text{eff}}$ represents effective refractive index and $\Lambda$ denotes grating period. Temperature-strain decoupling follows:
$$
\begin{cases}
\Delta\lambda_{B1} = K_T\Delta T + K_\varepsilon\Delta\varepsilon \\
\Delta\lambda_{B2} = K_T\Delta T \\
\Delta\varepsilon = \frac{\Delta\lambda_{B1} – \Delta\lambda_{B2}}{K_\varepsilon}
\end{cases}
$$
| Parameter | Value | Error |
|---|---|---|
| Temperature coefficient ($K_T$) | 10.095 pm/°C | <0.5°C |
| Strain coefficient ($K_\varepsilon$) | 0.854 pm/με | <2.5 με |
Electrochemical-Mechanical Coupling
Energy storage batteries exhibit distinct strain evolution patterns during cycling:
$$
\varepsilon_{\text{total}} = \alpha_{\text{LFP}}\Delta SOC + \beta_{\text{AG}}\Delta SOC + \gamma_{\text{constraints}}
$$
Where $\alpha$ and $\beta$ represent electrode expansion coefficients, and $\gamma$ accounts for mechanical constraints.
| Component | Strain Range (με) | Phase Transition Points |
|---|---|---|
| LFP Cathode | 80-120 | Single plateau |
| AG Anode | 250-350 | 2L → 2 phase transition |
| Full Cell | 350-400 | Multi-stage evolution |
SOC Estimation Model
The piecewise linear regression model enables SOC prediction with <10% error:
$$
SOC =
\begin{cases}
0.15\varepsilon + 2.4 & \varepsilon \leq 120 \\
0.04\varepsilon + 14.2 & 120 < \varepsilon \leq 240 \\
0.18\varepsilon – 26.8 & 240 < \varepsilon \leq 320 \\
0.07\varepsilon + 6.4 & \varepsilon > 320
\end{cases}
$$
| SOC Range (%) | RMSE | R² |
|---|---|---|
| 0-25 | 8.7% | 0.89 |
| 25-75 | 4.2% | 0.96 |
| 75-100 | 6.9% | 0.91 |
Advanced Sensing Architecture
The H-shaped strain gauge configuration enhances measurement stability in energy storage batteries:
$$
Sensitivity = \frac{\Delta\lambda_B}{P} = 0.128\ \text{pm/kPa} \quad (R^2 = 0.998)
$$
where $P$ represents applied pressure and $\Delta\lambda_B$ denotes wavelength shift.
Operational Validation
Field testing demonstrates the FBG system’s capability in energy storage battery management:
$$
\text{Capacity Retention} = 1 – 0.0015N + 3.2\times10^{-6}\varepsilon_{\text{avg}}^2
$$
where $N$ represents cycle count and $\varepsilon_{\text{avg}}$ denotes average strain per cycle.
| Parameter | Cycle 50 | Cycle 100 | Cycle 200 |
|---|---|---|---|
| Strain Range (με) | 387±12 | 402±18 | 435±25 |
| Capacity Retention | 98.2% | 95.7% | 89.3% |
The integration of FBG sensing with energy storage battery management systems enables:
- Real-time mechanical health monitoring
- Early detection of lithium plating (Δε > 15% baseline)
- Non-invasive SOC estimation in flat voltage regions
- Cycle life prediction with <5% error
This optical sensing paradigm significantly enhances the safety and efficiency of grid-scale energy storage batteries while providing critical insights into degradation mechanisms. The technology demonstrates particular advantages in lithium iron phosphate systems where traditional voltage-based SOC estimation proves challenging.